DOI QR코드

DOI QR Code

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

  • Received : 2019.05.22
  • Accepted : 2019.10.11
  • Published : 2021.02.28

Abstract

Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (Ecorr). The pitting potential (Epit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for Ecorr) and the Student t-test for independent samples (for Epit). Results: The mean Ecorr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with Epit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.

Keywords

References

  1. Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988;14:346-351. https://doi.org/10.1016/S0099-2399(88)80196-1
  2. Gavini G, Santos MD, Caldeira CL, Machado MEL, Freire LG, Iglecias EF, Peters OA, Candeiro GTM. Nickel-titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res 2018;32:e67.
  3. Hilt BR, Cunningham CJ, Shen C, Richards N. Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations. J Endod 2000;26:76-80. https://doi.org/10.1097/00004770-200002000-00004
  4. Darabara M, Bourithis L, Zinelis S, Papadimitriou GD. Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions. Int Endod J 2004;37:705-710. https://doi.org/10.1111/j.1365-2591.2004.00866.x
  5. Talha M, Behera CK, Sinha OP. A review on nickel-free nitrogen containing austenitic stainless steels for biomedical applications. Mater Sci Eng C 2013;33:3563-3575. https://doi.org/10.1016/j.msec.2013.06.002
  6. Wright PP, Kahler B, Walsh LJ. Alkaline sodium hypochlorite irrigant and its chemical interactions. Materials (Basel) 2017;10:1147-1155. https://doi.org/10.3390/ma10101147
  7. Pedulla E, Benites A, La Rosa GM, Plotino G, Grande NM, Rapisarda E, Generali L. Cyclic fatigue resistance of heat-treated nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization. J Endod 2018;44:648-653. https://doi.org/10.1016/j.joen.2017.12.011
  8. Ametrano G, D'Anto V, Di Caprio MP, Simeone M, Rengo S, Spagnuolo G. Effects of sodium hypochlorite and ethylenediaminetetraacetic acid on rotary nickel-titanium instruments evaluated using atomic force microscopy. Int Endod J 2011;44:203-209. https://doi.org/10.1111/j.1365-2591.2010.01799.x
  9. Bonaccorso A, Tripi TR, Rondelli G, Condorelli GG, Cantatore G, Schafer E. Pitting corrosion resistance of nickel-titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions. J Endod 2008;34:208-211. https://doi.org/10.1016/j.joen.2007.11.012
  10. Lee JB, Yoon SI. Effect of nitrogen alloying on the semiconducting properties of passive films and metastable pitting susceptibility of 316L and 316LN stainless steels. Mater Chem Phys 2010;122:194-199. https://doi.org/10.1016/j.matchemphys.2010.02.033
  11. Prymak O, Klocke A, Kahl-Nieke B, Epple M. Fatigue of orthodontic nickel-titanium (NiTi) wires in different fluids under constant mechanical stress. Mater Sci Eng A 2004;378:110-114. https://doi.org/10.1016/j.msea.2003.10.332
  12. Stokes OW, Fiore PM, Barss JT, Koerber A, Gilbert JL, Lautenschlager EP. Corrosion in stainless-steel and nickel-titanium files. J Endod 1999;25:17-20. https://doi.org/10.1016/S0099-2399(99)80392-6
  13. Yum JW, Park JK, Hur B, Kim HC. Comparative analysis of various corrosive environmental conditions for NiTi rotary files. J Korean Acad Conserv Dent 2008;33:377-388. https://doi.org/10.5395/JKACD.2008.33.4.377
  14. Berutti E, Angelini E, Rigolone M, Migliaretti G, Pasqualini D. Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. Int Endod J 2006;39:693-699. https://doi.org/10.1111/j.1365-2591.2006.01134.x
  15. Pereira ES, Peixoto IF, Viana AC, Oliveira II, Gonzalez BM, Buono VT, Bahia MG. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments. Int Endod J 2012;45:469-474. https://doi.org/10.1111/j.1365-2591.2011.01998.x
  16. Ye J, Gao Y. Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue. J Endod 2012;38:105-107. https://doi.org/10.1016/j.joen.2011.09.028
  17. Aoun CM, Nehme WB, Naaman AS, Khalil IT. Review and classification of heat treatment procedures and their impact on mechanical behavior of endodontic files. Int J Curr Res 2017;9:51300-51306.
  18. Gutmann JL, Gao Y. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review. Int Endod J 2012;45:113-128. https://doi.org/10.1111/j.1365-2591.2011.01957.x
  19. Prasad PS, Sam JE, Kumar A, Kannan . The effect of 5% sodium hypochlorite, 17% EDTA and triphala on two different rotary Ni-Ti instruments: an AFM and EDS analysis. J Conserv Dent 2014;17:462-466. https://doi.org/10.4103/0972-0707.139842
  20. Ramires I, Guastaldi AC. Study of Ti-6Al-4V biomaterial using electrochemistry and XPS techniques. Quim Nova 2002;25:10-14. https://doi.org/10.1590/S0100-40422002000100003
  21. Olmedo DG, Tasat DR, Duffo G, Guglielmotti MB, Cabrini RL. The issue of corrosion in dental implants: a review. Acta Odontol Latinoam 2009;22:3-9.
  22. Silva EF, Oliveira LF. Chemical and metallographic characterization of stainless steel in implants removed from patients. Acta Ortop Bras 2011;19:280-285. https://doi.org/10.1590/S1413-78522011000500003
  23. Sonntag RE, Gordon JV. Introduction to thermodynamics: classical and statistical. 3rd ed. Hoboken, NJ: John Wiley & Sons, Inc; 1991. p800. 
  24. Lambert FL. Configurational entropy revisited. J Chem Educ 2007;84:1548-1550. https://doi.org/10.1021/ed084p1548
  25. Es-Souni M, Es-Souni M, Fischer-Brandies H. On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility. Biomaterials 2002;23:2887-2894. https://doi.org/10.1016/S0142-9612(01)00416-1
  26. Thompson SA. An overview of nickel-titanium alloys used in dentistry. Int Endod J 2000;33:297-310. https://doi.org/10.1046/j.1365-2591.2000.00339.x