Acknowledgement
이 연구는 2021년도 국토교통과학기술진흥원(21RERP-B082884-8)의 연구비 지원에 의한 결과의 일부임.
References
- ACI Committee 318 (2019). Building code requirements for structural concrete (ACI 318-19), Farmington Hills, MI ; American Concrete Institute (ACI).
- ACI Innovation Task Group 5 (2007). Acceptance criteria for special unbonded post-tensioned precast structural walls based on validation testing (ACI ITG-5.1-07) and commentary. American Concrete Institute, USA.
- Brunesi, E., & Nascimbene, R. (2017). Experimental and numerical investigation of the seismic response of precast wall connections, Bulletin of Earthquake Engineering, 15(12), 5511-5550. https://doi.org/10.1007/s10518-017-0166-y
- Choi, H. K., Choi, Y. C., & Choi, C. S. (2010). Hysteretic behavior and seismic resistant capacity of precast concrete beam-to-column connections, Journal of the Earthquake Engineering Society of Korea, 14(4), 61-71. https://doi.org/10.5000/EESK.2010.14.4.061
- Guo, W., Zhai, Z., Yu, Z., Chen, F., Gong, Y., & Tan, T. (2019). Experimental and numerical analysis of the bolt connections in a low-rise precast wall panel structure system, Advances in Civil Engineering, ID 7594132, 1-22.
- Hawkins, N., & Ghosh, S. (2004). Requirements for the use of PRESSS moment-resisting frame systems, PCI Journal, 49, 98-103. https://doi.org/10.15554/pcij.03012004.98.103
- Jiang, S., Lian, S., Zhao, J., Li, X., & Ma, S. (2018). Influence of a new norm of bolted connection on the mechanical behaviors of a PC shear wall, Applied Sciences, MDPI, 8(8), 1-19.
- Kim, S. K., Seo, S. Y., Kim, S. H., Lim, B. H., & Cha, J. W. (2019). Hysteretic characteristic of precast concrete wall with box type connector for vertical bars under horizontal load, Journal of the Korea Concrete Institute, 31(2), 153-163. https://doi.org/10.4334/jkci.2019.31.2.153
- Lee, J. Y., & Seo, S. Y. (2020). Seismic design of PC structures, Review of Architecture and Building Science, 64(7), 11-15.
- Lee, S. S., & Park, K. S. (2018). A experimental study on structural behavior of hybrid precast concrete panel, Journal of the Architectural Institute of Korea Structure and Construction Section, 34(9), 11-18.
- Lim, W. Y., & Hong, S. G. (2014). Behavior of precast concrete shear walls with c-type connections, Journal of the Korea Concrete Institute, 22(4), 461-472. https://doi.org/10.4334/JKCI.2010.22.4.461
- NEHRP (1994). Recommended provisions for seismic regulations of new buildings: Part 1, provisions. FEMA 222A, National Earthquake Hazard Reduction Program, Federal Emergency Management Agency, USA.
- Seo, S. Y., Kim, S. H., Cha, J. W., & Lim, B. H. (2020). Seismic capacity of precast concrete wall corresponding to connection detail of vertical bars at horizontal joint, Journal of the Korea Concrete Institute, 32(6), 541-551. https://doi.org/10.4334/JKCI.2020.32.6.541
- Sun, J., Qiu, H., & Jiang, H. (2018). Experimental study and associated mechanism analysis of horizontal bolted connections involved in a precast concrete shear wall system, Structural Concrete, International Federation for Structural Concrete(fib), 20, 282-295.
- Xu, G., Wang, Z., Wu, B., Bursi. O. S., Tan, X., Yang, Q., & Wen, L. (2017). Seismic performance of precast shear wall with sleeves connection based on experimental and numerical studies, Engineering Structures, Elsevier, 150, 346-358. https://doi.org/10.1016/j.engstruct.2017.06.026