Acknowledgement
The authors gratefully acknowledge the financial support provided by the National Nature Science Foundations of China (51978081), Horizon 2020- Marie Sklodowska-Curie Individual Fellowship of European Commission (REUSE: 793787).
References
- Abaqus/Explicit user's manual, version (2018), Pawtucket: Hibbit, Karlsson & Sorensen, Inc.; 2018.
- Ataei, A., Bradford, M.A. and Liu, X. (2016), "Experimental study of composite beams having a precast geopolymer concrete slab and deconstructable bolted shear connectors", Eng. Struct., 114, 1-13. https://doi.org/10.1016/j.engstruct.2015.10.041.
- Ban, H., Uy, B., Pathirana, S.W., Henderson, I., Mirza, O. and Zhu, X. (2015), "Time-dependent behaviour of composite beams with blind bolts under sustained loads", J. Constr. Steel Res., 112, 196-207. https://doi.org/10.1016/j.jcsr.2015.05.004
- Birtel, V. and Mark, P. (2006), Parameterised finite element modelling of RC beam shear failure. The 19th Annual International ABAQUS Users' Conference, ABAQUS Inc, Boston, USA, 95-108.
- Brambilla, G., Lavagna, M., Vasdravellis, G. and Castiglioni, C. A. (2019), "Environmental benefits arising from demountable steel-concrete composite floor systems in buildings", Resources, Conservation and Recycling, 141(October 2018), 133-142. https://doi.org/10.1016/j.resconrec.2018.10.014.
- BSI (British Standards Institution). (2002), Eurocode 2. Design of concrete structures. Part 1-1. General rules and rules for buildings. EN 1992-1-1. Brussels, Belgium: BSI.
- Couchman, G. (2014), Design of composite beams using precast concrete slabs in accordance with Eurocode 4: Steel construction institute publication P401. Ascot, UK: Berkshire
- Dai, X.H., Lam, D. and Saveri, E. (2015), "Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors", J. Struct. Eng., 04015025. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001267.
- Densley Tingley, D. and Davison, B. (2011), "Design for deconstruction and material reuse", Proc. Inst. Civ. Eng. Energy, 164(4), 195-204. https://doi.org/10.1680/ener.2011.164.4.195.
- EN 1994-1-1 (2004), Eurocode 4: Design of composite steel and concrete structures. Part 1-1: General rules and rules for buildings, European Committee for Standardization (CEN), Brussels.
- Feidaki, E., Vasdravellis, G., He, J. and Wang, S. (2019), "Steel-Yielding Demountable Shear Connector for Composite Floors with Precast Hollow-Core Slab Units", J. Struct. Eng., 145(8), 1-17. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002356.
- FIB, Model Code (2010), Final Draft, vol. 1, 2010 (Lausanne).
- He, J., Lin, Z., Liu, Y., Xu, X., Xin, H. and Wang, S. (2020), "Shear stiffness of headed studs on structural behaviors of steel-concrete composite girders", Steel Compos. Struct., 36(5), 553-568. https://doi.org/10.12989/scs.2020.36.5.553.
- Henderson, I.E.J., Zhu, X.Q., Uy, B. and Mirza, O. (2015), "Dynamic behaviour of steel-concrete composite beams with different types of shear connectors. Part I: Experimental study", Eng. Struct., 103, 298-307. https://doi.org/10.1016/j.engstruct.2015.08.035.
- Hordijk, D.A. (1992), "Tensile and tensile fatigue behaviour of concrete; experiments, modelling and analyses", Heron, 37, 3-79.
- IEA (International Energy Association). (2007), Tracking industrial energy efficiency and CO2 emissions. Paris: IEA
- Kozma, A., Odenbreit, C., Braun, M.V., Veljkovic, M. and Nijgh, M.P. (2019), "Push-out tests on demountable shear connectors of steel-concrete composite structures", Structures, 21, 45-54. https://doi.org/10.1016/j.istruc.2019.05.011.
- Lam, D., Elliott, K.S. and Nethercot, D.A. (2000a), "Experiments on composite steel beams with precast concrete hollow core floor slabs", Proceedings of the Institution of Civil Engineers, Structures and Buildings, 140, 127-138. https://doi.org/10.1680/stbu.2000.140.2.127.
- Lam, D., Elliott, K.S. and Nethercot, D.A. (2000b), "Design procedures for composite steel beams with precast concrete hollow core floor slabs", Proceedings of the Institution of Civil Engineers, Structures and Buildings, 140(5), 139-149. https://doi.org/10.1680/stbu.2000.140.2.139.
- Lin, Z., Liu, Y. and He, J. (2014), "Behavior of stud connectors under combined shear and tension loads", Eng. Struct., 81, 362-376. https://doi.org/10.1016/j.engstruct.2014.10.016.
- Lin, Z., Liu, Y. and He, J. (2015), "Static behaviour of lying multi-stud connectors in cable-pylon anchorage zone", Steel Compos. Struct., 18(6), 1369-1389. http://dx.doi.org/10.12989/scs.2015.18.6.1369.
- Liu, X., Bradford, M.A. and Ataei, A. (2017), "Flexural performance of innovative sustainable composite steel-concrete beams", Eng. Struct., 130, 282-296. https://doi.org/10.1016/j.engstruct.2016.10.009.
- Moynihan, M.C. and Allwood, J.M. (2014), "Viability and performance of demountable composite connectors", J. Constr. Steel Res., 99, 47-56. https://doi.org/10.1016/j.jcsr.2014.03.008.
- Oberle, B., Bringezu, S., Hatfield-Dodds, S., Hellweg, S., Schandl, H., Clement, J. and Zhu, B. (2019), Global Resources Outlook.
- Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X. (2016a), "Bolted and welded connectors for the rehabilitation of composite beams", J. Constr. Steel Res., 125, 61-73. https://doi.org/10.1016/j.jcsr.2016.06.003.
- Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X. (2016b), "Flexural behaviour of composite steel-concrete beams utilising blind bolt shear connectors", Eng. Struct., 114, 181-194. https://doi.org/10.1016/j.engstruct.2016.01.057.
- Pavlovic, M., Markovic, Z., Veljkovic, M. and Budevac, D. (2013), "Bolted shear connectors vs. headed studs behaviour in pushout tests", J. Constr.l Steel Res., 88, 134-149. https://doi.org/10.1016/j.jcsr.2013.05.003.
- Rehman, N., Lam, D., Dai, X. and Ashour, A.F. (2016), "Experimental study on demountable shear connectors in composite slabs with profiled decking", J. Constr. Steel Res., 122, 178-189. https://doi.org/10.1016/j.jcsr.2016.03.021.
- Suwaed, A.S.H. and Karavasilis, T.L. (2017), "Novel Demountable Shear Connector for Accelerated Disassembly, Repair, or Replacement of Precast Steel-Concrete Composite Bridges", J. Bridge Eng., 22(9), 04017052. https://doi.org/10.1061/(ASCE)BE.1943-5592.0001080.
- Suwaed, A.S.H. and Karavasilis, T.L. (2018), "Removable shear connector for steel-concrete composite bridges", Steel Compos, Struct., 29(1), 107-123. https://doi.org/10.12989/scs.2018.29.1.107.
- Suwaed, A.S.H. and Karavasilis, T.L. (2020), "Demountable steel-concrete composite beam with full-interaction and low degree of shear connection", J. Constr. Steel Res., 171, 106152. https://doi.org/10.1016/j.jcsr.2020.106152.
- Wang, L., Webster, M.D. and Hajjar, J.F. (2019), "Pushout tests on deconstructable steel-concrete shear connections in sustainable composite beams", J. Constr. Steel Res., 153, 618-637. https://doi.org/10.1016/j.jcsr.2018.10.020.
- Wang, L., Webster, M.D. and Hajjar, J.F. (2020), "Design for Deconstruction Using Sustainable Composite Beams with Precast Concrete Planks and Clamping Connectors", J. Struct. Eng., 146(8), 1-15. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002659.
- Webster, M. and Costello, D. (2005), Designing structural systems for deconstruction: How to extend a new building's useful life and prevent it from going to waste when the end finally comes. In Proc., Green Building Conf. Atlanta.
- Xue, D.Y., Liu, Y.Q., Yu, Z. and He, J. (2012), "Static behavior of multi-stud shear connectors for steel-concrete composite bridge", J. Constr. Steel Res., 74, 1-7. https://doi.org/10.1016/j.jcsr.2011.09.017.
- Yang, F., Liu, Y., Jiang, Z. and Xin, H. (2018), "Shear performance of a novel demountable steel-concrete bolted connector under static pushout tests", Eng. Struct., https://doi.org/10.1016/j.engstruct.2018.01.005.
- Zheng, S., Liu, Y., Yoda, T. and Lin, W. (2016), "Shear behavior and analytical model of perfobond connectors", Steel Compos. Struct., 20(1), 71-89. https://doi.org/10.12989/scs.2016.20.1.071.
Cited by
- Horizontal pushout tests and parametric analyses of a locking-bolt demountable shear connector vol.35, 2022, https://doi.org/10.1016/j.istruc.2021.11.041