DOI QR코드

DOI QR Code

Non-contact monitoring of the tension in partially submerged, miter-gate diagonals

  • Eick, Brian A. (Construction Engineering Research Laboratory, U.S. Army Engineer Research and Development Center) ;
  • Smith, Matthew D. (Coastal and Hydraulics Laboratory, U.S. Army Engineer Research and Development Center) ;
  • Spencer, Billie F. (Department of Civil and Environmental Engineering, University of Illinois, Urbana-Champaign)
  • 투고 : 2020.03.09
  • 심사 : 2020.05.05
  • 발행 : 2021.02.25

초록

Miter gates are water-control structures used as the damming surface on river locks and allow the water levels in the lock to raise or lower as needed. Miter gates have channel-like cross sections and are thus prone to torsional deflection due to gravity loads. To counter-act the tendency for torsional deflection and to add torsional rigidity to the gate, slender steel members termed diagonals are added across the diagonal dimension of the gate and pre-tensioned. To maintain appropriate tension in the diagonals over their lifetime, the tension in the diagonals should be monitored; however, no such monitoring is utilized. Vibration based methods to obtain an estimate of the tensile loads in the diagonal are attractive because they are simple, inexpensive, and do not require continuous monitoring. However, employing vibration-based methods to estimate the tension in the diagonals is particularly challenging because the diagonals are subjected to varying levels of submersion in water. Finding a relationship between the frequency of vibration and applied pretension that adequately addressed the effects of submersion on diagonals is difficult. This paper proposes an approach to account for the effect of submersion on the estimated tension in miter gate diagonals. Laboratory tests are conducted using scale-model diagonal specimens subjected to various levels of tension and submersion in water. The frequency of the diagonal specimens is measured and compared to an approximation using an assumed modes model. The effects of submersion on the frequency of vibration for the partially submerged diagonals are largely explained by added mass on the diagonals. Field validation is performed using a previously developed vision-based method of extracting the frequency of vibration in conjunction with the proposed method of tension estimation of an in-service miter gate diagonal that is also instrumented with load cells. Results for the proposed method show excellent agreement with load cell measurements.

키워드

과제정보

The authors would like to thank: Yasutaka Narazaki for providing the video used for the field validation portion of this study; USACE Huntington District, in particular the personnel on site at the Greenup Lock and Dam for their assistance in the acquisition of the video used in this study; Fernando Gomez for his suggestion to try Chebyshev polynomials for the assumed modes method.

참고문헌

  1. Chen, S.S. (1985), Flow-induced vibration of circular cylindrical structures, Argonne National Laboratory, Report No. ANL-85-51, Argonne, IL, USA.
  2. Craig Jr, R.R. and Kurdila, A.J. (2006), Fundamentals of Structural Dynamics, John Wiley and Sons, Hoboken, NJ, USA.
  3. Eick, B.A., Narazaki, Y., Smith, M.D. and Spencer Jr, B.F. (2020), "Vision-based monitoring of post-tensioned diagonals on miter lock gates", J. Struct. Eng., 146(10), 04020209. 10.1061/(ASCE)ST.1943-541X.0002777
  4. Feng, D., Scarangello, T., Feng, M.Q. and Ye, Q. (2017), "Cable tension force estimate using novel noncontact vision-based sensor", Measurement, 99, 44-52. 10.1016/j.measurement.2016.12.020
  5. Hoffmann, E.G. (1944), "Torsional Deflection of Miter-Type Lock Gates and Design of the Diagonals", Master's Thesis, Washington University in St. Louis, MO, USA.
  6. Jang, S., Jo, H., Cho, S., Mechitov, K., Rice, J.A., Sim, S.H., Jung, H.J., Yun, C.B., Spencer Jr, B.F. and Agha, G. (2010), "Structural health monitoring of a cable stayed bridge using wireless smart sensor technology: data analysis", Smart Struct. Syst., Int. J., 6(5-6), 461-480. 10.12989/sss.2010.6.5_6.461
  7. Kaneko, S., Nakamura, T., Inada, F., Kato, M., Ishihara, K., Nishihara, T., Mureithi, N.W. and Langthjem, M.A. eds. (2014), Flow-Induced Vibrations: Classifications and Lessons From Practical Experiences, Elsevier, New York, NY, USA.
  8. Kim, S.W. and Kim, N.S. (2013), "Dynamic characteristics of suspension bridge hanger cables using digital image processing", NDT&E 59, 25-33. 10.1016/j.ndteint.2013.05.002
  9. Lepidi, M., Gattulli, V. and Vestroni, F. (2007), "Static and dynamic response of elastic suspended cables with damage", Int. J. Solids Struct., 44(25-26), 8194-8212. 10.1016/j.ijsolstr.2007.06.009
  10. Lepidi, M., Gattulli, V. and Vestroni, F. (2009), "Damage identification in elastic suspended cables through frequency measurement", J. Vib. Control, 15(6), 867-896. 10.1177/1077546308096107
  11. Mason, J.C. and Handscomb, D.C. (2003), Chebyshev Polynomials, Chapman & Hall/CRC, Boca Raton, FL, USA.
  12. Rao, S.S. (2007), Vibrations of Continuous Systems, John Wiley and Sons, Hoboken, NJ, USA.
  13. Riveros, G.A., Ayala-Burgos, J.L. and Dixon, D. (2017), "Numerical investigation of diagonals in miter gates: looking for the optimum prestressing", J. Perform. Constr. Facil., 31(1), 0401607. 10.1061/(ASCE)CF.1943-5509.0000896
  14. Rytter, A. (1993), "Vibration Based Inspection of Civil Engineering Structures", Thesis; Aalborg University, Denmark.
  15. Shaker, F.J. (1975), Effect of Axial Load on Mode Shapes and Frequencies of Beams (NASA TN D-8109), NASA, Washington D.C., USA.
  16. Shermer, C.L. (1957), "Stiffening lock gates by prestressing diagonals", Proceedings of the American Society of Civil Engineers, 81(9), 1-10.
  17. U.S. Army Corps of Engineers (1994), Engineering and Design: Lock Gates and Operating Equipment; EM 1110-2-2703, Washington D.C., USA.