참고문헌
- Ban, S. (1941), "Study on statics for structures of temple and shrine part-1", Technical Papers of Annual Meeting, Architectural Institute of Japan (A.I.J), 252-258.
- Chang, W.S. and Hsu, M.F. (2007), "Rotational performance of traditional Nuki joints with gap II: the behavior of butted Nuki joint and its comparison with continuous Nuki joint", J. Wood Sci., 53(5), 401-407. https://doi.org/10.1007/s10086-007-0880-1
- Chang, W.S., Hsu, M.F. and Komatsu, K. (2006), "Rotational performance of traditional Nuki joints with gap I: Theory and verification", J. Wood Sci., 52(1), 58-62. https://doi.org/10.1007/s10086-005-0734-7.
- Chen, C.C. and Qiu, H.X. (2016), "Flexural behavior of penetrated mortise-tenon joints", J. Southeast Univ. (Nat. Sci. Ed.), 46(2), 326-334.
- Chen, Z.Y., Zhu, E.C. and Pan, J.L. (2011), "Numerical simulation of mechanical behaviour of wood under complex stress", Chin. J. Comput. Mech., 28(4), 629-635.
- Guan, Z.W., Kitamori, A. and Komatsu, K. (2008), "Experimental study and finite element modelling of Japanese "Nuki" joints-Part one: Initial stress states subjected to different wedge configurations", Eng. Struct., 30(6), 2032-2040. https://doi.org/10.1016/j.engstruct.2008.01.003.
- Guan, Z.W., Kitamori, A. and Komatsu, K. (2008), "Experimental study and finite element modelling of Japanese "Nuki" joints-Part two: Racking resistance subjected to different wedge configurations", Eng. Struct., 30(7), 2041-2049. https://doi.org/10.1016/j.engstruct.2008.01.004.
- Hayashi, T. (1998), "Restoring properties of Japanese traditional wooden frame", Proc., World Conf. on Timber Engrg., Presses Polytechniques et Universitaires Romandes, Montreux, Switzerland.
- ISO-16670 (2003), Timber Structures: Joints Made with Mechanical Fasteners: Qusai-Static Reversed-Cyclic Test Method, International Organization for Standardization, Geneva.
- Kawai, N. (1996), "Column rocking resistance in Japanese timber building", International Wood Conference, 183-190.
- King, W.S., Yen, J.Y. and Yen, Y.N. (1996), "Joint characteristics of traditional Chinese wooden frames", Eng. Struct., 18(8), 635-644. https://doi.org/10.1016/0141-0296(96)00203-9.
- Lee, D., Araki, Y., Endo, T., Yoshida, N. and Uetani, K. (2009), "Modelling of column base for traditional timber buildings based on local compression experiments at contact surface between column base and foundation stone", J. Struct. Constr. Eng., 74(639), 865-872. https://doi.org/10.3130/aijs.74.865
- Li, J. (2006), Ying-Tsao-Fa-Shih, China Bookstore Press, Beijing, P.R. China.
- Li, Y.Z., Cao, S.Y. and Xue, J.Y. (2016), "Analysis on mechanical behavior of dovetail mortise-tenon joints with looseness in traditional timber buildings", Struct. Eng. Mech., 60(5), 903-921. http://dx.doi.org/10.12989/sem.2016.60.5.903.
- Maeno, M., Saito, S. and Suzuki, Y. (2007), "Evaluation of equilibrium of force acting on column and restoring force due to column rocking by full scale tests of traditional wooden frames", J. Struct. Constr. Eng., 153-160.
- Maeno, M., Suzuki, Y., Ohshita, T. and Kitahara, A. (2004), "Seismic response characteristics of traditional wooden frame by full-scale dynamic and static tests", The 13th World Conference on Earthquake Engineering, Vancouver, B.C., August.
- Sandberg, L.B., Bulleit, W.M. and Reid, E.H. (2000), "Strength and stiffness of oak pegs in traditional timber-frame joints", J. Struct. Eng., 126(6), 717-723. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:6(717).
- Santana, C.L.O. and Mascia, N.T. (2009), "Wooden framed structures with semi-rigid connections: Quantitative approach focused on design needs", Struct. Eng. Mech., 31(3), 315-331. http://dx.doi.org/10.12989/sem.2009.31.3.315.
- Wan, J. (2015), "Static and dynamic FE analyses of single column frictional system in the 3rd and 7th ts'ai recording in Yingzaofashi", Master Dissertation, Taiyuan university of technology, Taiyuan.
- Wang, J., He, J., Yang, N. and Yang, Q. (2017), "Study on aseismic characteristics of Tibetan ancient timber structure", Adv. Mater. Sci. Eng., 3(16), 1-15. https://doi.org/10.1155/2017/8186768.
- Wang, J., He, J.X., Yang, Q.S. and Yang, N. (2018), "Study on mechanical behaviors of column foot joint in traditional timber structure", Struct. Eng. Mech., 66(1), 1-14. http://dx.doi.org/10.12989/sem.2018.66.1.001.
- Xia, H.L. (2015), "Experimental study on seismic behavior od through-tenon joints under different degree of looseness in ancient wooden buildings", Master Dissertation, Xian: Xian University of Architecture and Technology.
- Xie, Q.F., Zheng P.J. and Xiang W. (2018), "Experimental study on seismic behavior of damaged straight mortise-tenon joints of ancient timber buildings", J. Build. Struct., 35(11), 143-150.
- Xie, Q.F., Zheng, P.J., Cui, Y.Z., Qian, C.Y. and Zhang, F.L. (2015), "Experimental study on seismic behavior of straight mortise-tenon joints of ancient timber buildings", Earthq. Eng. Eng. Dyn., 35(3), 232-241.
- Xue, J.Y., Qi, L.J., Yang, K.Y. and Wu, Z.J. (2017) "Dynamic experimental study on single and double beam-column joints in steel traditional-style building", Struct. Eng. Mech., 63(5), 617-628. http://dx.doi.org/10.12989/sem.2017.63.5.617.
- Zhang, L. (2017), "Experimental study on the mechanical properties of wood and the numerical modeling strategies of wood", Master Dissertation, Beijing Jiaotong university, Beijing.
- Zhang, X.C., Xue, J.Y. and Zhao, H.T. (2011), "Study on Chinese ancient timber-frame building by shaking table test", Struct. Eng. Mech., 40(4), 453-469. http://dx.doi.org/10.12989/sem.2011.40.4.453.