A review on development in design of multistage centrifugal pump

  • Rode, Bhushan R. (Department of Civil Engineering, Maulana Azad National Institute of Technology) ;
  • Khare, Ruchi (Department of Civil Engineering, Maulana Azad National Institute of Technology)
  • 투고 : 2020.02.20
  • 심사 : 2020.09.01
  • 발행 : 2021.01.25

초록

Multi-stage pumps are the most popular pumps among various kinds of centrifugal pumps. Athorough review of different kinds of literature has led to the conclusion that there is a desperate need to increase the performance of the multi-stage centrifugal pump. Many investigators have put their efforts to increase the pump performance and also the work is being projected on various aspects of pump performance variables. To improve the multistage centrifugal pump performance by investigation, modification, and analysis many works of literature are available. For analysis, many researchers used the Navier-Stokes solver to create the three-dimensional unsteady turbulent flow numerical model with the standard k-ε turbulent equation. This paper mainly focuses on research related to the multi-stage centrifugal pump.

키워드

참고문헌

  1. Bai, Y., Kong, F., Xia, B. and Liu, Y. (2017), "Effect of blade number matching of impeller and diffuser in high-speed rescue pump", Advan. Mech. Eng., 9(5), 1687814017703595. https://doi.org/10.1177/1687814017703595.
  2. Chhanya, V.G. (2015), "Design and CFD analysis of submersible pump impeller of mixed flow type for performance improvement", Int. J. Advan. Eng. Res. Developm., 2(6), 468-475.
  3. Della Gatta, S., Salvadori, S., Adami, P. and Bertolazzi, L. (2006), "CFD study for assessment of axial thrust balance in centrifugal multistage pumps", Proceedings of Conference on Modeling Fluid Flow CMFF, 6, 6-9.
  4. Gantar, M., Florjancic, D. and Sirok, B. (2002), "Hydraulic axial thrust in multistage pumps-origins and solutions", J. Fluids Eng., 124(2), 336-341. https://doi.org/10.1115/1.1454110.
  5. Guo, S. and Maruta, Y. (2005), "Experimental investigations on pressure fluctuations and vibration of the impeller in a centrifugal pump with vaned diffusers", JSME Int. J. Series B Fluids Therm. Eng., 48(1), 136-143. https://doi.org/10.1299/jsmeb.48.136.
  6. Huang, S., Islam, M.F. and Liu, P. (2006), "Numerical simulation of 3D turbulent flow through an entire stage in a multistage centrifugal pump", Int. J. Comput. Fluid Dyn., 20(5), 309-314. https://doi.org/10.1080/10618560600916981.
  7. Kawashima, D., Kanemoto, T., Sakoda, K., Wada, A. and Hara, T. (2008), "Matching diffuser vane with return vane installed in multistage centrifugal pump", Int. J. Fluid Machinery Syst., 1(1), 86-91. https://doi.org/10.5293/IJFMS.2008.1.1.086.
  8. Kim, D.S., Mamatov, S., Jeon, S.G. and Park, W.G. (2017), "A study of the performance of a radial diffuser for a multistage high-pressure pump", J. Mech. Sci. Technol., 31(4), 1693-1700. https://doi.org/10.1007/s12206-017-0317-8.
  9. Lal, J. (2005), "Hydraulic Machines", Metropolitan Book Co Pvt. Ltd., New Delhi, India.
  10. Lugovaya, S., Olshtynsky, P., Rudenco, A. and Tverdokhleb, I. (2012), "Revisited designing of intermediate stage guide vane of centrifugal pump", Procedia Engineering, 39, 223-230. https://doi.org/10.1016/j.proeng.2012.07.028.
  11. Marathe, S.P., Saxena, M.R.R. and Solanki, M.C.H. (2013), "Numerical analysis on the performance characteristics of the centrifugal pump", Int. J. Eng. Res. Appl. (IJERA), 3(3), 1466-1469.
  12. Miyano, M., Kanemoto, T., Kawashima, D., Wada, A., Hara, T. and Sakoda, K. (2008), "Return vane installed in multistage centrifugal pump", Int. J. Fluid Machinery Syst., 1(1), 57-63. https://doi.org/10.5293/IJFMS.2008.1.1.057.
  13. Nagahara, T., Inoue, Y., Sato, T., Sakata, S., Nishimura, K. and Kato, C. (2005), "Investigation of the flow field in a multistage pump by using LES", Fluids Eng. Div. Summer Meeting, 41987, 1321-1329. https://doi.org/10.1115/FEDSM2005-77319.
  14. Naveema, M. and Suresh, P. (2013), "Lateral critical speed analysis of multistage centrifugal pump rotor using FEA", Int. J. Innovative Res. Sc. Eng. Technol., 2(8), 3914-3920.
  15. Rajendran, S. and Purushothaman, D.K. (2012), "Analysis of a centrifugal pump impeller using ANSYSCFX", Int. J. Eng. Res.Technol. (IJERT), 1(3), 2278-0181.
  16. Rakibuzzaman, R., Suh, S.H., Kim, K.W., Kim, H.H., Cho, M.T. and Yoon, I.S. (2015), "A study on multistage centrifugal pump performance characteristics for variable speed drive system", Procedia Engineering, 105, 270-275. https://doi.org/10.1016/j.proeng.2015.05.109.
  17. Roche-Carrier, L., Dituba Ngoma, G. and Ghie, W. (2013), "Numerical Investigation of a first stage of a multistage centrifugal pump: Impeller, diffuser with return vanes, and casing", ISRN Mech. Eng., 2013. https://doi.org/10.1155/2013/578072.
  18. Roclawski, H. and Hellmann, D.H. (2006), "Numerical simulation of a radial multistage centrifugal pump", In the 44th AIAA Aerospace Sciences Meeting and Exhibit, 1428. https://doi.org/10.2514/6.2006-1428.
  19. Shi, F. and Tsukamoto, H. (2001), "Numerical study of pressure fluctuations caused by impeller-diffuser interaction in a diffuser pump stage", J. Fluids Eng., 123(3), 466-474. https://doi.org/10.1115/1.1385835.
  20. Tan, M.G., He, X. H., Liu, H.L., Dong, L. and Wu, X.F. (2016), "Design and analysis of a radial diffuser in a single-stage centrifugal pump", Eng. Appl. Comput. Fluid Mech., 10(1), 500-511. https://doi.org/10.1080/19942060.2016.1210027.
  21. Tverdokhleb, I., Knyazeva, E., Birukov, A. and Lugovaya, S. (2012), "About designing the flow part of a multi-stage pump with a minimum radial dimensions", Procedia Engineering, 39, 84-90. https://doi.org/10.1016/j.proeng.2012.07.011.
  22. Wang, L., Liu, H., Wang, K., Zhou, L., Jiang, X. and Li, Y. (2019), "Numerical simulation of the sound field of a five-stage centrifugal pump with different turbulence models", Water, 11(9), 1777. https://doi.org/10.3390/w11091777.
  23. Wang, Z.J., Zheng, J.S., Li, L.L. and Luo, S. (2013), "Research on three-dimensional unsteady turbulent flow in multistage centrifugal pump and performance prediction based on CFD", Mathem. Prob. Eng., 2013. https://doi.org/10.1155/2013/589161.
  24. Zhang, L., Huang, P.J., Li, H.P. and Diao, Y.P. (2015), "CFD analysis of impeller internal flow field in multistage pump with inducer", Advan. Mater. Res., 1070, 1937-1940. https://doi.org/10.4028/www.scientific.net/AMR.1070-1072.1937.