Acknowledgement
This research was supported by the National Research Foundation of Korea (NRF) funded by Korean government (Ministry of Science and ICT) (Grant No. 2017M2A8A5014754).
References
- H. Christensen, Remodeling of the oxidant species during radiolysis of high-temperature water in a pressurized water reactor, Nucl. Technol. 109 (1995) 373-382, https://doi.org/10.13182/NT95-A35086.
- B. Pastina, J.A. LaVerne, Effect of molecular hydrogen on hydrogen peroxide in water radiolysis, J. Phys. Chem. 105 (2001) 9316-9322, https://doi.org/10.1021/jp012245j.
- H. Takiguchi, M. Ullberg, S. Uchida, Optimization of dissolved hydrogen concentration for control of primary coolant radiolysis in pressurized water reactors, J. Nucl. Sci. Technol. 41 (2004) 601-609, https://doi.org/10.1080/18811248.2004.9715523.
- J.C. Wren, Steady-state radiolysis: effects of dissolved additives, in: Nucl. Energy Environ., American Chemical Society, 2010, pp. 22-271, https://doi.org/10.1021/bk-2010-1046.ch022.
- Y. Kumagai, A. Kimura, M. Taguchi, R. Nagaishi, I. Yamagishi, T. Kimura, Hydrogen production in gamma radiolysis of the mixture of mordenite and seawater, J. Nucl. Sci. Technol. 50 (2013) 130-138, https://doi.org/10.1080/00223131.2013.757453.
- K. Hata, H. Inoue, T. Kojima, A. Iwase, S. Kasahara, S. Hanawa, F. Ueno, T. Tsukada, Hydrogen peroxide production by gamma radiolysis of sodium chloride solutions containing a small amount of bromide ion, Nucl. Technol. 193 (2016) 434-443, https://doi.org/10.13182/NT15-32.
- A. Rufus, V. Sathyaseelan, M. Srinivasan, P.S. Kumar, S. Veena, S. Velmurugan, S. Narasimhan, Chemistry aspects pertaining to the application of steam generator chemical cleaning formulation based on ethylene diamine tetra acetic acid, Prog. Nucl. Energy 39 (2001) 285-303, https://doi.org/10.1016/S0149-1970(01)00004-X.
- H. Kawamura, K. Fujiwara, H. Kanbe, H. Hirano, H. Takiguchi, K. Yoshino, S. Yamamoto, T. Shibata, K. Ishigure, Applicability of chemical cleaning process to steam generator secondary side, (III), J. Nucl. Sci. Technol. 43 (2006) 655-668, https://doi.org/10.1080/18811248.2006.9711145.
- M. Suzuki, E. Oohashi, Cleaning the secondary side of steam generators of Tomari Power Station Unit 1/2 using ASCA and UEC technology, E-Journal Adv. Maint. 4 (2012) 7. http://inis.iaea.org/search/search.aspx?orig_q=RN:44084602.
- S. Uchida, Y. Katsumura, Water chemistry technology - one of the key technologies for safe and reliable nuclear power plant operation, J. Nucl. Sci. Technol. 50 (2013) 346-362, https://doi.org/10.1080/00223131.2013.773171.
- J.W. Kormuth, The control of cobalt-58 dissolution during refueling shutdowns of pressurized water reactors using a hydrogen peroxide addition, Nucl. Technol. 37 (1978) 99-102, https://doi.org/10.13182/NT78-A31976.
- I. Betova, M. Bojinov, T. Saario, Start-up and shut-down water chemistries in pressurized water reactors, VTT Res. Rep. (2012) 1-81. VTT-R-00699-12, http://www.vtt.fi/inf/julkaisut/muut/2012/VTT-R-00699-12.pdf.
- J.P. Simpson, P.H. Valloton, Experiments on Container Materials for Swiss High-Level Waste Disposal Projects Part II, Nagra NTB, 1984, pp. 1-84.
- W.H. Yunker, R.S. Glass, Long-term corrosion behavior of copper-base materials in a gamma-irradiated environment, MRS Proc. 84 (1986) 579, https://doi.org/10.1557/PROC-84-579.
- F. King, C.D. Litke, The Corrosion of Copper in Synthetic Groundwater at 150 C-Part I. The Results of Short-Term Electrochemical Tests, 1987.
- J. Kass, Evaluation of copper, aluminum bronze, and copper-nickel container material for the Yucca mountain project, Canada. http://inis.iaea.org/search/search.aspx?orig_q=RN:23004457, 1990.
- C. Corbel, V. Wasselin-Trupin, B. Hickel, D. Feron, M. Roy, F. Maurel, Effect of irradiation on long term alteration of oxides and metals in aqueous solutions. https://inis.iaea.org/search/search.aspx?orig_q=RN:35038877, 2003 (accessed April 10, 2020).
- A. Bjorkbacka, S. Hosseinpour, C. Leygraf, M. Jonsson, Radiation induced corrosion of copper in anoxic aqueous solution, Electrochem. Solid State Lett. 15 (2012), https://doi.org/10.1149/2.022205esl.
- A. Bjorkbacka, S. Hosseinpour, M. Johnson, C. Leygraf, M. Jonsson, Radiation induced corrosion of copper for spent nuclear fuel storage, Radiat. Phys. Chem. 92 (2013) 80-86, https://doi.org/10.1016/J.RADPHYSCHEM.2013.06.033.
- G. Sattonnay, C. Ardois, C. Corbel, J.F. Lucchini, M.-F. Barthe, F. Garrido, D. Gosset, Alpha-radiolysis effects on UO2 alteration in water, J. Nucl. Mater. 288 (2001) 11-19, https://doi.org/10.1016/S0022-3115(00)00714-5.
- E. Ekeroth, M. Jonsson, Oxidation of UO2 by radiolytic oxidants, J. Nucl. Mater. 322 (2003) 242-248, https://doi.org/10.1016/J.JNUCMAT.2003.07.001.
- E. Ekeroth, O. Roth, M. Jonsson, The relative impact of radiolysis products in radiation induced oxidative dissolution of UO2, J. Nucl. Mater. 355 (2006) 38-46, https://doi.org/10.1016/J.JNUCMAT.2006.04.001.
- C.R. Raj, T. Okajima, T. Ohsaka, Gold nanoparticle arrays for the voltammetric sensing of dopamine, J. Electroanal. Chem. 543 (2003) 127-133, https://doi.org/10.1016/S0022-0728(02)01481-X.
- A.N. Shipway, E. Katz, I. Willner, Nanoparticle arrays on surfaces for electronic, optical, and sensor applications, ChemPhysChem 1 (2000) 18-52, https://doi.org/10.1002/1439-7641(20000804)1:1<18::AID-CPHC18>3.0.CO;2-L.
- T. Sagara, N. Kato, N. Nakashima, Electroreflectance study of gold nano-particles immobilized on an aminoalkanethiol monolayer coated on a polycrystalline gold electrode surface, J. Phys. Chem. B 106 (2002) 1205-1212, https://doi.org/10.1021/jp011807w.
- J. Wang, Y. Lin, L. Chen, Organic-phase biosensors for monitoring phenol and hydrogen peroxide in pharmaceutical antibacterial products, Analyst 118 (1993) 277-280, https://doi.org/10.1039/AN9931800277.
- M. Shamsipur, M. Asgari, M.G. Maragheh, A.A. Moosavi-Movahedi, A novel impedimetric nanobiosensor for low level determination of hydrogen peroxide based on biocatalysis of catalase, Bioelectrochemistry 83 (2012) 31-37, https://doi.org/10.1016/J.BIOELECHEM.2011.08.003.
- P.D. Sanchez, P.T. Blanco, J.M.F. Alvarez, M.R. Smyth, R. O'Kennedy, Flow-injection analysis of hydrogen peroxide using a horseradish peroxidase-modified electrode detection system, Electroanalysis 2 (1990) 303-308, https://doi.org/10.1002/elan.1140020407.
- U. Wollenberger, J. Wang, M. Ozsoz, E. Gonzalez-Romero, F. Scheller, Bulk modified enzyme electrodes for reagentless detection of peroxides, Bioelectrochem. Bioenerg. 26 (1991) 287-296, https://doi.org/10.1016/0302-4598(91)80030-7.
- A. Morales, F. Cespedes, J. Munoz, E. Martinez-Fabregas, S. Alegret, Hydrogen peroxide amperometric biosensor based on a peroxidase-graphite-epoxy biocomposite, Anal. Chim. Acta 332 (1996) 131-138, https://doi.org/10.1016/0003-2670(96)82793-0.
- Y. Xiao, H.-X.X. Ju, H.-Y.Y. Chen, Hydrogen peroxide sensor based on horseradish peroxidase-labeled Au colloids immobilized on gold electrode surface by cysteamine monolayer, Anal. Chim. Acta 391 (1999) 73-82, https://doi.org/10.1016/S0003-2670(99)00196-8.
- S.-Q. Liu, H.-X. Ju, Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode, Anal. Biochem. 307 (2002) 110-116, https://doi.org/10.1016/S0003-2697(02)00014-3.
- H. Yin, S. Ai, W. Shi, L. Zhu, A novel hydrogen peroxide biosensor based on horseradish peroxidase immobilized on gold nanoparticles-silk fibroin modified glassy carbon electrode and direct electrochemistry of horseradish peroxidase, Sensor. Actuator. B Chem. 137 (2009) 747-753, https://doi.org/10.1016/J.SNB.2008.12.046.
- X. Yi, J. Huang-Xian, C. Hong-Yuan, Direct electrochemistry of horseradish peroxidase immobilized on a colloid/cysteamine-modified gold electrode, Anal. Biochem. 278 (2000) 22-28, https://doi.org/10.1006/ABIO.1999.4360.
- L. Menten, M.I. Michaelis, Die kinetik der invertinwirkung, Biochem. Z. 49 (1913) 5.
- H. Lineweaver, D. Burk, The determination of enzyme dissociation constants, J. Am. Chem. Soc. 56 (1934) 658-666. https://doi.org/10.1021/ja01318a036
- K.R. Brown, D.G. Walter, M.J. Natan, Seeding of colloidal Au nanoparticle solutions. 2. Improved control of particle size and shape, Chem. Mater. 12 (2000) 306-313, https://doi.org/10.1021/cm980065p.
- S. Bharathi, M. Nogami, S. Ikeda, Layer by layer self-assembly of thin films of metal hexacyanoferrate multilayers, Langmuir 17 (2001) 7468-7471, https://doi.org/10.1021/la011053c.
- B. Neiman, E. Grushka, O. Lev, Use of gold nanoparticles to enhance capillary electrophoresis, Anal. Chem. 73 (2001) 5220-5227, https://doi.org/10.1021/ac0104375.
- X. Hua, H.L. Xia, Y.T. Long, Revisiting a classical redox process on a gold electrode by operando ToF-SIMS: where does the gold go? Chem. Sci. 10 (2019) 6215-6219, https://doi.org/10.1039/c9sc00956f.
- J. Zhao, R.W. Henkens, J. Stonehuerner, J.P. O'Daly, A.L. Crumbliss, Direct electron transfer at horseradish peroxidase-colloidal gold modified electrodes, J. Electroanal. Chem. 327 (1992) 109-119, https://doi.org/10.1016/0022-0728(92)80140-Y.
- X. Li, J. Wu, N. Gao, G. Shen, R. Yu, Electrochemical performance of l-cysteine-goldparticle nanocomposite electrode interface as applied to preparation of mediator-free enzymatic biosensors, Sensor. Actuator. B Chem. 117 (2006) 35-42, https://doi.org/10.1016/j.snb.2005.10.044.
- S.H. Jung, J.W. Yeon, K. Song, Effect of pH, temperature, and H2O2 on the electrochemical oxidation behavior of iron in perchlorate solutions, J. Solid State Electrochem. 18 (2014) 333-339, https://doi.org/10.1007/s10008-013-2357-z.
- D.C. Harris, Quantitative Chemical Analysis, seventh ed., W.H. Freeman, New York, 2007.
- J.W. Mandler, A.C. Stalker, S.T. Croney, D.W. Akers, N.K. Bihl, L.S. Loret, T.E. Young, In-plant Source Term Measurements at Prairie Island Nuclear Generating Station, US Nuclear Regulatory Commission, United States, 1985.
- M.G. Garguilo, Nhan Huynh, A. Proctor, A.C. Michael, Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer, Anal. Chem. 65 (1993) 523-528, https://doi.org/10.1021/ac00053a007.
- J. Li, S.N. Tan, H. Ge, Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide, Anal. Chim. Acta 335 (1996) 137-145, https://doi.org/10.1016/S0003-2670(96)00337-6.
- A.L. Lehninger, D.L. Nelson, M.M. Cox, Lehninger Principles of Biochemistry, fourth ed., W. H. Freeman, New York, 2005.
- F. Wu, Z. Hu, J. Xu, Y. Tian, L. Wang, Y. Xian, L. Jin, Immobilization of horseradish peroxidase on self-assembled (3-mercaptopropyl)trimethoxysilane film: characterization, direct electrochemistry, redox thermodynamics and biosensing, Electrochim. Acta 53 (2008) 8238-8244, https://doi.org/10.1016/J.ELECTACTA.2008.06.031.
- R.A. Kamin, G.S. Wilson, Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer, Anal. Chem. 52 (1980) 1198-1205, https://doi.org/10.1021/ac50058a010.
Cited by
- Colorimetric detection of hydrogen peroxide with gadolinium complex of phenylboronic acid functionalized 4,5-diazafluorene vol.522, 2021, https://doi.org/10.1016/j.ica.2021.120386