DOI QR코드

DOI QR Code

Complications reported with the use of orthodontic miniscrews: A systematic review

  • Giudice, Antonino Lo (Department of Medical-Surgical Specialties, Section of Orthodontics, School of Dentistry, University of Catania, Policlinico Universitario V. Emanuele) ;
  • Rustico, Lorenzo (Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Section of Orthodontics, School of Dentistry, University of Messina, Policlinico Universitario G. Martino) ;
  • Longo, Miriam (Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Section of Orthodontics, School of Dentistry, University of Messina, Policlinico Universitario G. Martino) ;
  • Oteri, Giacomo (Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Section of Orthodontics, School of Dentistry, University of Messina, Policlinico Universitario G. Martino) ;
  • Papadopoulos, Moschos A. (Department of Orthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki) ;
  • Nucera, Riccardo (Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Section of Orthodontics, School of Dentistry, University of Messina, Policlinico Universitario G. Martino)
  • 투고 : 2020.05.06
  • 심사 : 2020.12.17
  • 발행 : 2021.05.25

초록

Objective: The aim of this systematic review was to evaluate the complications and side effects associated with the clinical use of orthodontic miniscrews by systematically reviewing the best available evidence. Methods: A survey of articles published up to March 2020 investigating the complications associated with miniscrew insertion, in both the maxilla and mandible, was performed using 7 electronic databases. Clinical studies, case reports, and case series reporting complications associated with the use of orthodontic miniscrew implants were included. Two authors independently performed study selection, data extraction, and risk-of-bias assessment. Results: The database survey yielded 24 articles. The risk-of-bias assessment revealed low methodological quality for the included studies. The most frequent adverse event reported was root injury with an associated periradicular lesion, vitality loss, pink discoloration of the tooth, and transitory loss of pulp sensitivity. Chronic inflammation of the soft tissue surrounding the miniscrew with mucosal overgrowth was also reported. The other adverse events reported were lesion of the buccal mucosa at the insertion site, soft-tissue necrosis, and perforation of the floor of the nasal cavity and maxillary sinus. Adverse events were also reported after miniscrew removal and included secondary bleeding, miniscrew fracture, scars, and exostosis. Conclusions: These findings highlight the need for clinicians to preliminarily assess generic and specific insertion site complications and side effects.

키워드

참고문헌

  1. Proffit WR, Fields HW, Larson BE, Sarver DM. Contemporary orthodontics. Philadelphia: Elsevier; 2019.
  2. Antoszewska-Smith J, Sarul M, Lyczek J, Konopka T, Kawala B. Effectiveness of orthodontic miniscrew implants in anchorage reinforcement during enmasse retraction: a systematic review and metaanalysis. Am J Orthod Dentofacial Orthop 2017;151:440-55. https://doi.org/10.1016/j.ajodo.2016.08.029
  3. Papadopoulos MA, Tarawneh F. The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007;103:e6-15. https://doi.org/10.1016/j.tripleo.2006.11.022
  4. Jones JP, Elnagar MH, Perez DE. Temporary skeletal anchorage techniques. Oral Maxillofac Surg Clin North Am 2020;32:27-37. https://doi.org/10.1016/j.coms.2019.08.003
  5. Papadopoulos MA, Papageorgiou SN, Zogakis IP. Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis. J Dent Res 2011;90:969-76. https://doi.org/10.1177/0022034511409236
  6. Lin L, Ahn HW, Kim SJ, Moon SC, Kim SH, Nelson G. Tooth-borne vs bone-borne rapid maxillary expanders in late adolescence. Angle Orthod 2015;85:253-62. https://doi.org/10.2319/030514-156.1
  7. Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop 2012;142:577-95.e7. https://doi.org/10.1016/j.ajodo.2012.05.016
  8. Higgins JPT, Green S. Cochrane handbook for systematic reviews of interventions version 5.1.0 [updated March 2011]. London: The Cochrane Collaboration; 2011.
  9. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, et al. The PRISMA statement for reporting systematic reviews and metaanalyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol 2009;62:e1-34. https://doi.org/10.1016/j.jclinepi.2009.06.006
  10. Wells GA, Shea B, O'Connell D, Peterson J, Welch V, Losos M, et al. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. Ottawa: University of Ottawa; 2013.
  11. Alharbi F, Almuzian M, Bearn D. Miniscrews failure rate in orthodontics: systematic review and metaanalysis. Eur J Orthod 2018;40:519-30. https://doi.org/10.1093/ejo/cjx093
  12. Reynders R, Ronchi L, Bipat S. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop 2009;135:564.e1-19; discussion 564-5. https://doi.org/10.1016/j.ajodo.2008.09.026
  13. Agrawal N, Kallury A, Agrawal K, Nair PP. Alveolar bone exostoses subsequent to orthodontic implant placement. BMJ Case Rep 2013;2013:bcr2012007951. https://doi.org/10.1136/bcr-2013-201554
  14. Al-Kharsa SS, Masoud AI. A proposed method for covering a mini-screw head while maintaining space for ligation. Int J Orthod Milwaukee 2017;28:65-6.
  15. Choi YJ, Lee DW, Kim KH, Chung CJ. Scar formation and revision after the removal of orthodontic miniscrews. Korean J Orthod 2015;45:146-50. https://doi.org/10.4041/kjod.2015.45.3.146
  16. Er K, Bayram M, Tasdemir T. Root canal treatment of a periradicular lesion caused by unintentional root damage after orthodontic miniscrew placement: a case report. Int Endod J 2011;44:1170-5. https://doi.org/10.1111/j.1365-2591.2011.01933.x
  17. Ghislanzoni LH, Berardinelli F, Ludwig B, Lucchese A. Considerations involved in placing miniscrews near the nasopalatine bundle. J Clin Orthod 2016;50:321-8.
  18. Hwang YC, Hwang HS. Surgical repair of root perforation caused by an orthodontic miniscrew implant. Am J Orthod Dentofacial Orthop 2011;139:407-11. https://doi.org/10.1016/j.ajodo.2008.11.032
  19. Lee JY, Kim PS, Choi C, Kim KB. Root repair and regeneration after miniscrew root damage. J World Fed Orthod 2016;5:70-8. https://doi.org/10.1016/j.ejwf.2016.02.005
  20. Marquezan M, de Freitas AO, Nojima LI. Miniscrew covering: an alternative to prevent traumatic lesions. Am J Orthod Dentofacial Orthop 2012;141:242-4. https://doi.org/10.1016/j.ajodo.2010.05.027
  21. McCabe P, Kavanagh C. Root perforation associated with the use of a miniscrew implant used for orthodontic anchorage: a case report. Int Endod J 2012;45:678-88. https://doi.org/10.1111/j.1365-2591.2012.02022.x
  22. Qin YJ, Zhang GD, Zhang Y, Ping YF, Zhao CY. Natural reversal of tooth discoloration and pulpal response to testing following removal of a miniscrew implant for orthodontic anchorage: a case report. Int Endod J 2016;49:402-9. https://doi.org/10.1111/iej.12459
  23. Lim G, Kim KD, Park W, Jung BY, Pang NS. Endodontic and surgical treatment of root damage caused by orthodontic miniscrew placement. J Endod 2013;39:1073-7. https://doi.org/10.1016/j.joen.2013.04.037
  24. Chen CM, Chang CS, Tseng YC, Hsu KR, Lee KT, Lee HE. The perception of pain following interdental microimplant treatment for skeletal anchorage: a retrospective study. Odontology 2011;99:88-91. https://doi.org/10.1007/s10266-010-0152-1
  25. Fah R, Schatzle M. Complications and adverse patient reactions associated with the surgical insertion and removal of palatal implants: a retrospective study. Clin Oral Implants Res 2014;25:653-8.
  26. Gurdan Z, Szalma J. Evaluation of the success and complication rates of self-drilling orthodontic miniimplants. Niger J Clin Pract 2018;21:546-52. https://doi.org/10.4103/njcp.njcp_105_17
  27. Hourfar J, Bister D, Lisson JA, Ludwig B. Incidence of pulp sensibility loss of anterior teeth after paramedian insertion of orthodontic mini-implants in the anterior maxilla. Head Face Med 2017;13:1. https://doi.org/10.1186/s13005-016-0134-9
  28. Jia X, Chen X, Huang X. Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region. Am J Orthod Dentofacial Orthop 2018;153:656-61. https://doi.org/10.1016/j.ajodo.2017.08.021
  29. Jung SA, Choi YJ, Lee DW, Kim KH, Chung CJ. Cross-sectional evaluation of the prevalence and factors associated with soft tissue scarring after the removal of miniscrews. Angle Orthod 2015;85:420-6. https://doi.org/10.2319/101813-772.1
  30. Takaki T, Tamura N, Yamamoto M, Takano N, Shibahara T, Yasumura T, et al. Clinical study of temporary anchorage devices for orthodontic treatment--stability of micro/mini-screws and miniplates: experience with 455 cases. Bull Tokyo Dent Coll 2010;51:151-63. https://doi.org/10.2209/tdcpublication.51.151
  31. Ziebura T, Flieger S, Wiechmann D. Mini-implants in the palatal slope--a retrospective analysis of implant survival and tissue reaction. Head Face Med 2012;8:32. https://doi.org/10.1186/1746-160X-8-32
  32. Motoyoshi M, Sanuki-Suzuki R, Uchida Y, Saiki A, Shimizu N. Maxillary sinus perforation by orthodontic anchor screws. J Oral Sci 2015;57:95-100. https://doi.org/10.2334/josnusd.57.95
  33. Shinohara A, Motoyoshi M, Uchida Y, Shimizu N. Root proximity and inclination of orthodontic miniimplants after placement: cone-beam computed tomography evaluation. Am J Orthod Dentofacial Orthop 2013;144:50-6. https://doi.org/10.1016/j.ajodo.2013.02.021
  34. Fabbroni G, Aabed S, Mizen K, Starr DG. Transalveolar screws and the incidence of dental damage: a prospective study. Int J Oral Maxillofac Surg 2004;33:442-6. https://doi.org/10.1016/j.ijom.2003.10.014
  35. Wang Z, Zhang D, Liu Y, Zhao Z. Buccal mucosal lesions caused by the interradicular miniscrew: a preliminary report. Int J Oral Maxillofac Implants 2010;25:1183-8.
  36. Gracco A, Tracey S, Baciliero U. Miniscrew insertion and the maxillary sinus: an endoscopic evaluation. J Clin Orthod 2010;44:439-43.
  37. Nucera R, Bellocchio AM, Oteri G, Farah AJ, Rosalia L, Giancarlo C, et al. Bone and cortical bone characteristics of mandibular retromolar trigone and anterior ramus region for miniscrew insertion in adults. Am J Orthod Dentofacial Orthop 2019;155:330-8. https://doi.org/10.1016/j.ajodo.2018.04.025
  38. Nucera R, Lo Giudice A, Bellocchio AM, Spinuzza P, Caprioglio A, Perillo L, et al. Bone and cortical bone thickness of mandibular buccal shelf for mini-screw insertion in adults. Angle Orthod 2017;87:745-51. https://doi.org/10.2319/011117-34.1
  39. Liou EJ, Pai BC, Lin JC. Do miniscrews remain stationary under orthodontic forces? Am J Orthod Dentofacial Orthop 2004;126:42-7. https://doi.org/10.1016/j.ajodo.2003.06.018
  40. Kuroda S, Yamada K, Deguchi T, Hashimoto T, Kyung HM, Takano-Yamamoto T. Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop 2007;131(4 Suppl):S68-73. https://doi.org/10.1016/j.ajodo.2006.06.017
  41. Tronstad L. Root resorption--etiology, terminology and clinical manifestations. Endod Dent Traumatol 1988;4:241-52. https://doi.org/10.1111/j.1600-9657.1988.tb00642.x
  42. Renjen R, Maganzini AL, Rohrer MD, Prasad HS, Kraut RA. Root and pulp response after intentional injury from miniscrew placement. Am J Orthod Dentofacial Orthop 2009;136:708-14. https://doi.org/10.1016/j.ajodo.2007.12.031
  43. Carano A, Velo S, Leone P, Siciliani G. Clinical applications of the Miniscrew Anchorage System. J Clin Orthod 2005;39:9-24; quiz 29-30.
  44. Suzuki EY, Buranastidporn B. An adjustable surgical guide for miniscrew placement. J Clin Orthod 2005;39:588-90.
  45. Poggio PM, Incorvati C, Velo S, Carano A. "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod 2006;76:191-7.
  46. Carano A, Velo S, Incorvati C, Poggio P. Clinical applications of the Mini-Screw-Anchorage-System (M.A.S.) in the maxillary alveolar bone. Prog Orthod 2004;5:212-35.
  47. Reicheneder C, Rottner K, Bokan I, Mai R, Lauer G, Richter G, et al. Mechanical loading of orthodontic miniscrews - significance and problems: an experimental study. Biomed Tech (Berl) 2008;53:242-5. https://doi.org/10.1515/bmt.2008.038
  48. Kyung HM, Park HS, Bae SM, Sung JH, Kim IB. Development of orthodontic micro-implants for intraoral anchorage. J Clin Orthod 2003;37:321-8; quiz 314.
  49. Smith A, Hosein YK, Dunning CE, Tassi A. Fracture resistance of commonly used self-drilling orthodontic mini-implants. Angle Orthod 2015;85:26-32. https://doi.org/10.2319/112213-860.1
  50. Chen Y, Kyung HM, Gao L, Yu WJ, Bae EJ, Kim SM. Mechanical properties of self-drilling orthodontic micro-implants with different diameters. Angle Orthod 2010;80:821-7. https://doi.org/10.2319/103009-607.1
  51. Lim SA, Cha JY, Hwang CJ. Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length. Angle Orthod 2008;78:234-40. https://doi.org/10.2319/121206-507.1
  52. Wilmes B, Rademacher C, Olthoff G, Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 2006;67:162-74. https://doi.org/10.1007/s00056-006-0611-z
  53. Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA. Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod 2011;45:433-41; quiz 467.
  54. Winsauer H, Vlachojannis C, Bumann A, Vlachojannis J, Chrubasik S. Paramedian vertical palatal bone height for mini-implant insertion: a systematic review. Eur J Orthod 2014;36:541-9. https://doi.org/10.1093/ejo/cjs068
  55. Lo Giudice A, Quinzi V, Ronsivalle V, Martina S, Bennici O, Isola G. Description of a digital work-flow for CBCT-guided construction of micro-implant supported maxillary skeletal expander. Materials (Basel) 2020;13:1815. https://doi.org/10.3390/ma13081815
  56. Yoon S, Lee DY, Jung SK. Influence of changing various parameters in miniscrew-assisted rapid palatal expansion: a three-dimensional finite element analysis. Korean J Orthod 2019;49:150-60. https://doi.org/10.4041/kjod.2019.49.3.150
  57. Hourfar J, Ludwig B, Bister D, Braun A, Kanavakis G. The most distal palatal ruga for placement of orthodontic mini-implants. Eur J Orthod 2015;37:373-8. https://doi.org/10.1093/ejo/cju056
  58. Liou EJ, Chen PH, Wang YC, Lin JC. A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical implications for miniscrew insertion. Am J Orthod Dentofacial Orthop 2007;131:352-6. https://doi.org/10.1016/j.ajodo.2005.04.044
  59. Baumgaertel S, Hans MG. Assessment of infrazygomatic bone depth for mini-screw insertion. Clin Oral Implants Res 2009;20:638-42. https://doi.org/10.1111/j.1600-0501.2008.01691.x
  60. Kravitz ND, Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop 2007;131(4 Suppl):S43-51. https://doi.org/10.1016/j.ajodo.2006.04.027

피인용 문헌

  1. Guided Insertion of Temporary Anchorage Device in Form of Orthodontic Titanium Miniscrews with Customized 3D Templates-A Systematic Review with Meta-Analysis of Clinical Studies vol.11, pp.12, 2021, https://doi.org/10.3390/coatings11121488