Under the Korean Enforcement Decree of the Building Act, all of high story apartment houses more than 5 story buildings are mandate to install fire evacuation system to ensure safe evacuation from fire accident providing quick and easy bi-directional escape route when main entrance is blocked by flame and toxic smoke caused from fire. However, current fire evacuation system shows lack of understanding from residents and thus widely ignored for having insufficient safety functions especially on fire emergency. Studies found that recent changes in housing characteristics through improvement of living has lead applying various planes into dense and multipurpose floor space for convenient residence trend while conventional passive fire evacuation system such as indoor shelter space, light-weight partition and top-down emergency exit are still installed without improvement on fire safety which may cause unsuccessful evacuation especially when residential buildings are raising high. An alternative high rise building evacuation method, so the called escapable fire evacuation system has analyzed for safety evaluation compared with conventional passive stay able fire escape system that can bring efficient and safer solution providing high rise residents escape from fire accident. Evaluation for safety evacuation on active fire escape system has performed by Fire Dynamics Simulation and applying Pathfinder simulation, resulted in providing proper and appropriate escape route within the safety escape time allowed for multiple residents including disabled and elderly persons in high rise building fire.

Keywords

Acknowledgement

본 논문은 2021년도 동국대학교 연구년 지원에 의하여 이루어졌음

References

  1. Ahn, C. S., Yeo, I. H., An, J. H., & Cho, K. S. (2013). A study on the influence of temperature in evacuation space by fire door heat transfer, Proceeding of Korean Institute of Fire Science & Engineering Autumn Academic Conference:2013 Nov. 21: Seongnam(Korea) Seoul(Korea) : Korean Institute of Fire Science & Engineering: p.172-3
  2. Choi, K. C., Na, P., & Sul, Y. (2014). A Study on the Necessity of Introducing Evacuation Instrument in High-rise Buildings - Focusing on Elevator Type Evacuation Instrument, vol.28, no.3, p.10-18 https://doi.org/10.7731/KIFSE.2014.28.3.010
  3. Chu, H., Yu, J., Wen, J., Yi, M., & Chen, Y. (2019). Emergency evacuation simulation and management optimization in urban residential communities, Shanghai, China, p.6-25
  4. CTBUH Korea, The Korea Institute of Building Construction, Korean Institute of Fire Science & Engineering (2017). International Seminar on the Fire Risk and Safety Measures of High-rise Residential Buildings between Korea and Japan
  5. Hui, Z., & Chen, T. (2019). Experimental study of egress selection behavior between stairs and elevators during high-rise building evacuation, Institute of Public Safety Research Department of Engineering Physics, Tsinghua University, China, p8-22
  6. Hurley, M. J. (2016). SFPE Handbook of Fire Protection Engineering, Fifth Edition, Table A, p.38-39
  7. Jin, S. (2018). A Study on the Improvement of Night Fire Response Manual through Fire Frequency, Casualties, Property Damage Assessment, Fire Risk Analysis of Elderly Facilities and Site and Enquiry in accordance with ArcGIS Natural Classification Act, Hoseo University, Chung-nam, Korea
  8. Kim, K. (A member of the National Assembly) (2019). The Korea Institute of Architectural Policy, the Korea Architectural Design Association A forum "Strengthening the Effectiveness of Apartment Fire Evacuation", Seoul, Korea, p.12-35
  9. Kinateder, M., Kuligowaki, E., & Peacok, R. (2015). Risk perception in fire evacuation revisited: definitions related concepts, empirical evidence, Fire Science Reviews, p.2-26
  10. Korea Institute of Construction and Transportation Technology Evaluation, Editor-in-Chief (2008). Underground Space Environment Improvement and Disaster Prevention Technology Research Project, Chapter 3.1 Database guideline on combustion characteristic p.63-69
  11. Land & Housing Institute (2012). Unit Planning of LH Apartment Houses p.205
  12. Lee, W., & Lee, C. S. (2018). A Survey Study on the Learner's Recognition about the Descending Life Lines for the Fire Emergency Escaping Purpose. Vol.32, no.2, p.73-81 https://doi.org/10.7731/KIFSE.2018.32.2.073
  13. Lim, J. H. (2017). A Study on Evacuation Efficiency of Apartment Evacuation Space Research. p.61-62
  14. National Fire Agency119. (2019). Fire Statistical Yearbook 2019 (Registered No. 11-1661000-000011-10), p.19-41
  15. National Fire Agency119. (2019). Fire Statistical Yearbook 2019(Registered No. 11-1661000-000011-10), p.73-85
  16. National Statistical Office of Korea, 'Breaking 10 Million Houses', A Population and Housing Census', year 2016, p5, p58, table51.
  17. Seoul National University Safety and Disaster Prevention Research Center (2006). Performance-Based Design for Fire Safety, Hammurabi Press. Chapter6. 2-3 Corner Mattress Fire p.113-116
  18. The Busan Ilbo (2015). mobile.busan.com/view.php?code=20150727000075
  19. Yoon, N. (2009). The Asiatoday Newsletter http://asiatoday.co.kr/view.php?key=220422
  20. Yue, L., Kim, S., Kim, K., & Lee, D. (2018). Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit, p.369,370