DOI QR코드

DOI QR Code

Design and Fabrication of CLYC-Based Rotational Modulation Collimator (RMC) System for Gamma-Ray/Neutron Dual-Particle Imager

  • Kim, Hyun Suk (Division of Radiation Regulation, Korea Institute of Nuclear Safety (KINS)) ;
  • Lee, Jooyub (Department of Nuclear Engineering, Sejong University) ;
  • Choi, Sanghun (Division of Technology Planning Management, Korea Research Institute for defense Technology planning and advancement (KRIT)) ;
  • Bang, Young-bong (Transdisciplinary Department of Medicine and Advanced Technology, Seoul National University Hospital) ;
  • Ye, Sung-Joon (Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University) ;
  • Kim, Geehyun (Department of Nuclear Engineering, Seoul National University)
  • 투고 : 2021.06.14
  • 심사 : 2021.09.02
  • 발행 : 2021.09.30

초록

Background: This work aims to develop a new imaging system based on a pulse shape discrimination-capable Cs2LiYCl6:Ce (CLYC) scintillation detector combined with the rotational modulation collimator (RMC) technique for dual-particle imaging. Materials and Methods: In this study, a CLYC-based RMC system was designed based on Monte Carlo simulations, and a prototype was fabricated. Therein, a rotation control system was developed to rotate the RMC unit precisely, and a graphical user interface-based software was also developed to operate the data acquisition with RMC rotation. The RMC system was developed to allow combining various types of collimator masks and detectors interchangeably, making the imaging system more versatile for various applications and conditions. Results and Discussion: Operational performance of the fabricated system was studied by checking the accuracy and precision of the collimator rotation and obtaining modulation patterns from a gamma-ray source repeatedly. Conclusion: The prototype RMC system showed reliability in its mechanical properties and reproducibility in the acquisition of modulation patterns, and it will be further investigated for its dual-particle imaging capability with various complex radioactive source conditions.

키워드

과제정보

This work was supported by the Nuclear Safety Research Program through the Korea Foundation of Nuclear Safety (KOFONS), granted financial resource from the Nuclear Safety and Security Commission (NSSC), Republic of Korea (No. 1403024).

참고문헌

  1. Gmar M, Agelou M, Carrel F, Schoepff V. GAMPIX: a new generation of gamma camera. Nucl Instrum Methods Phys Res A. 2011;652(1):638-640. https://doi.org/10.1016/j.nima.2010.09.003
  2. Wahl CG, Kaye WR, Wang W, Zhang F, Jaworski JM, King A, et al. The Polaris-H imaging spectrometer. Nucl Instrum Methods Phys Res A. 2015;784:377-381. https://doi.org/10.1016/j.nima.2014.12.110
  3. Oda M. High-resolution x-ray collimator with broad field of view for astronomical use. Appl Opt. 1965:4(1):143. https://doi.org/10.1364/AO.4.000143
  4. Kowash BR, Wehe DK, Fessler JA. A rotating modulation imager for locating mid-range point sources. Nucl Instrum Methods Phys Res A. 2009;602(2):477-483. https://doi.org/10.1016/j.nima.2008.12.233
  5. Sharma AC, Tourassi GD, Kapadia AJ, Harrawood BP, Bender JE, Crowell AS, et al. Design and development of a high-energy gamma camera for use with NSECT imaging: feasibility for breast imaging. IEEE Trans Nucl Sci. 2007;54(5):1498-1505. https://doi.org/10.1109/TNS.2007.906058
  6. Kim HS, Ye SJ, Shin Y, Lee G, Kim G. Radiation imaging with a rotational modulation collimator (RMC) coupled to a Cs2LiYCl6:Ce (CLYC) detector. J Korean Phys Soc. 2016;69(11):1644-1650. https://doi.org/10.3938/jkps.69.1644
  7. Kim HS, Choi HY, Lee G, Ye SJ, Smith MB, Kim G. A Monte Carlo simulation study for the gamma-ray/neutron dual-particle imager using rotational modulation collimator (RMC). J Radiol Prot. 2018;38(1):299-309. https://doi.org/10.1088/1361-6498/aaa3c8
  8. Kim HS, Smith MB, Koslowsky MR, Kwak SW, Ye SJ, Kim G. Characterization of a CLYC detector and validation of the Monte Carlo simulation by measurement experiments. J Radiat Prot Res. 2017;42(1):48-55. https://doi.org/10.14407/jrpr.2017.42.1.48
  9. Kim C, Yeom JY, Kim G. Digital n-γ pulse shape discrimination in organic scintillators with a high-speed digitizer. J Radiat Prot Res. 2019;44(2):53-63. https://doi.org/10.14407/jrpr.2019.44.2.53
  10. Goorley T, James M, Booth T, Brown F, Bull J, Cox LJ, et al. Initial MCNP6 release overview. Nucl Technol. 2012;180(3):298-315. https://doi.org/10.13182/NT11-135
  11. Kim HS, Ye SJ, Lee G, Kim G. Optimization of the collimator mask for the rotational modulation collimator-based gamma-ray/neutron dual-particle imager. Curr Appl Phys. 2019;19(7):856-865. https://doi.org/10.1016/j.cap.2019.03.021
  12. Barros S, Kim G. Monte Carlo studies and response assessment of a new Rotational Modulation Collimator (RMC) design. J Radioanal Nucl Chem. 2018;316(3):1119-1128. https://doi.org/10.1007/s10967-018-5891-4
  13. Barros S, Kim G. Design modifications to Rotating Modulation Collimators for extended field-of-view. Appl Radiat Isot. 2021;170:109597. https://doi.org/10.1016/j.apradiso.2021.109597
  14. Jeong M, Van B, Wells BT, D'Aries LJ, Hammig MD. Scalable gamma-ray camera for wide-area search based on silicon photomultipliers array. Rev Sci Instrum. 2018;89(3):033106. https://doi.org/10.1063/1.5016563
  15. Jeong M, Hammig MD. Comparison of gamma ray localization using system matrixes obtained by either MCNP simulations or ray-driven calculations for a coded-aperture imaging system. Nucl Instrum Methods Phys Res A. 2020;954:161353. https://doi.org/10.1016/j.nima.2018.10.031
  16. Omata A, Kataoka J, Fujieda K, Sato S, Kuriyama E, Kato H, et al. Performance demonstration of a hybrid Compton camera with an active pinhole for wide-band X-ray and gamma-ray imaging. Sci Rep. 2020;10(1):14064. https://doi.org/10.1038/s41598-020-71019-5
  17. Lehner CE, He Z, Zhang F. 4π Compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood. IEEE Trans Nucl Sci. 2004;51(4):1618-1624. https://doi.org/10.1109/TNS.2004.832573
  18. Park S, Kim G, Lee G. Image reconstruction for rotational modulation collimator (RMC) using non local means (NLM) denoising filter. Nucl Instrum Methods Phys Res A. 2020;954:161901. https://doi.org/10.1016/j.nima.2019.02.028
  19. Shin Y, Kim G, Lee G. Improving image reconstruction algorithm for rotating modulation collimators using a variance stabilizing transform. J Instrum. 2017;12:C01051. https://doi.org/10.1088/1748-0221/12/01/C01051
  20. Shin Y, Kim G, Lee G. Regularizing RMC images for locating midrange point sources. J Instrum. 2016;11:C12007. https://doi.org/10.1088/1748-0221/11/12/C12007