DOI QR코드

DOI QR Code

유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가

Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography

  • 정홍량 (한서대학교 방사선학과)
  • 투고 : 2021.09.28
  • 심사 : 2021.10.20
  • 발행 : 2021.10.31

초록

The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

키워드

과제정보

This study was supported by the 2021 University Research Support Project of Hanseo University

참고문헌

  1. Healthcare Bigdate Hub. Health Review & Assessment Service all nights reserve; 2018.
  2. Hwang SL, Jung HR, Lim CH. A Study on Radiation Dose for General Radiography Examination at First Medical Institution (Around the Radiology Clinic of National Capital Region). Journal of the Korean Society of Radiology. 2011;5(5):245-52. https://doi.org/10.7742/JKSR.2011.5.5.245
  3. The Korean Association for Radiation Protection. The 2007 Recommendations of the International Commission on Radiological Protection Publication 103; 2007.
  4. Kim JM, Lee IJ, Park JS, Yoo SM, Park JK, Jung HW, et al. Radiological Imaging Informatics. Sin Kwang; 2017.
  5. Ahn SM, Oh JH, Choi JH, Shin GS, Kim SC. Dose Change according to Diameter Change of the Cone for Dental X-ray Apparatus. The Journal of the Korea Contents Association. 2010;10(3):266-70. https://doi.org/10.5392/JKCA.2010.10.3.266
  6. Kang IS. Development and Usefulness Evaluation of IRIS type Collimator for Diagnostic Radiation Generator. Department of Health Care the Graduate School of Hanseo University; 2018.
  7. Kim KW, Min JW, Lyu KY, Kim JM, Jeong HW, Lee JA, et al. Comparison Study on CNR and SNR of Thoracic Spine Lateral Radiography. Journal of Radiological Science and Technology. 2013;36(4): 273-9.
  8. Ministry of Health and Welfare. Diagnostic Reference Level guidelines-General radiography; 2019.
  9. Kwon DM, Kim SS, Kim YK, Kim YI, Kim HT, Park YS, et al. Analog & Digital Medical Imaging Informatics. Dalhaks; 2001.
  10. The Korea Society of Medical Imaging Technology. Textbook of radiographic positioning and clinical diagnosis. Chung-Gu Publisher; 2020.
  11. Kim JS, Joo YC, Lee SK. Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Anteroposterior Radiography. Journal of Radiological Science and Technology. 2021;44(4):295-300. https://doi.org/10.17946/JRST.2021.44.4.295
  12. Choi SK. Change of the Scattered Dose by Field Size in X-ray Radiography. The Journal of the Korea Contents Association. 2013;13(3):198-203. https://doi.org/10.5392/JKCA.2013.13.03.198
  13. Jeon IK. Development and Usability Evaluation of Trapezoidal Cone in Diagnostic Radiation Generators. Department of Radiological Science the Graduate School of Hanseo University; 2020.
  14. Kang IS, Park JY, Choi JH, Lim CH, Jung HR. Usability Evaluation by Development of IRIS Type X-ray Collimator. Journal of Radiological Science and Technology. 2018;41(3):249-54. https://doi.org/10.17946/JRST.2018.41.3.249
  15. Kim KW, Son JH. Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom. Journal of Radiological Science and Technology. 2016;39(3):407-14. https://doi.org/10.17946/JRST.2016.39.3.15