DOI QR코드

DOI QR Code

Current Status and Appropriate Check Method of Construction Quality Control for Rebar Coupler Splice

철근 커플러이음의 시공품질 확인 현황 및 적정 시공품질 확인 방안

  • Received : 2022.10.17
  • Accepted : 2022.10.26
  • Published : 2022.12.20

Abstract

As buildings become taller, the strength of structural materials must increase and the amount of rebar reinforcement also increases while the application of an appropriate rebar splice method in the construction process become one of the essential factors. In this research, the current status of quality check for rebar coupler is identified by an expert questionnaire and an appropriate quality check method is proposed through a quality test on specimens similar to actual on-site construction. In the test results, it was revealed that, among the quality check methods for rebar coupler joints, the coupler tightening method and face to face degree of between upper and lower rebar did not affect the strength the specimen. Therefore, it is considered to be an appropriate way to check the coupler quality check to check whether the threads are completely assembled during on-site construction through manufacture the number of threads of rebar and coupler with a margin beyond the calculated thread number.

건물의 초고층화에 따라 구조재료의 강도 증가와 철근의 배근량이 증가할 뿐만 아니라 철근의 시공과정에서 적절한 이음방식의 사용이 필수적인 요소 중 하나이다. 본 연구에서는 철근 커플러이음의 시공품질 확인실태를 전문가 설문을 통해 파악하고, 실제 현장 시공과 유사한 시험체에 대한 품질시험을 통해 적정 품질 확인방안을 제시하고자 한다. 시험결과 설문조사 결과에서 나온 품질확인 방법 중 커플러 조임방법과 상하 두 철근의 맞댐 정도 등이 시험체 강도에 영향을 주지 않는다는 결과를 얻었다. 따라서 철근과 커플러의 나사산 개수를 계산치보다 여유를 두고 제작하고, 현장 시공시 나사산이 완전히 조립되었는지 확인하는 것이 적절한 커플러 품질 확인방법으로 사료된다.

Keywords

Acknowledgement

This work was supported by the National Research Foundation of Korea(NRF) grant funded by the Korea government (MOE)(No.2018R1D1A1B07045461).

References

  1. Ministry of Land, Infrastructure and Transport. Construction work quality management guidelines [Internet]. Seoul: Korea Law Information Center; c2015-2022 [updated 2021 Jan 18; cited 2022 Oct 15]. Available from: https://www.law.go.kr/LSW//admRulLsInfoP.do?chrClsCd=&admRulSeq=2100000208520
  2. Ministry of Land, Infrastructure and Transport. Construction work quality management guideline [Internet]. Seoul: Korea Law Information Center; c2015-2022 [updated 2020 Oct 13; cited 2022 Oct 15]. Available from: https://www.law.go.kr/LSW//admRulLsInfoP.do?chrClsCd=&admRulSeq=2100000193744
  3. KCS 14 20 11 Standard specification for concrete construction : rebar work. Seoul (Korea): Ministry of Land, Infrastructure and Transport; 2022. Korean.
  4. Rowell SP, Grey CE, Woodson SC, Hager KP. High strain-rate testing mechanical couplers. CA: US Army Corps of Engineers; 2009 Sep 65 p. Report No.: ADA508609
  5. Lee YJ, Lee JS, Lee WH, Lee YJ, Kim KH. Mechanical splice of SD600 and SD700 rebar. Magazine of the Korea Concrete Institute. 2015 May;27(3):24-7. https://doi.org/10.22636/MKCI.2015.27.3.24
  6. Bompa DV, Elghazouli AY. Inelastic cyclic behaviour of RC members incorporating threaded reinforcement couplers. Engineering Structures. 2019 Feb;180:468-83. https://doi.org/10.1016/j.engstruct.2018.11.053
  7. Dahal PK, Tazarv M. Mechanical bar splices for incorporation in plastic hinge regions of RC members. Construction and Building Materials. 2020 Oct;258:120308. https://doi.org/10.1016/j.conbuildmat.2020.120308
  8. Kheyroddin A, Dabiri H. Cyclic performance of RC beam-column joints with mechanical or forging (GPW) splices; an experimental study. Structures. 2020 Dec;28:2562-71. https://doi.org/10.1016/j.istruc.2020.10.071
  9. Dabiri H, Kheyroddin A, Asta AD. Splice methods used for reinforcement steel bars: A state-of-the-art review. Construction and Building Materials. 2022 Feb;320:126198. https://doi.org/10.1016/j.conbuildmat.2021.126198
  10. KS D 0249 Method of inspection for mechanical splicing joint of bars for concrete reinforcement. Seoul (Korea): Korea Agency for Technology and Standards; 2019. Korean.
  11. KS B 0802 Method of tensile test for metallic materials. Seoul (Korea): Korea Agency for Technology and Standards; 2018. Korean.
  12. KS D 3504 Steel bars for concrete reinforcement. Seoul (Korea): Korea Agency for Technology and Standards; 2021. Korean.
  13. KS D 3051 Dimensions, weight and tolerances of hot rolled steel bars and bar in coil. Seoul (Korea): Korea Agency for Technology and Standards; 2022. Korean.
  14. LM1501020106 Fastening element design. Seoul (Korea): Ministry of Education; 2021. Korean.
  15. In SR, Park MY. Tightening characteristics domestic M8 stainless screws. Journal of the Korea Vacum Society. 2001 Jul;10(2):155-63.
  16. Pasi B. What is factor of safety? Discuss various factors to be considered while selecting the factor of safety -Suggest various values for different type of loads and materials [Internet]. Maharashtra: Ques10; c2016-2022 [updated 2018 Feb ; cited 2022 Oct 17]. Ayailable from: https://www.ques10.com/p/21879/what-is-factor-of-safety-discuss-various-factors-t/
  17. Lee SS. Structural performance of horizontal connection using threaded rebarfor precast concrete wall panels. Journal of the Architectural Institute of Korea. 2021 Jul;37(7):175-82. https://doi.org/10.5659/JAIK.2021.37.7.175
  18. International Organization of Standardization. Mechanical properties of fasteners made of carbon steel and alloy steel, Part 1: Bolts, Screws and Studs with Specified Property Classes - Coarse Thread and Fine Pitch Thread (ISO 898-1:2009). Switzerland: ISO; 2009. 62 p.