과제정보
이 연구는 국토교통부 재원으로 국토교통과학기술진흥원의 건설교통기술 촉진연구과제의 지원으로 수행된 연구입니다 (Grant 21CTAP-C163815-01).
참고문헌
- Andrade, C., and Alonso, C. (2004), Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method, Materials and Structures, 37, 623-643. https://doi.org/10.1007/BF02483292
- Jang, B. S, Cha, H. Y., Ahn, J. H., and Kim, B.S. (2009), Case study of corrosion monitoring sensor for marine RC structure, Spring Conference of Korea Concrete Institute, 263-264.
- Kim, H. S., Lee, C. H., Moon, C. H., and Ahn, T. S. (2008), Application of long-term monitoring sensor for detection of steel corrosion in RC structure under marine environment, Conference of Korean Society of Civil Engineers, 10, 2645-2648.
- Kim, J. K., Kee, S.-H., Futalan, C. M. and Yee, J. J. (2020), Corrosion monitoring of reinforced steel embedded in cement mortar under wet-and-dry cycles by electrochemical impedance spectroscopy, Sensors, 20(1), 199.
- Kho, Y. T., (1999) The fundamentals of Corrosion and Anticorrosion, The Corrosion Science Society of Korea, 3-14.
- Macdonald, D. D. (2006), Reflections on the history of electrochemical impedance spectroscopy, Electrochimica Acta, 51, 1376-1388. https://doi.org/10.1016/j.electacta.2005.02.107
- Martin, M., Gebara, F. H., Strong, T. D., and Brown, R. B. (2009), A fully differential potentiostat, IEEE Sensors Journal, 9(2), 135-142. https://doi.org/10.1109/JSEN.2008.2011085
- Mehta, P. K. and Monteriro, P. J. M., (2003), Concrete: Microstructure, Properties, and Materials 4th Edition, McGraw Hill, 113-187.
- Montemor, M. F., Simoes, A. M. P., and Ferreira, M. G. S. (2003), Chloride- induced corrosion on reinforcing steel: From the fundamentals to the monitoring techniques, Cement and Concrete Composites, 25, 491-502. https://doi.org/10.1016/S0958-9465(02)00089-6
- Neville, A. M. (2011), Properties of Concrete 5th edition, Prentice Hall, 483-538.
- Nishikata, A., Zhu, Q., and Tada, E. (2014), Long-term monitoring of atmospheric corrosion at weathering steel bridges by an electrochemical impedance method, Corrosion Science, 87, 80-88. https://doi.org/10.1016/j.corsci.2014.06.007
- Pacheco-Torgal, F. (2018), Introduction. In Eco-Efficient Repair and Rehabilitation of Concrete Infrastructures, Elsevier, Amsterdam, The Netherlands, 1-12.
- Rodrigues, R., Gaboreau, S., Gance, J. Ignatiadis, I., and Betelu, S. (2021), Reinforced concrete structures: A review of corrosion mechanisms and advances in electrical methods for corrosion monitoring, Construction and Building Materials, 269, 121240. https://doi.org/10.1016/j.conbuildmat.2020.121240
- Ribeiro, D.V., and Abrantes, J. C. C. (2016), Application of electrochemical impedance spectroscopy (EIS) to monitor the corrosion of reinforced concrete: A new approach, Construction and Building Materials, 111, 98-104. https://doi.org/10.1016/j.conbuildmat.2016.02.047
- So, H.-S. (2006), Influence and assessment of corrosion rate of reinforcing bars using the linear polarization resistance technique, Journal of the Architectural Institute of Korea- Structure and Construction, 22(2), 107-114.
- Stern, M. and Geary, A.I. (1957), Electrochemical Polarization: I. A theoretical Analysis of the Shape of Polarization Curves, Journal of the Electrochemical Society, 104(1), 56-63. https://doi.org/10.1149/1.2428496
- Verma, S. K., Bhadauria, S. S., and Akhtar, S. (2013), Review of Nondestructive Testing Methods for Condition Monitoring of Concrete Structures, Journal of Construction Engineering, 834572.
- Yadav, A. P., Nishikata, A., and Tsuru, T. (2004), Electrochemical impedance study on galvanized steel corrosion under cyclic wet-dry conditions-influence of time of wetness, Corrosion Science, 46, 169-181. https://doi.org/10.1016/S0010-938X(03)00130-6