References
- Arbyn M, Weiderpass E, Bruni L, de Sanjose S, Saraiya M, Ferlay J, et al. Estimates of incidence and mortality of cervical cancer in 2018: a worldwide analysis. Lancet Glob Health. 2020;8:e191-e203. https://doi.org/10.1016/s2214-109x(19)30482-6
- Jordaan S, Michelow P, Richter K, Simoens C, Bogers J. A review of cervical cancer in South Africa: previous, current and future. Health Care Curr Rev. 2016;4:1000180.
- Delaney G, Jacob S, Barton M. Estimation of an optimal radiotherapy utilization rate for gynecologic carcinoma: part I--malignancies of the cervix, ovary, vagina and vulva. Cancer. 2004;101:671-681. https://doi.org/10.1002/cncr.20444
- Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 2008;35:310-317. https://doi.org/10.1118/1.2818738
- Nguyen D, Pietri FJ, Sporea C, Khodri M. Patient Quality assurance of the new halcyon linear accelerator (Varian). Phys Med. 2018;56(Suppl 1):10-11.
- Smilowitz JB, Das IJ, Feygelman V, Fraass BA, Kry SF, Marshall IR, et al. AAPM medical physics practice guideline 5. a.: commissioning and QA of treatment planning dose calculations- megavoltage photon and electron beams. J Appl Clin Med Phys. 2015;16:14-34.
- Sievinen J, Ulmer W, Kaissl W. AAA photon dose calculation model in EclipseTM. Crowley: Varian Medical Systems; 2005.
- Vassiliev ON, Wareing TA, McGhee J, Failla G, Salehpour MR, Mourtada F. Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams. Phys Med Biol. 2010;55:581-598. https://doi.org/10.1088/0031-9155/55/3/002
- Akpochafor MO, Aweda MA, Durosinmi-Etti FA, Adeneye SO, Omojola AD. Simulation of the Linear Boltzmann Transport Equation in modelling of photon beam data. IOSR J Appl Phys. 2014;5:72-86. https://doi.org/10.9790/4861-0567286
- Bedford JL. Calculation of absorbed dose in radiotherapy by solution of the linear Boltzmann transport equations. Phys Med Biol. 2019;64:02TR01. https://doi.org/10.1088/1361-6560/aaf0e2
- Kumar L, Kishore V, Bhushan M, Kumar P, Chaudhary RL. Dosimetric impact of Acuros XB on cervix radiotherapy using RapidArc technique: a dosimetric study. Rep Pract Oncol Radiother. 2021;26:582-589.
- Bhagaloo V, Bhim N, Hunter A, Fakie N. A dosimetric comparison of volumetric modulated arc therapy with three-dimensional conformal radiotherapy in the treatment of cervical cancer. South Afr J Oncol. 2021;5:a149.
- Aoyama H, Westerly DC, Mackie TR, Olivera GH, Bentzen SM, Patel RR, et al. Integral radiation dose to normal structures with conformal external beam radiation. Int J Radiat Oncol Biol Phys. 2006;64:962-967. https://doi.org/10.1016/j.ijrobp.2005.11.005
- Social Science Statistics. T-test calculator for 2 independent means. Social Science Statistics, [cited 2021 Jul 22]. Available from: https://www.socscistatistics.com/tests/studentttest/default2.aspx.
- Kry SF, Feygelman V, Balter P, Knoos T, Charlie Ma CM, Snyder M, et al. AAPM task group 329: reference dose specification for dose calculations: dose-to-water or dose-to-muscle? Med Phys. 2020;47:e52-e64. https://doi.org/10.1002/mp.13709