과제정보
본 연구는 국토교통부 국토교통기술촉진연구사업(과제번호: N20CTAP-C157477-01)에 의한 연구 결과이며 이에 감사드립니다.
참고문헌
- ACI Committee 355.2. (2011), Evaluating the Performance of Post-Installed Mechanical Anchors in Concrete.
- ACI Committee 318. (2011), Building Code Requirements For Structural Concrete and Commentary.
- ETAG, (2003), GUIDELINE FOR EUROPEAN TECHNICAL APPROVAL OF METAL ANCHORS FOR USEIN CONCRETE.
- Korean Building and Commentary, (2016), Architectural Institute of Korea.
- Hilti, (2019), Anchor Fastening Technical Guide Edition 19, https: //www.hilti.com/medias/sys_master/documents/hd8/h29/9484912361502/Technical-information-ASSET-DOC-LOC-1543421.
- HILTI, (2016), Hilti Technical Report.
- J. Lubliner, J. Oliver, S. Oller, E. Onate, (1989), A Plastic-damage Model for Concrete, International Journal of Solids and Structures, 25(3), 299-326. https://doi.org/10.1016/0020-7683(89)90050-4
- Bang. J. S., Youn. I. R., Kwon. Y. S., and Yim. H. J. (2020), Nonlinear Tensile Behavior Analysis of Torque-controlled Expansion Anchors Using Finite Element Analysis, Journal of the Korea Institute for Structural Maintenance and Inspection, 24(4), 91-99. https://doi.org/10.11112/JKSMI.2020.24.4.91
- Delhomme, F., Pallud, B., and Rouane, N. (2018), Tightening Torque Influence on Pullout Behavior of Post-installed Expansion Anchors, KSCE Journal of Civil Engineering, 22(10), 3931-3939. https://doi.org/10.1007/s12205-018-0930-9
- Chen, Z., Nassiri, S., Lamanna, A., and Cofer, W. (2020), Investigation of Pull-Through and Pullout Failure Modes of Torque-Controlled Expansion Anchors. ACI Structural Journal, 117(1).
- Gontarz, J., and Podgorski, J. (2019), Analysis of Crack Propagation in a "Pull-out" Test, Studia Geotechnica et Mechanica.
- Tsavdaridis, K. D., Shaheen, M. A., Baniotopoulos, C., and Salem, E. (2016), Analytical Approach of Anchor Rod Stiffness and Steel Base Plate Calculation Under Tension. In Structures, 5, 207-218. https://doi.org/10.1016/j.istruc.2015.11.001
- Mahrenholtz, P., and Eligehausen, R. (2015), Post-installed Concrete Anchors in Nuclear Power Plants: Performance and Qualification, Nuclear Engineering and Design, 287, 48-56. https://doi.org/10.1016/j.nucengdes.2015.03.004
- Karmazinova, M., Melcher, J., and Kala, Z. (2009), Design of Expansion Anchors to Concrete Based on Results of Experimental Verification, Advanced Steel Construction, 5(4), 390-405.
- Kim, J. S., Jung, W. Y., Kwon, M. H., and Ju, B. S. (2013), Performance Evaluation of the Post-installed Anchor for Sign Structure in South Korea, Construction and Building Materials, 44, 496-506. https://doi.org/10.1016/j.conbuildmat.2013.03.015
- KCI, (2018), Anchor Design Method and Sample for Concrete.
- Hur. M. W., Chae. K. H., An. Y. S., and Park. T. W., (2019), An Performance Evaluation of Post-installed Anchor according to the Effective Embedment Length, Journal of the Korean Institute of Educational Facilities, 131(7), 19-25.