After the 2016 Kyoung-Ju and 2017 Po-Hang earthquakes, securing seismic performance of non-structural elements as well as structural elements of buildings has become an important design issue in Korea. Suspended ceilings can cause damage to life and property to residents due to the falling of finishing materials or collapse of ceiling frame members during earthquakes, and in particular, it can cause secondary damage by blocking the evacuation route. According to KDS 41 17 00, if the ceiling area of the Seismic design category D building exceeds 250 m2, a seismic bracing system must be applied. This paper proposes a rigid bracing system to secure the seismic performance of the steel panel T-bar ceiling system, and evaluates the performance through the shake table test. Through experiments on two ceiling systems with different bracing arrangements, dynamic behaviors such as natural frequencies and relative displacements were analyzed, and the cause of panel separation during earthquakes was found. It was found that the relative displacement between the grid members was the biggest cause of panel detachment of the rigid braced ceiling system. In order to reduce the relative in-plane displacement of the ceiling, a method of narrowing the spacing between the braces or increasing the in-plane rigidity may be used.

Keywords

Acknowledgement

이 연구는 2021년도 국토교통부 도시건축 연구개발사업의 지원에 의한 결과의 일부임. 과제번호: 21AUDP-C146352-04

References

  1. American Society of Civil Engineers (ASCE) (2016), ASCE/SEI 7-16: Minimum Design Loads for Buildings and Other Structures, ASCE, Reston, VA, US.
  2. ASTM E580/E580M. (2017). "Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions." ASTM International.
  3. Brandolese, S., Fiorin, L. & Scotta, R. (2019). Seismic demand and capacity assessment of suspended ceiling systems. Engineering Structures. Vol.193.
  4. Gilani, A.S.J., Reinhorn, A.M., Glasgow, B., Lavan, O. & Miyamoto, H.K. (2010). Earthquake Simulator Testing and Seismic Evaluation of Suspended Ceilings. Journal of Architectural Engineering. Vol.16.
  5. Gilani A. S. J., Takhirov S. M., & Tedesco L. M. (2014). Proposed New approach for the seismic evaluation testing of suspended ceiling systems, 10th U.S. National Conference on Earthquake Engineering, 10NCEE, Anchorage, Alaska
  6. ICC Evaluation Service, LLC (ICC-ES) (2010). ICC-ES AC156, Acceptance criteria for seismic certification by shake-table testing of non-structural components and systems, International Code Council, Whittier, CA.
  7. KDS (2019). Seismic Design Code of Buildings (KDS 41 17 00: 2019), Korean Design Standard
  8. KS D 3609 (2015). Steel furrings for wall and ceiling in buildings
  9. Lee, J., In, S., Jung, D., Lee, D., Lee, S., & Cho, B. (2019). Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test, Journal of the Architectural Institute of Korea Structure & Construction. 35(10). 171
  10. Lee, J., Jung, D., Lee, D., & Cho, B. (2020). Performance Evaluation of Perimeter Reinforced T-bar Type Suspended Ceiling with Steel-Panel using Shaking Table Test, Journal of the Architectural Institute of Korea Structure & Construction. Vol.36 No.10.
  11. Recommendation for A seismic Design and Construction of Nonstructural Elements (2013). Architectural Institute of Japan, Japan