Acknowledgement
이 연구는 에너지 기술 개발 사업 연구비(과제번호 : 20203030040060) 일부 지원에 의하여 수행되었음을 밝힙니다.
References
- K. W. Rhie et al., "Quatitative Safety Assessment for hydrogen Station Dispenser", Trans. of the Korean Hydrogen and New Energy Society, Vol. 17, No. 3, pp. 272-278, 2006.
- D H. Weo et al., "A Study on FTA of Off-Site Packaged Hydrogen Station", Trans. of Korean Hydrogen and New Energy Society, Vol. 31, No. 1, pp. 73-81, 2020 https://doi.org/10.7316/KHNES.2020.31.1.73
- J. N. Park, "Status of Hydrogen Station Technology and Policy", KIC News, Vol. 21, No. 3, pp. 10-19, 2018.
- K. H. Hwang et al., "Solenoid Valve Response Characteristics of Ultra High Pressure Hydrogen Storage", KIC News, Vol. 19, No. 5, 2019.
- KS B ISO 19880-3, "Gaseous hydrogen -Fueling Stations- Part3:Valves", pp. 7~11, 2019.
- D. S. Kim et al., 2006, "Thermal Stress and Flow Analysis of a Cryogenic Ball Valve," Journal of Drive and Control, Vol. 3, No. 4, pp. 8~13.
- C. K. Kim and J. Y. Yoon, "A Study on Structural analysis of High-Pressure Pipeline Retainer-Type Ball Valve by Pressure Testing of the Industrial Standard", The KSFM Journal of Fluid Machinery, Vol. 18, No. 5, pp. 13~18, 2015. https://doi.org/10.5293/kfma.2015.18.5.013
- H. P. Jeon, D. Y. Kim and J. C. Lee, 2014, "CFD Analysis on the Flow Characteristics with Flow Coefficient in a PFA Lined Ball Valve for Different Opening Degrees," The KSFM Journal of Fluid Machinery, Vol. 17, No. 4, pp. 76~80. https://doi.org/10.5293/kfma.2014.17.4.076
- S. Bagheriard, I. F. Pariente and M. Guagliano, 2013, "Failure analysis of a Large Ball Valve for Pipe-lines," Egineering Failure Analysis, Vol. 32, pp. 167~177. https://doi.org/10.1016/j.engfailanal.2013.03.012
- William F. Riley et al., "Mechanics of Materials", John Wiley & Sons, Inc., Fifth Edition, pp. 244~245.
- M. Endo and Y. Murakami, "Effects of an Artificial Small Defect on Torsional Fatigue Strength of Steel", Trans. ASME, Vol. 109, pp. 124~129, 1987. https://doi.org/10.1115/1.3261303
- L F Acevedo Roman, et al., "Numerical Study of the Stress Concentration Ffactor in Geometries of Machine Elements Using Ansys and Inventor", Journal of Physics, 2020
- E. A. Jeong et al., "A Study on Dehumidification Characteristics of Hollow Fiber Membrane Module for Pneumatic Power Unit Using Fluid-Solid Interaction Analysis", Journal of Drive and Control, Vol.16, No.4, pp.65-73, 2019. https://doi.org/10.7839/KSFC.2019.16.4.065
- K. H. Han et al., "A Study on the Development of Two-Phase Nozzle Suitable for Multi-purpose Spraying in Orchards", Journal of Drive and Control, Vol.17, No.4, pp.1-7, 2020. https://doi.org/10.7839/KSFC.2020.17.4.001
- ANSI/ISA-75.02.01-2008, "Control Valve Capacity Test Procedures", 2009.