DOI QR코드

DOI QR Code

A Study on the Odor Removal Control System of Sewage Sludge

  • KIM, Su-Hye (Department of Environmental health and Safety, Eulji University) ;
  • LEE, So-Hee (Department of Environmental health and Safety, Eulji University) ;
  • YUN, Yeo-Jin (Department of Environmental health and Safety, Eulji University) ;
  • CHOI, Soo-Young (Department of Environmental health and Safety, Eulji University) ;
  • JUNG, Min-Jae (Department of Environmental health and Safety, Eulji University) ;
  • KWON, Woo-Taeg (Department of Environmental health and Safety, Eulji University)
  • 투고 : 2021.06.21
  • 심사 : 2021.06.30
  • 발행 : 2021.06.30

초록

Purpose: The purpose of this study is to reduce odor complaints by identifying problems with odor management at the site of the water regeneration center and researching odor management methods. Due to the high population density of Korea, sewage treatment facilities are adjacent to residential and industrial areas. According to previous studies, the main malodor-emitting facilities of sewage treatment facilities were preliminary treatment facilities (2,220 times), sedimentation basins (4,628 times), and sludge treatment facilities (9,616 times). Research design, data and methodology: Compound malodors and designated malodor-producing substances were collected from five site boundaries of the water regeneration center and analyzed according to the official methods to test malodor, and a total of two times (August and September 2020) were conducted. Results: As a result of the measurement, in the green area in front of the center office, compound malodors were detected at a maximum of 8 times and at least 3 times during the dawn time. As for the designated malodor-producing substances, 0.1ppm of ammonia was detected in the green area in front of the center office and the park golf course. This is within 15 times the maximum allowable emission level of compound malodors and within 1ppm of the maximum allowable emission level of ammonia. Conclusions: Even if the dilution rate of the compound malodors did not exceed the maximum allowable emission level, the odor could be recognized, and more research is needed in the future to establish effective reduction measures according to the subjective and individual and seasonal odor characteristics.

키워드

참고문헌

  1. Do, W. G., & Jung, W. S. (2020). Contribution Analysis by Malodor Substances from Compound malodor Emission Sources in Urban Industrial Area. Journal of Korean Society for Atmospheric Environment, 36(3), 360-374. https://doi.org/10.5572/KOSAE.2020.36.3.360
  2. Hong, O. F., Kabir, E., Susaya, J., & Kim, K. H. (2010). Characteristics of major offensive odorants emitted from urban stormwater catch basins. Analytical Science & Technology, 23(4), 347-356. doi: 10.5806/AST.2010.23.4.347
  3. Ji, H. W., & Yoo, S. S. (2018). The measures to reduce sewer odor in South Korea through sewer odor reduction system in Los Angeles and San Francisco. Journal of Korean Society of Water and Wastewater, 32(5), 445-451. https://doi.org/10.11001/jksww.2018.32.5.445
  4. Jung, J. S., Kim, D. C., Lee, H. C., Yeon, S. W., & Yeon I. J. (2016). A Study on the Odor Compounds Emitted using Odor Contribution Analysis - Focus on the Ochang Scientific Industrial Complex Area -. Journal of Environmental Science International, 25(9), 1329-1339. doi:10.5322/JESI.2016.25.9.1329
  5. Kim, B. U., Hyun, G. W., Bae, S. H., Hong, Y. K., Lee, Y. S., Yi, G. H., Huh, I. R., & Choi, S. B. (2020). A Study on the Characteristics and Distribution of the Time-Spatial Occurrence of Offensive Odors -Gangwon Province-. J Environ Health Sci, 46(4), 376-387. doi:10.5668/JEHS.2020.46.4.376
  6. Kim, H. J., & Dong, J. I. (2020). Evaluation and Emission Characterization of the Malodorous Substances Produced by Direct Drying of Sewage Sludge. J. Korea Soc. Waste Manag., 37(6), 435-442. https://doi.org/10.9786/kswm.2020.37.6.435
  7. Kim, J. W., & Kim, H. O. (2007). Quantification of Odors on the Boundary of Water Reclamation Centers in Seoul. Korean Society of Environmental Engineers, 29(7), 747-754.
  8. Ko, B. C., Lee, J. K., Lee, Y. S., Lee, M. G., & Kam, S. K. (2012). A Study on Odor Emission Characteristics of Domestic Sewage Treatment Facilities Using Composite Odor Concentration and Hydrogen Sulfide Concentration. Journal of the Environmental Sciences, 21(11), 1379-1388. doi:10.5322/JES.2012.21.11.1379
  9. Lee, C. H., Jeon, H. S., Kwon, B. Y., Kim, E. D., Jang, Y. J., Lee, M. S., Keum, J. L., & Lee, C. H., Jeon, H. S., Shin, M. C., Kim, E. D., Jang, Y. J., Kwon, B. Y., & Song, H. B. (2016). Emission Characteristics of Odor Compounds from Fundamental Environmental Facilities in an Industrial Complex Area in Daegu City, J Environ Health Sci, 42(4), 246-254. doi:10.5668/JEHS.2016.42.4.246
  10. Lee, M. S., Keum, J. L., Kang, D. H., Jo, H. W., Kwon, B. Y., Kim, E. D., Lee, C. H., Song, H. B., & Shin, S. H. (2021). Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-Gu, Daegu City. J Environ Health Sci, 47(1), 45-54. https://doi.org/10.5668/JEHS.2021.47.1.45
  11. Ministry of Environment(MOE). (2007). Odor control manual
  12. Ministry of Environment(MOE). (2019a). Malodor prevention Act.
  13. Ministry of Environment(MOE). (2019b). Official Methods to Test
  14. Malodor of Ammonia. Ministry of Environment(MOE). (2019c). Official Methods to Test
  15. Malodor of Surfur compounds. Moon, N. K., Lee, Y. S., Kang, Y. H., & Kim, Y. H. (2005). The Application of Air Quality Models on Environment Impact Assessment. Seoul, Korea: Korea Environment Institute.
  16. Paeng, J. I., Cho, S. J., & Kim, H. M. (2005). Evaluation of Odor Character at Wastewater Treatment Plant by Olfactory Method. Korea Society of Environment Administration, 11(2), 73-79.
  17. Park, C. J., & Yoo, J. Y. (2020). On the method of odor management with the civil complaint patterns for the improvement of urban environment. J. Odor Indoor Environ., 19(2), 120-127. doi: 10.15250/joie.2020.19.2.120
  18. Seo, B. R., Jeon, H. S., Park, Y. S., Yun, B. R., Jang, T. H., & Kim, T. O. (2013). The Emission Characteristics and Management of Odor Compounds from Public Sewage Treatment Facility. Journal of Korean Society of Odor Research and Engineering, 12(3), 97-109. https://doi.org/10.11161/jkosore.2013.12.3.97
  19. Song, H. B. (2017). Emission Characteristics of Odor Compounds from a Dyeing Wastewater Treatment Plant in an Industrial Complex Area in Daegu City. J Environ Health Sci, 43(4), 314- 323. doi: 10.5668/JEHS.2017.43.4.314