과제정보
This work was supported by Dongseo University, "Dongseo Cluster Project" Research Fund of 2021 (DSU-20210004)
참고문헌
- The Korean Society of Medical Imaging Technology. Textbook of radiographic positioning and clinical diagnosis. Seoul: Chung-Ku Publisher; 2019.
- Kim KP. Assessment of radiation exposure of Korean popoulation by medical radiation. Research Report No. 11-1790387-000030-01. Osong: Korea Centers for Disease Control and Prevention; 2020.
- Zetterberg LG, Espeland A. Lumbar spine radiography - poor collimation practices after implementation of digital technology. The British Journal of Radiology. 2011;84:566-9. https://doi.org/10.1259/bjr/74571469
- Do KH. Development of the diagnostic reference level of general radiograpy: Twelve area including Brain, chest, pelvis, etc. Research Report No. 11-1352159-000916-01. Osong: Korea Centers for Disease Control and Prevention; 2017.
- Zhuo SH, McCarthy ID, McGregor AH, Coombs RRH, Hughes SPF. Geometrical dimensions of the lower lumbar vertebrae - analysis of data from digitised CT images. European Spine Journal. 2000;9:242-8. https://doi.org/10.1007/s005860000140
- Kenichi K. Efforts to protect radiation and reduce radiation exposure in FPD systems. Innervision. 2012;27:14-8.
- IEC 62494-1. Ed 1.0. Medical electrical equipment - Exposure index of digital X-ray imaging system-Part 1: Definitions and requirements for general radiography. Geneva: International Electrotechnical Commission; 2008.
- Park HM, Yoon YS, Roh YH, Kim SJ, Na CY, Han TH, et al. Evaluation of image receptor characteristics in computed radiography system using exposure index in international electrotechnical commission (I). Journal of Radiological Science and Technology. 2019;42(4):291-9. https://doi.org/10.17946/JRST.2019.42.4.291
- Park HM, Yoon YS, Kim JM, Kim JS, Jeong HW, Tanaka N, et al. Use of clinical exposure index and deviation index based on national diagnostic reference level as dose-optimization tools for general radiography in Korea. Radiation Protection Dosimetry. 2020;191(4):439-51. https://doi.org/10.1093/rpd/ncaa185
- Jeong HW, Min JW. A study on quality control for medical image by using deviation index of digital radiology. Journal of Radiological Science and Technology. 2018;41(6):533-8. https://doi.org/10.17946/JRST.2018.41.6.533
- Park HM, Yoon YS, Tanaka N, Kim JS, Kim JM, Morishita J. Feasibility of displayed exposure index in IEC standard framework as a dose optimisation tool for digital radiography systems. Radiation Protection Dosimetry. 2020;189(3):384-94. https://doi.org/10.1093/rpd/ncaa052
- Jeong HW, Min JW. A case study of application of exposure index in computed radiography by using human chest phantom. Journal of Radiological Science and Technology. 2020;43(2):115-21. https://doi.org/10.17946/JRST.2020.43.2.115
- Zhang M, Chu C. Optimization of the radiological protection of patients undergoing digital radiography. Journal of Digital Imaging. 2012;25:196-200. https://doi.org/10.1007/s10278-011-9395-9
- Kim JK, Kim JK. Evaluation on organ dose and image quality of lumbar spine radiography using glass dosimeter. Journal of Radiological Science and Technology. 2016;39(1):1-11. https://doi.org/10.17946/JRST.2016.39.1.01
- Yoon YS, Park HM, Kim JM, Kim JS, Roh YH, Tanaka N, et al. Proper management of the clinical exposure index based on body thickness using dose optimization tools in digital chest radiography: A phantom stduy. International Journal of Environmental Research and Public Health. 2021;18(10):5203. https://doi.org/10.3390/ijerph18105203