과제정보
이 연구는 서울과학기술대학교 교내연구비의 지원으로 수행되었습니다.
참고문헌
- J. Wang, "Glucose biosensors: 40 years of advances and challenges", Electroanalysis, Vol. 13, No. 12, pp. 983-988, 2001. https://doi.org/10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-#
- K. Tonyushkina and J. H. Nichols, "Glucose meters: a review of technical challenges to obtaining accurate results", J. Diabetes. Sci. Technol., Vol. 3, No. 4, pp. 971-980, 2009. https://doi.org/10.1177/193229680900300446
- K. Hiraka, W. Tsugawa, and R. Asano, M.A. Yokus, K. Ikebukuro, M.A. Daniele, K. Sode, "Rational design of direct electron transfer type l-lactate dehydrogenase for the development of multiplexed biosensor", Biosens. Bioelectron., Vol. 176, p. 112933, 2021. https://doi.org/10.1016/j.bios.2020.112933
- M. B. Gholivand and M. Khodadadian, "Amperometric cholesterol biosensor based on the direct electrochemistry of cholesterol oxidase and catalase on a graphene/ionic liquid-modified glassy carbon electrode", Biosens. Bioelectron., Vol. 53, pp. 472-478, 2014. https://doi.org/10.1016/j.bios.2013.09.074
- M. Das and P. Goswami, "Direct electrochemistry of alcohol oxidase using multiwalled carbon nanotube as electroactive matrix for biosensor application", Bioelectrochemistry, Vol. 89, pp. 19-25, 2013. https://doi.org/10.1016/j.bioelechem.2012.08.007
- S. W. Lee, K. Y. Lee, Y. W. Song, W. K. Choi, J. Chang, and H. Yi, "Direct electron transfer of enzymes in a biologically assembled conductive nanomesh enzyme platform", Adv. Mater., Vol. 28, No. 8, pp. 1577-1584, 2016. https://doi.org/10.1002/adma.201503930
- X. Yu, Y. Gong, W. Xiong, M. Li, J. Zhao, and Y. Che, "Turn-on fluorescent detection of hydrogen peroxide and triacetone triperoxide via enhancing interfacial interactions of a blended system", Anal. Chem., Vol. 91, No. 11, pp. 6967-6970, 2019. https://doi.org/10.1021/acs.analchem.9b01255
- M. P. Wymann, V. von Tscharner, D. A. Deranleau, and M. Baggiolini, "Chemiluminescence detection of H2O2 produced by human-neutrophils during the respiratory burst", Anal. Biochem., Vol. 165, No. 2, pp. 371-378, 1987. https://doi.org/10.1016/0003-2697(87)90284-3
- C. C. Hsu, Y. R. Lo, Y. C. Lin, Y. C. Shi, and P. L. Li, "A Spectrometric method for hydrogen peroxide concentration measurement with a reusable and cost-efficient sensor", Sens., Vol. 15, No. 10, pp. 25716-25729, 2015. https://doi.org/10.3390/s151025716
- Y. Y. Niu, J. Liu, W. Chen, C. X. Yin, W. J. Weng, X. Y. Li, X. L. Wang, G. J. Li, and W. Sun, "A direct electron transfer biosensor based on a horseradish peroxidase and gold nanotriangle modified electrode and electrocatalysis", Anal. Methods, Vol. 10, No. 44, pp. 5297-5304, 2018. https://doi.org/10.1039/c8ay01980k
- I. S. Kucherenko, O. O. Soldatkin, D. Y. Kucherenko, O. V. Soldatkina, and S. V. Dzyadevych, "Advances in nanomaterial application in enzyme-based electrochemical biosensors: a review", Nanoscale Adv, Vol. 1, No. 12, pp. 4560-4577, 2019. https://doi.org/10.1039/C9NA00491B
- S. W. Lee, T. H. Kang, S. K. Lee, K. Y. Lee, and H. Yi, "Hydrodynamic layer-by-layer assembly of transferable enzymatic conductive nanonetworks for enzyme-stickerbased contact printing of electrochemical biosensors", ACS Appl. Mater. Interfaces, Vol. 10, No. 42, pp. 36267-36274, 2018. https://doi.org/10.1021/acsami.8b13070
- P. May, S. Laghmari, and M. Ulbricht, "Concentration polarization enabled reactive coating of nanofiltration membranes with zwitterionic hydrogel", Membranes., Vol. 11, No. 3, pp. 187 2021. https://doi.org/10.3390/membranes11030187
- E. M. Perez and N. Martin, "π - π interactions in carbon nanostructures", Chem. Soc. Rev., Vol. 44, No. 18, pp. 6425-6433, 2015. https://doi.org/10.1039/C5CS00578G
- D. Fass and C. Thorpe, "Chemistry and enzymology of disulfide cross-linking in proteins", Chem. Rev., Vol. 118, No. 3, pp. 1169-1198, 2018. https://doi.org/10.1021/acs.chemrev.7b00123
- T. Pajkossy and S. Vesztergom, "Analysis of voltammograms of quasi-reversible redox systems: Transformation to potential program invariant form", Electrochim. Acta., Vol. 297, pp. 1121-1129, 2019. https://doi.org/10.1016/j.electacta.2018.12.023
- J. L. Tang, J. G. Jiang, Y. H. Song, Z. Q. Peng, Z. Y. Wu, S. J. Dong, and E. K. Wang, "Conformation change of horseradish peroxidase in lipid membrane", Chem. Phys. Lipids., Vol. 120, No. 1-2, pp. 119-129, 2002. https://doi.org/10.1016/S0009-3084(02)00109-3
- Z. P. Kang, K. L. Jiao, C. Yu, J. Dong, R. Y. Peng, Z. Q. Hu, and S. Q. Jiao, "Direct electrochemistry and bioelectrocatalysis of glucose oxidase in CS/CNC film and its application in glucose biosensing and biofuel cells", RSC Adv., Vol. 7, No. 8, pp. 4572-4579, 2017. https://doi.org/10.1039/C6RA26636C