References
- S. J. Han, Trends of Healthcare Industry, 2019, from http://www.bioin.or.kr/board.do?num=291513&cmd=view&bid=industry
- Global Healthcare Market Report, 2019, from https://www.nipa.kr/main/selectBbsNttView.do?key=307&bbsNo=40&nttNo=6862
- Tadano, S., Takeda, R., and Miyagawa, H. , "Three Dimensional Gait Analys is using Wearable Acceleration and Gyro Sensors based on Quaternion Calcul ations," Sensors, Vol. 13, No. 7, pp. 9321-9343, 2013. https://doi.org/10.3390/s130709321
- Y. K. Kim, S. M. Kim, H. S Lho, and W. D. Cho, "Real-Time Step Count Detection Algorithm Using a Tri-Axial Accelerometer," Journal of Internet Computing and Services, Vol. 12, No. 3, pp. 17-26, 2011.
- G. S. Heo, S. H. Yang, S. R. Lee, J. G. Lee, and C. Y. Lee. "A Study on Particular Abnormal Gait Using Accelerometer and Gyro Sensor," Journal of the Korean Society of Precision Engineering, Vol. 29, No. 11, pp. 1199-1206, 2012. https://doi.org/10.7736/KSPE.2012.29.11.1199
- D. Y. Choi, and K. H. Kim, "A Study of Human Gait Discrimination Using Multi-Pressure Sensor," The Transactions of The Korean Institute of Electrical Engineers, Vol. 65, No. 4, pp. 673-77, 2016. https://doi.org/10.5370/KIEE.2016.65.4.673
- E. S. Kim, "Fabrication of shoes for analyzing human gait pattern using strain sensors," The Journal of the Korea Institute of Electronic Communication Sciences, Vol. 8, No.9, pp. 1407 - 1412, 2013. https://doi.org/10.13067/JKIECS.2013.8.9.1407
- J. Park et al., "Foot plantar pressure measurement system using highly sensitive crack-based sensor," Sensors, Vol. 19, No. 24, pp. 5504, 2019. https://doi.org/10.3390/s19245504
- Paredes-Madrid, Leonel., Palacio, C., Matute, A., Parra Vargas, C., "Underlying Physics of Conductive Polymer Composites and Force Sensing Resistors (FSRs) under Static Loading Conditions," Sensors, Vol. 17, No. 9, pp. 2108, 2017. https://doi.org/10.3390/s17092108
- FLX-Datasheet-A201-RevH, form https://www.tekscan.com/products-solutions/force-se nsors/a201
- Parmar, S., Khodasevych, I., and Troynikov, O., "Evaluation of Flexible Force Sensors for Pressure Monitoring in Treatment of Chronic Venous Disorders," Sensors, Vol. 17, No. 8, pp. 1923, 2017.
- Khodasevych, I., Parmar, S., and Troynikov, O., "Flexible Sensors for Pressure Therapy: Effect of Substrate Curvature and Stiffness on Sensor Performance," Sensors, Vol. 17, No. 10, pp. 2399, 2017. https://doi.org/10.3390/s17102399
- FlexiForce Sensors User Manual, form https://biomedical.com/media/support/a2011.pdf
- The Wrong Step, like Out-Toeing Gait, 2018, form https://m.post.naver.com/viewer/postView.nhn?volumeNo=16682538&memberNo=15460571
- W. Kim, W. Shin, H. Kim, and H. Yeom, "Development of Gait Correction System for Real-Time Gait," International journal of advanced smart convergence, Vol. 9, No. 4, pp. 139-148, 2020. https://doi.org/10.7236/IJASC.2020.9.4.139