DOI QR코드

DOI QR Code

Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept

  • Hilin, Tas (Department of Prosthodontics, Faculty of Dentistry, Inonu University) ;
  • Fatih, Demirci (Department of Prosthodontics, Faculty of Dentistry, Inonu University) ;
  • Mesut, Tuzlali (Department of Prosthodontics, Faculty of Dentistry, Inonu University) ;
  • Erkan, Bahce (Department of Mechanical Engineering, Faculty of Engineering, Inonu University) ;
  • Guler Yildirim, Avcu (Department of Prosthodontics, Faculty of Dentistry, Okan University)
  • Received : 2022.08.05
  • Accepted : 2022.12.15
  • Published : 2022.12.31

Abstract

PURPOSE. The aim of this study is to compare the casts obtained by using conventional techniques and liquid crystal display (LCD) three-dimensional (3D) print techniques in the All-on-4 treatment concept of the edentulous mandibular jaw. MATERIALS AND METHODS. In this study, a completely edentulous mandibular acrylic cast (typodont) with bone-level implants placed with the Allon-4 technique served as a reference cast. In this typodont, impressions were taken with the conventional technique and dental stone casts were obtained. In addition, after scanning the acrylic cast in a dental laboratory scanner and obtaining the Standard Tessellation Language (STL) data, 3D printed casts were manufactured with a 3D printing device based on the design. The stone and 3D printed casts were scanned in the laboratory scanner and STL data were obtained, and then the interimplant distances were measured using Geomagic Control X v2020 (3D Systems, Rock Hill, SC, USA) analysis software (n = 60). The obtained data were statistically evaluated with one-way analysis of variance (ANOVA) and Tukey's pairwise comparison tests. RESULTS. As a result of the one-way ANOVA test, it was determined that the stone casts, 3D printed casts, and reference cast values in all distance intervals conformed to the normal distribution and these values had a significant difference among them in all distance intervals. In Tukey pairwise comparison test, significant differences were found between casts at all distance intervals. In all analyses, the level of significance was determined as .05. CONCLUSION. 3D printed casts obtained with a 3D LCD printing device can be an alternative to stone casts when implants are placed in edentulous jaws. [J Adv Prosthodont 2022;14:379-87]

Keywords

Acknowledgement

This study was supported by grant No. TDH-2021-2668 from Inonu University Scientific Research Projects Unit, Malatya, Turkey.

References

  1. Malo P, Rangert B, Nobre M. "All-on-Four" immediate-function concept with Branemark system implants for completely edentulous mandibles: a retrospective clinical study. Clin Implant Dent Relat Res 2003;5 Suppl 1:2-9. https://doi.org/10.1111/j.1708-8208.2003.tb00010.x
  2. Krekmanov L, Kahn M, Rangert B, Lindstrom H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. Int J Oral Maxillofac Implants 2000;15:405-14.
  3. Bevilacqua M, Tealdo T, Menini M, Pera F, Mossolov A, Drago C, Pera P. The influence of cantilever length and implant inclination on stress distribution in maxillary implant-supported fixed dentures. J Prosthet Dent 2011;105:5-13. https://doi.org/10.1016/S0022-3913(10)60182-5
  4. Malo P, de Araujo Nobre M, Lopes A, Ferro A, Botto J. The All-on-4 treatment concept for the rehabilitation of the completely edentulous mandible: A longitudinal study with 10 to 18 years of follow-up. Clin Implant Dent Relat Res 2019;21:565-77.
  5. Malo P, de Araujo Nobre M, Lopes A, Ferro A, Nunes M. The All-on-4 concept for full-arch rehabilitation of the edentulous maxillae: A longitudinal study with 5-13 years of follow-up. Clin Implant Dent Relat Res 2019; 21:538-49.
  6. Malo P, de Araujo Nobre M, Lopes A, Moss SM, Molina GJ. A longitudinal study of the survival of All-on-4 implants in the mandible with up to 10 years of follow-up. J Am Dent Assoc 2011;142:310-20. https://doi.org/10.14219/jada.archive.2011.0170
  7. Dawood A, Marti Marti B, Sauret-Jackson V, Darwood A. 3D printing in dentistry. Br Dent J 2015;219:521-9. https://doi.org/10.1038/sj.bdj.2015.914
  8. Moon W, Kim S, Lim BS, Park YS, Kim RJ, Chung SH. Dimensional accuracy evaluation of temporary dental restorations with different 3D printing systems. Materials (Basel) 2021;14:1487. https://doi.org/10.3390/ma14061487
  9. Zhang ZC, Li PL, Chu FT, Shen G. Influence of the three-dimensional printing technique and printing layer thickness on model accuracy. J Orofac Orthop 2019;80:194-204. https://doi.org/10.1007/s00056-019-00180-y
  10. Kim SY, Shin YS, Jung HD, Hwang CJ, Baik HS, Cha JY. Precision and trueness of dental models manufactured with different 3-dimensional printing techniques. Am J Orthod Dentofacial Orthop 2018;153: 144-53. https://doi.org/10.1016/j.ajodo.2017.05.025
  11. Favero CS, English JD, Cozad BE, Wirthlin JO, Short MM, Kasper FK. Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models. Am J Orthod Dentofacial Orthop 2017; 152:557-65. https://doi.org/10.1016/j.ajodo.2017.06.012
  12. Hazeveld A, Huddleston Slater JJ, Ren Y. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofacial Orthop 2014;145:108-15. https://doi.org/10.1016/j.ajodo.2013.05.011
  13. Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: a systematic review. J Prosthet Dent 2008;100:285-91. https://doi.org/10.1016/S0022-3913(08)60208-5
  14. Aljohani MS, Bukhari HA, Alshehri M, Alamoudi A. Accuracy of the different materials used to fabricate a verification jig of implant-supported fixed complete dental prostheses: An in vitro study. Cureus 2022;14: e29794.
  15. Fernandes DS, Anasane NS, Jagtap AK. Splinting open tray impression copings using long shank carbide burs during definitive impression: A dental technique. J Contemp Dent Pract 2022;23:566-8. https://doi.org/10.5005/jp-journals-10024-3318
  16. Lee H, Kwon KR, Paek J, Pae A, Noh K. A method for minimizing rotational errors of implant prostheses. Int J Oral Maxillofac Implants 2017;32:1018-22. https://doi.org/10.11607/jomi.5324
  17. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008;204:505-11. https://doi.org/10.1038/sj.bdj.2008.350
  18. Hong SJ, Lee H, Paek J, Pae A, Kim HS, Kwon KR, Noh K. Combining conventional impressions and intraoral scans: a technique for the treatment of complete denture patients with flabby tissue. J Prosthodont 2019; 28:592-5. https://doi.org/10.1111/jopr.13060
  19. Quaas S, Rudolph H, Luthardt RG. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 2007;35: 903-8. https://doi.org/10.1016/j.jdent.2007.08.008
  20. Zhang YJ, Shi JY, Qian SJ, Qiao SC, Lai HC. Accuracy of full-arch digital implant impressions taken using intraoral scanners and related variables: A systematic review. Int J Oral Implantol (Berl) 2021;14:157-79.
  21. Revilla-Leon M, Fogarty R, Barrington JJ, Zandinejad A, Ozcan M. Influence of scan body design and digital implant analogs on implant replica position in additively manufactured casts. J Prosthet Dent 2020;124: 202-10. https://doi.org/10.1016/j.prosdent.2019.07.011
  22. Lemos LS, Rebello IM, Vogel CJ, Barbosa MC. Reliability of measurements made on scanned cast models using the 3 Shape R 700 scanner. Dentomaxillofac Radiol 2015;44:20140337. https://doi.org/10.1259/dmfr.20140337
  23. Kumar A, Ghafoor H. Rapid prototyping: a future in orthodontics. J Orthod Res 2016;4:1-7. https://doi.org/10.4103/2321-3825.167856
  24. Wiranto MG, Engelbrecht WP, Tutein Nolthenius HE, van der Meer WJ, Ren Y. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod Dentofacial Orthop 2013;143:140-7. https://doi.org/10.1016/j.ajodo.2012.06.018
  25. Suese K. Progress in digital dentistry: The practical use of intraoral scanners. Dent Mater J 2020;39:52-56. https://doi.org/10.4012/dmj.2019-224
  26. Eckert SE, Koka S. Osseointegrated dental implants. The Bionic Human: Springer 2006. p. 603-18.
  27. Maxwell SK, Charles PH, Cassim N, Kairn T, Crowe SB. Assessing the fit of 3D printed bolus from CT, optical scanner and photogrammetry methods. Phys Eng Sci Med 2020;43:601-7. https://doi.org/10.1007/s13246-020-00861-8
  28. Mendricky R. Determination of measurement accuracy of optical 3D scanners. MM Sci J 2016:1565-72.
  29. Camardella LT, de Vasconcellos Vilella O, Breuning H. Accuracy of printed dental models made with 2 prototype technologies and different designs of model bases. Am J Orthod Dentofacial Orthop 2017;151:1178- 87. https://doi.org/10.1016/j.ajodo.2017.03.012
  30. Camardella LT, Vilella OV, van Hezel MM, Breuning KH. Accuracy of stereolithographically printed digital models compared to plaster models. J Orofac Orthop 2017;78:394-402. https://doi.org/10.1007/s00056-017-0093-1
  31. Bohner L, Hanisch M, De Luca Canto G, Mukai E, Sesma N, Neto PT. Accuracy of casts fabricated by digital and conventional implant impressions. J Oral Implantol 2019;45:94-9. https://doi.org/10.1563/aaid-joi-d-17-00142
  32. Nestler N, Wesemann C, Spies BC, Beuer F, Bumann A. Dimensional accuracy of extrusion- and photopolymerization-based 3D printers: In vitro study comparing printed casts. J Prosthet Dent 2021;125:103-10. https://doi.org/10.1016/j.prosdent.2019.11.011
  33. Papaspyridakos P, Chen YW, Alshawaf B, Kang K, Finkelman M, Chronopoulos V, Weber HP. Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans. J Prosthet Dent 2020;124:589-93. https://doi.org/10.1016/j.prosdent.2019.10.029
  34. Kim SY, Shin YS, Jung HD, Hwang CJ, Baik HS, Cha JY. Precision and trueness of dental models manufactured with different 3-dimensional printing techniques. Am J Orthod Dentofac 2018;153:144-53. https://doi.org/10.1016/j.ajodo.2017.05.025
  35. Kurtulmus-Yilmaz S, Ozan O, Ozcelik TB, Yagiz A. Digital evaluation of the accuracy of impression techniques and materials in angulated implants. J Dent 2014;42:1551-9. https://doi.org/10.1016/j.jdent.2014.10.008
  36. Lee SJ, Betensky RA, Gianneschi GE, Gallucci GO. Accuracy of digital versus conventional implant impressions. Clin Oral Implants Res 2015;26:715-9. https://doi.org/10.1111/clr.12375
  37. Papaspyridakos P, Benic GI, Hogsett VL, White GS, Lal K, Gallucci GO. Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study. Clin Oral Implants Res 2012;23:676-81. https://doi.org/10.1111/j.1600-0501.2011.02219.x
  38. Aly P, Mohsen C. Comparison of the accuracy of three-dimensional printed casts, digital, and conventional casts: an in vitro study. Eur J Dent 2020;14:189- 93. https://doi.org/10.1055/s-0040-1705243
  39. Amin S, Weber HP, Finkelman M, El Rafie K, Kudara Y, Papaspyridakos P. Digital vs. conventional full-arch implant impressions: a comparative study. Clin Oral Implants Res 2017;28:1360-7. https://doi.org/10.1111/clr.12994
  40. Gherlone E, Cappare P, Vinci R, Ferrini F, Gastaldi G, Crespi R. Conventional versus digital impressions for "All-on-Four" restorations. Int J Oral Maxillofac Implants 2016;31:324-30.
  41. Papaspyridakos P, Gallucci GO, Chen CJ, Hanssen S, Naert I, Vandenberghe B. Digital versus conventional implant impressions for edentulous patients: accuracy outcomes. Clin Oral Implants Res 2016;27:465-72.
  42. Kang MJ, Lim JH, Lee CG, Kim JE. Effects of post-curing light intensity on the mechanical properties and three-dimensional printing accuracy of interim dental material. Materials (Basel) 2022;15:6889. https://doi.org/10.3390/ma15196889
  43. Kasparova M, Grafova L, Dvorak P, Dostalova T, Prochazka A, Eliasova H, Prusa J, Kakawand S. Possibility of reconstruction of dental plaster cast from 3D digital study models. Biomed Eng Online 2013;12:49. https://doi.org/10.1186/1475-925X-12-49
  44. Kuhr F, Schmidt A, Rehmann P, Wostmann B. A new method for assessing the accuracy of full arch impressions in patients. J Dent 2016;55:68-74. https://doi.org/10.1016/j.jdent.2016.10.002
  45. Oliva B, Sferra S, Greco AL, Valente F, Grippaudo C. Three-dimensional analysis of dental arch forms in Italian population. Prog Orthod 2018;19:34. https://doi.org/10.1186/s40510-018-0233-1