DOI QR코드

DOI QR Code

Component based moment-rotation model of composite beam blind bolted to CFDST column joint

  • Guo, Lei (School of Civil Engineering, Hefei University of Technology) ;
  • Wang, Jingfeng (School of Civil Engineering, Hefei University of Technology) ;
  • Wang, Wanqian (School of Civil Engineering, Hefei University of Technology) ;
  • Ding, Zhaodong (School of Civil Engineering, Hefei University of Technology)
  • 투고 : 2019.11.04
  • 심사 : 2021.02.20
  • 발행 : 2021.03.10

초록

This paper aims to explore the mechanical behavior and moment-rotation model of blind bolted joints between concrete-filled double skin steel tubular columns and steel-concrete composite beams. For this type of joint, the inner tube and sandwiched concrete were additionally identified as basic components compared with CFST blind bolted joint. A modified moment-rotation model for this type of connection was developed, of which the compatibility condition and mechanical equilibrium were employed to determine the internal forces of basic components and neutral axis. Following this, load transfer mechanism among the inner tube, sandwiched concrete and outer tube was discussed to assert the action area of the components. Subsequently, assembly processes of basic coefficients in terms of their stiffness and resistances based on the component method by simplifying them as assemblages of springs in series or in parallel. Finally, an experimental investigation on four substructure joints with CFDST columns for validation purposes was carried out to capture the connection details. The predicted results derived from the mechanical models coincided well with the experimental results. It is demonstrated that the proposed mechanical model is capable of evaluating the complete moment-rotation relationships of blind bolted CFDST column composite connections.

키워드

참고문헌

  1. ACI 318M (2011), Building code requirements for structural concrete (ACI318M-11) and commentary, American Concrete Institute; Farmington Hills, MI, USA.
  2. Agheshlui, H. (2014), "Anchored blind bolted connections within concrete filled square steel hollow section columns", Ph.D. Dissertation, The University of Melbourne, Melbourne.
  3. Agheshlui, H., Goldsworthy, H., Gad, E. and Mirza O. (2017), "Anchored blind bolted composite connection to a concrete filled steel tubular column", Steel Compos. Struct., 23, 115-130. https://doi.org/10.12989/scs.2017.23.1.115.
  4. Aribert, J.M. (1996), "Influence of slip of the shear connection on composite joint behavior", Proceedings of the 3rd International Workshop on Connections in Steel Structures, Pergamon, Trento, October.
  5. Aribert, J.M. and Dinga, O.N. (2000), "Modeling and experimental investigation of bolted flush endplate composite beam-to-column joints", Comp Construction in Steel and Concrete, 711-724. https://doi.org/10.1061/40616(281)62.
  6. ATC-24 (1992), Guidelines for cyclic seismic testing of components of steel structures, Applied Technology Council; Redwood City, America.
  7. Bennacer, M.A., Beroual, A., Kriker, A. and Demonceau, J.F. (2015), "Analytical model for composite joints under sagging moment", Eng. Struct., 101, 399-411. https://doi.org/10.1016/j.engstruct.2015.07.024.
  8. CEB-FIP Model Code (1990), Design Code, Committee Euro-International du Beton, Lausanne, Thomas Telford Services Ltd; London, England.
  9. Ding, C.T., Pan, X.B., Bai, Y. and Shi, G. (2019), " Prefabricated connection for steel beam and concrete-filled steel tube column", J. Constr. Steel Res., 162, 105751. https://doi.org/10.1016/j.jcsr.2019.105751.
  10. Dong, C.X. and Ho, J.C.M. (2012), "Uni-axial behaviour of normal-strength CFDST column with external steel rings", Steel Compos. Struct., 13(6), 587-606. https://doi.org/10.12989/scs.2012.13.6.587.
  11. EC 3 (2005), Design of steel structures-Part 1-8: Design of joints, European Committee for Standardisation (CEN); Brussels, Belgium.
  12. EC 4 (2004), Design of composite steel and concrete structures-Part 1-1: Composite joints in frames for buildings. European Committee for Standardisation (CEN); Brussels, Belgium.
  13. Fukumoto, T. and Morita, K. (2005), "Elastoplastic Behavior of Panel Zone in Steel Beam-to-Concrete Filled Steel Tube Column Moment Connections", J. Struct. Eng., 131(12), 1841-1853. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:12(1841).
  14. GB50017 (2017), Code for design of steel structures, Ministry of Housing and Urban-Rural Development; Beijing: China
  15. Guo, L., Wang, J.F. and Zhang, M. (2020), "Modelling and experiment of semi rigid joint between composite beam and square CFDST column", Steel Compos. Struct., 34, 803-818. DOI: https://doi.org/10.12989/scs.2020.34.6.803
  16. Han, L.H., Huang, H., Tao, Z. and Zhao, X.L. (2006), "Concrete-filled double skin steel tubular (CFDST) beam-columns subjected to cyclic bending", Eng. Struct., 28(12), 1698-714. https://doi.org/10.1016/j.engstruct.2006.03.004.
  17. Han, L.H., Tao, Z., Huang, H. and Zhao, X.L. (2004), "Concrete-filled double skin (SHS outer and CHS inner) steel tubular beam-columns", Thin-Wall. Struct., 42(9), 1329-1355. https://doi.org/10.1016/j.tws.2004.03.017.
  18. Hanswille, G. (1997), "Cracking of concrete mechanical models of the design rules in Eurocode 4", Comp Construction in Steel and Concrete, 421-433.
  19. Li, B.Y., Yang, Y.L., Chen Y.F., Cheng, W. and Zhang, L.B. (2018), "Behavior of connections between square CFST columns and H-section steel beams". J. Constr. Steel Res., 145, 10-27. https://doi.org/10.1016/j.jcsr.2018.02.005.
  20. Li, W., Han, L.H. and Zhao X.L. (2015), "Behaviors of CFDST stub columns under preload, sustained load and chloride corrosion", J. Constr. Steel Res., 107, 12-23. https://doi.org/10.1016/j.jcsr.2014.12.023.
  21. Li, X., Xiao, Y. and Wu, Y.T. (2009), "Seismic behavior of exterior connections with steel beams bolted to CFT columns", J. Constr. Steel Res., 65, 1438-1446. https://doi.org/10.1016/j.jcsr.2009.03.009.
  22. Liu J.C., Yang Y.L., Liu, J.P. and Zhou X.H. (2017), "Experimental investigation of special-shaped concrete-filled steel tubular column to steel beam connections under cyclic loading", Eng Struct., 151, 68-84. https://doi.org/10.1016/j.engstruct.2017.07.021.
  23. Liu, Y., Chuquitaype, M. and Elghazouli, A.Y. (2012), "Response and component characterisation of semi-rigid connections to tubular columns under axial loads", Eng. Struct., 41, 510-532. https://doi.org/10.1016/j.engstruct.2012.03.061.
  24. Oktavianus, Y., Chang, H.F., Goldsworthy, H.M. and Gad, E.F. (2017), "Component model for pull-out behaviour of headed anchored blind bolt within concrete filled circular hollow section", Eng. Struct., 148, 210-224. https://doi.org/10.1016/j.engstruct.2017.06.056.
  25. Pitrakkos, T. and Tizani, W. (2017), " A component method model for blind-bolts with headed anchors in tension", Steel Compos. Struct., 18, 13055-1330. https://doi.org/10.12989/scs.2015.18.5.1305.
  26. Ren, Q.X., Hou, C., Lam, D. and Han, L.H. (2014), "Experiments on the bearing capacity of tapered concrete filled double skin steel tubular (CFDST) stub columns", Steel Compos. Struct., 17(5), 665-684. https://doi.org/10.12989/scs.2014.17.5.667.
  27. Satasivam, S., Feng, P., Bai, Y. and Caprani, C. (2017), "Composite actions within steel-FRP composite beam systems with novel blind bolt shear connections", Eng. Struct., 138, 63-73. https://doi.org/10.1016/j.engstruct.2017.01.068.
  28. Shekastehband, B., Mohammadbagheri, S. and Taromi, A. (2018), "Seismic behavior of stiffened concrete-filled double-skin tubular columns", Steel Compos. Struct., 27(5), 577-598. https://doi.org/10.12989/scs.2018.27.5.577.
  29. Stylianidis, P.M. and Nethercot, D.A. (2015), "Modelling of connection behavior for progressive collapse analysis", J. Constr. Steel Res., 113, 169-184. https://doi.org/10.1016/j.jcsr.2015.06.008.
  30. Tao Z., Hassan, M.K., Song, T.Y. and Han, L.H. (2017), "Experimental study on blind bolted connections to concrete-filled stainless steel columns", J. Constr. Steel Res., 128, 825-838. https://doi.org/10.1016/j.jcsr.2016.10.016.
  31. Thai, H.T. and Brain, U. (2016), "Rotational stiffness and moment resistance of bolted endplate joints with hollow or CFST columns", J. Constr. Steel Res., 126, 139-152. https://doi.org/10.1016/j.jcsr.2016.07.005.
  32. Wan, C.Q., Bai, Y., Ding, C.T., Zhu, L. and Yang L. (2020), "Mechanical performance of novel steel one-sided bolted joints in shear", J Constr Steel Res., 165, 105815. https://doi.org/10.1016/j.jcsr.2019.105815
  33. Wan, C.Y. and Zha, X.X. (2016), "Nonlinear analysis and design of concrete-filled dual steel tubular columns under axial loading", Steel Compos. Struct., 20(3), 571-597. https://doi.org/10.12989/scs.2016.20.3.571.
  34. Wang, F.C., Han, L.H. and Li, W. (2018), "Analytical behavior of CFDST stub columns with external stainless steel tubes under axial compression", Thin-Walled Struct., 127, 756-768. https://doi.org/10.1016/j.tws.2018.02.021.
  35. Wang, J., Chen, X.F., Wu, C. and Hou, C.C. (2019), "Analytical behavior of dodecagonal concrete-filled double skin tubular (CFDST) columns under axial compression", J. Constr. Steel Res., 162, 105743. https://doi.org/10.1016/j.jcsr.2019.105743.
  36. Wang, J.F., Wang, J.X. and Wang, H.T. (2017), "Seismic behavior of blind bolted CFST frames with semi-rigid connections", Struct., 9, 91-104. https://doi.org/10.1016/j.istruc.2016.10.001.
  37. Wang, J.F., Zhang, H.J. and Jiang, Z. (2016), "Seismic behavior of blind bolted end plate composite joints to CFTST columns", Thin-Wall. Struct., 108, 256-269. https://doi.org/10.1016/j.tws.2016.08.013.
  38. Wang, W., Li, L. and Chen, D.B. (2018), "Progressive collapse behaviour of endplate connections to cold-formed tubular column with novel Slip-Critical Blind Bolts", Thin-Wall. Struct., 131, 404-416. https://doi.org/10.1016/j.tws.2018.07.012.
  39. Wang, Z.B., Tao, Z., Li, D.S. and Han, L.H. (2016), "Cyclic behaviour of novel blind bolted joints with different stiffening elements", Thin-Wall. Struct., 101, 157-168. https://doi.org/10.1016/j.tws.2016.01.007.
  40. Wang, Z.Y., Tizani, W. and Wang, Q.Y. (2010), "Strength and initial stiffness of a blind-bolt connection based on the T-stub model", Eng. Struct., 32, 2505-2517. https://doi.org/10.1016/j.engstruct.2010.04.005.
  41. Wu, C., Bai, Y. and Mottram, T. (2016), " Effect of elevated temperatures on the mechanical performance of pultruded FRP joints with a single ordinary or blind bolt.", J. Compos. Constr., 20(2), 04015045. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000608.
  42. Yang, Y.F. and Han, L.H. (2009), "Experiments on rectangular concrete-filled steel tubes loaded axially on a partially stressed cross-sectional area", J. Constr. Steel Res., 65, 1617-1630. https://doi.org/10.1016/j.jcsr.2009.04.004.
  43. Yang, Y.F., Hou, C., Meng, C.Y. and Han, L.H. (2015), "Investigation on square concrete filled double-skin steel tube (CFDST) subjected to local bearing force: Experiments", Thin-Wall. Struct., 94, 394-409. https://doi.org/10.1016/j.tws.2015.04.026.
  44. Yeomans, N. (1994), "I-beam/rectangular hollow section column connections using the Flowdrill system", Tub Struct., VI, 381-8.
  45. Zhou, F. and Ben, Y. (2018), "Concrete-filled double-skin aluminum circular hollow section stub columns", Thin-Wall. Struct., 133, 141-152. https://doi.org/10.1016/j.tws.2018.09.037.