DOI QR코드

DOI QR Code

Analytical behavior of built-up square concrete-filled steel tubular columns under combined preload and axial compression

  • Wang, Jian-Tao (Department of Civil Engineering, Tsinghua University) ;
  • Wang, Fa-Cheng (Department of Civil Engineering, Tsinghua University)
  • Received : 2020.08.31
  • Accepted : 2021.03.09
  • Published : 2021.03.25

Abstract

This paper numerically investigated the behavior of built-up square concrete-filled steel tubular (CFST) columns under combined preload and axial compression. The finite element (FE) models of target columns were verified in terms of failure mode, axial load-deformation curve and ultimate strength. A full-range analysis on the axial load-deformation response as well as the interaction behavior was conducted to reveal the composite mechanism. The parametric study was performed to investigate the influences of material strengths and geometric sizes. Subsequently, influence of construction preload on the full-range behavior and confinement effect was investigated. Numerical results indicate that the axial load-deformation curve can be divided into four working stages where the contact pressure of curling rib arc gradually disappears as the steel tube buckles; increasing width-to-thickness (B/t) ratio can enhance the strength enhancement index (e.g., an increment of 1.88% from B/t=40 to B/t=100), though ultimate strength and ductility are decreased; stiffener length and lip inclination angle display a slight influence on strength enhancement index and ductility; construction preload can degrade the plastic deformation capacity and postpone the origin appearance of contact pressure, thus making a decrease of 14.81%~27.23% in ductility. Finally, a revised equation for determining strain εscy corresponding to ultimate strength was proposed to evaluate the plastic deformation capacity of built-up square CFST columns.

Keywords

References

  1. Cai, J. and He, Z.Q. (2006), "Axial load behavior of square CFT stub column with binding bars", J. Constr. Steel Res., 62(5), 472-483. https://doi.org/10.1016/j.jcsr.2005.09.010.
  2. Chen, Z.Y., Qin, X.Q., Shen, Z.Y. and Chen, G.J. (2003), "Test of the lateral pressure of the wall of concrete-filled rectangular steel columns at construction stage", Build. Struct., 33(7), 27-28. (in Chinese)
  3. Ellobody, E. (2007), "Nonlinear behavior of concrete-filled stainless steel stiffened slender tube columns", Thin-walled Struct., 45(3), 259-273. https://doi.org/10.1016/j.tws.2007.02.011.
  4. Ge, H. and Usami, T. (1992), "Strength of concrete-filled thin-walled steel box columns: experiment", J. Struct. Eng., 118(11), 3036-3054. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:11(3036).
  5. Han, L.H. (2016), Concrete Filled Steel Tubular Structures--Theory and Practice (Third Edition), Science Press, Beijing, China. (in Chinese)
  6. Han, L.H. and Yang, Y.F. (2007), Modern concrete filled steel tube structure technology, China Architecture & Building Press, Beijing, China. (in Chinese)
  7. Han, L.H., Li, W., Wang, W.D. and Tao, Z. (2017), Advanced Composite and Mixed Structures: Testing, Theory and Design Approach (Second Edition), Science Press, Beijing, China. (in Chinese)
  8. Hillerborg, A., Modeer, M. and Petersson, P.E. (1976), "Analysis of crack formation and crack growth in concrete by means of fracture mechanics and finite elements", Cem. Concr. Res., 6(6), 773-781. https://doi.org/10.1016/0008-8846(76)90007-7.
  9. Hou, C. and Han, L.H. (2017), "Analytical behaviour of CFDST chord to CHS brace composite K-joints", J. Constr. Steel Res., 128, 618-632. https://doi.org/10.1016/j.jcsr.2016.09.027.
  10. Huang, C.S., Yeh, Y.K., Liu, G.Y., Hu, H.T., Tsai, K.C., Weng, Y. T., Wang, S.H. and Wu, M.H. (2002), "Axial load behavior of stiffened concrete-filled steel columns", J. Struct. Eng., 128(9), 1222-1230. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:9(1222).
  11. Kim, S.H., Yom, K.S. and Choi, S.M. (2015), "A study on the structural performance of new shape built-up square column under concentric axial load", Steel Compos. Struct., 18(6), 1451-1464. https://doi.org/10.12989/scs.2015.18.6.1451.
  12. Kitada, T. (1998), "Ultimate strength and ductility of state-of-the-art concrete-filled steel bridge piers in Japan", Eng. Struct., 20(4-6), 347-354. https://doi.org/10.1016/S0141-0296(97)00026-6.
  13. Lai, B., Liew, J.Y. and Xiong, M. (2019), "Experimental and analytical investigation of composite columns made of high strength steel and high strength concrete", Steel Compos. Struct., 33(1), 67-79. https://doi.org/10.12989/scs.2019.33.1.067.
  14. Lee, K.C. and Yoo, C.H. (2012), "Longitudinal stiffeners in concrete-filled tubes", J. Struct. Eng., 138(6), 753-758. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000526.
  15. Lee, S.H., Choi, Y.H., Kim, Y.H. and Choi, S.M. (2012), "Structural performance of welded built-up square CFST stub columns", Thin-Wall. Struct., 52, 12-20. https://doi.org/10.1016/j.tws.2011.09.003.
  16. Lee, S.H., Kim, S.H., Kim, Y. H., Tao, Z. and Choi, S. M. (2011), "Water-pressure test and determination of welding-throat-depth for welded built-up square CFST column", J. Constr. Steel Res., 67(7), 1065-1077. https://doi.org/10.1016/j.jcsr.2011.02.012.
  17. Li, G., Hou, C., Han, L.H. and Shen, L. (2020), "Numerical study of concrete-encased CFST under preload followed by sustained service load", Steel Compos. Struct., 35(1), 93-109. https://doi.org/10.12989/scs.2020.35.1.093.
  18. Liang, W., Dong, J. and Wang, Q. (2018), "Axial compressive behavior of concrete-filled steel tube columns with stiffeners", Steel Compos. Struct., 29(2), 151-159. https://doi.org/10.12989/scs.2018.29.2.151.
  19. Morishita, Y. (1979), "Experimental studies on bond strength in concrete filled circular steel tubular columns subjected to axial loads", Trans. Japan Concr. Inst., 1, 351-358.
  20. Morishita, Y. (1982), "Experimental Studies on Bond Strength between Square Steel Tube in Concrete Filled and Encased Concrete Core under Cyclic Shearing Force and Constant Axial Force", Trans. Japan Concr. Inst., 4, 363-370.
  21. Mursi, M. and Uy, B. (2003), "Strength of concrete filled steel box columns incorporating interaction buckling", J. Struct. Eng., 129(5), 626-639. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:5(626).
  22. Patel, V.I., Liang, Q.Q. and Hadi, M.N. (2013), "Numerical analysis of circular concrete-filled steel tubular slender beam-columns with preload effects", Int. J. Struct. Stab. Dyn., 13(03), 1250065. https://doi.org/10.1142/S0219455412500654.
  23. Ren, W., Sneed, L.H., Yang, Y. and He, R. (2015), "Numerical simulation of prestressed precast concrete bridge deck panels using damage plasticity model", Int. J. Concr. Struct. Mater., 9(1), 45-54. https://doi.org/10.1007/s40069-014-0091-2.
  24. Shi, Y.J., Wang, M. and Wang, Y.Q. (2012), "Study on constitutive model of structural steel under cyclic loading", Eng. Mech., 29(9), 92-98. (in Chinese)
  25. Sun, Q., Qu, S. and Wu, X. (2019), "Ultimate load capacity analysis of Q690 high-strength steel KK-type tube-gusset plate connections", J. Struct. Eng., 145(8), 04019074. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002363.
  26. Susantha, K.A.S., Ge, H. and Usami, T. (2001), "Confinement evaluation of concrete-filled box-shaped steel columns", Steel Compos. Struct., 1(3), 313-328. https://doi.org/10.12989/scs.2001.1.3.313.
  27. T/CCES 7-2020 (2020), Technical specification for concrete-filled double skin steel tubular structures, China Civil Engineering Society; Beijing, China. (in Chinese)
  28. T/CECS 663-2020 (2020), Technical specification for concrete-encased concrete-filled steel tubular structures, China Association for Engineering Construction Standardization; Beijing, China. (in Chinese)
  29. Tang, G.Q., Xiao, Y. and Zhang, Y.T. (2015), "Study of bearing capacity and complete stress-strain curves for concrete filled square steel tube columns", Eng. Mech., 32(8), 103-111. (in Chinese)
  30. Tao, Z., Han, L.H. and Wang, D.Y. (2007), "Experimental behaviour of concrete-filled stiffened thin-walled steel tubular columns", Thin-Wall. Struct., 45(5), 517-527. https://doi.org/10.1016/j.tws.2007.04.003.
  31. Tao, Z., Han, L.H. and Wang, Z.B. (2005), "Experimental behaviour of stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns", J. Constr. Steel Res., 61(7), 962-983. https://doi.org/10.1016/j.jcsr.2004.12.003.
  32. Tao, Z., Uy, B., Han, L.H. and Wang, Z.B. (2009), "Analysis and design of concrete-filled stiffened thin-walled steel tubular columns under axial compression", Thin-Wall. Struct., 47(12), 1544-1556. https://doi.org/10.1016/j.tws.2009.05.006.
  33. Wang, F.C., Han, L.H. and Li, W. (2018), "Analytical behavior of CFDST stub columns with external stainless steel tubes under axial compression", Thin-Wall. Struct., 127, 756-768. https://doi.org/10.1016/j.tws.2018.02.021.
  34. Wang, F.C., Zhao, H.Y. and Han, L.H. (2019a), "Analytical behavior of concrete-filled aluminum tubular stub columns under axial compression", Thin-Wall. Struct., 140, 21-30. https://doi.org/10.1016/j.tws.2019.03.019.
  35. Wang, J., Sun, Q. and Li, J. (2019b), "Experimental study on seismic behavior of high-strength circular concrete-filled thin-walled steel tubular columns", Eng. Struct., 182, 403-415. https://doi.org/10.1016/j.engstruct.2018.12.098.
  36. Wang, J., Sun, Q., Wu, X. and Wu, Y. (2019c), "Experimental and analytical investigation on seismic behavior of Q690 circular high-strength concrete-filled thin-walled steel tubular columns", Struct. Des. Tall Spec. Build., 28(5), e1583. https://doi.org/10.1002/tal.1583.
  37. Wang, N. and Lee, M.J. (2015), "Structural behavior of beam-to-column connections of circular CFST columns by using mixed diaphragms", Int. J. Steel Struct., 15(2), 347-364. https://doi.org/10.1007/s13296-015-6007-4.
  38. Wang, Y., Yang, Y. and Zhang, S. (2012), "Static behaviors of reinforcement-stiffened square concrete-filled steel tubular columns", Thin-walled Struct., 58, 18-31. https://doi.org/10.1016/j.tws.2012.04.015.
  39. Wang, Z.B., Tao, Z. and Yu, Q. (2017), "Axial compressive behaviour of concrete-filled double-tube stub columns with stiffeners", Thin-Wall. Struct., 120, 91-104. https://doi.org/10.1016/j.tws.2017.08.025.
  40. Xu, B., Wu, F. and Xu, G. (2018), "Mechanism study on the axial compressive performance of short square CFST columns with different stiffeners", Adv. Civ. Eng., 2018, 1-10. https://doi.org/10.1155/2018/9109371.
  41. Yang, Y., Wang, Y. and Fu, F. (2014), "Effect of reinforcement stiffeners on square concrete-filled steel tubular columns subjected to axial compressive load", Thin-Wall. Struct., 82, 132-144. https://doi.org/10.1016/j.tws.2014.04.009.
  42. Zand, A.W.A., BadaruZZaman, W.H., Ali, M.M., Hasan, Q.A. and Al-Shaikhli, M. S. (2020), "Flexural performance of cold-formed square CFST beams strengthened with internal stiffeners", Steel Compos. Struct., 34(1), 123-139. https://doi.org/10.12989/scs.2020.34.1.123.
  43. Zhang, Y., Xu, C. and Lu, X. (2007), "Experimental study of hysteretic behaviour for concrete-filled square thin-walled steel tubular columns", J. Constr. Steel Res., 63(3), 317-325. https://doi.org/10.1016/j.jcsr.2006.04.014.
  44. Zhou, S.M. (2019), "Mechanical behavior of concrete filled high-strength thin-walled steel tubular members", Ph.D. Dissertation, Xi'an Jiaotong University, Xi'an. (in Chinese)
  45. Zhou, Z., Gan, D. and Zhou, X. (2019), "Improved composite effect of square concrete-filled steel tubes with diagonal binding ribs", J. Struct. Eng., 145(10), 04019112. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002400.

Cited by

  1. Axial Compression Behavior of Circular Concrete-Filled High-Strength Thin-Walled Steel Tubular Columns with Out-of-Code D/t Ratios vol.2021, 2021, https://doi.org/10.1155/2021/9081566
  2. Numerical Assessment on the Dynamic Behaviour of Submarine Hoses Attached to CALM Buoy Configured as Lazy-S under Water Waves vol.9, pp.10, 2021, https://doi.org/10.3390/jmse9101130