DOI QR코드

DOI QR Code

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Received : 2020.07.08
  • Accepted : 2021.01.04
  • Published : 2021.01.25

Abstract

According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

Keywords

References

  1. ACI (American Concrete Institute) (2013), ACI 224.3R-95: "Joints in concrete construction", American Concrete Institute, Farmington Hills, MI, U.S.A.
  2. ACI Committee 318 (2008), "Building code requirement for structural concrete", American Concrete Institute.
  3. Almusallam, T.H., Elsanadedy, H.M. and Al-Salloum, Y.A. (2018), "Experimental investigation on vulnerability of precast RC beam-column joints to progressive collapse", KSCE J. Civil Eng., 22, 3995-4010. https://doi.org/10.1007/s12205-018-1518-0.
  4. Barbhuiya, S. and Choudhury, A.M. (2015), "A study on the size effect of RC beam-column connections under cyclic loading", Eng. Struct., 95, 1-7. https://doi.org/10.1016/j.engstruct.2015.03.052.
  5. Cheok, G.S. and Lew, H.S. (2017), "Model precast concrete beamto-column connections subjected to cyclic loading", PCI J., 38, 80-92. https://doi.org/10.15554/pcij.07011993.80.92
  6. Eurocode 2 (2004), "Design of concrete structures - Part 1-1: General rules and rules for buildings", EN 1992-1, CEN European Committee for Standardization, Brussels.
  7. Eurocode 8 (2004), "Design of structures for earthquake resistance -part 1: General rules, seismic actions and rules for buildings", EN 1998-1, CEN European Committee for Standardization, Brussels.
  8. French, C.W., Amu, O. and Tarzikhan, C. (1989), "Connection between precast elements - failure outside connection region", J. Struct. Eng., 115, 316-340. https://doi.org/10.1061/(ASCE)0733-9445(1989)115:2(316)
  9. Gerges, N.N., Issa, C.A. and Fawaz, S. (2017), "The effect of construction joints on the flexural bending capacity of singly reinforced beams", Case Studies Construct. Mater., 5, 122-123. https://doi.org/10.1016/j.cscm.2016.09.004.
  10. Ghobarah, A., Azi,z A. and Biddah, T.S. (1997), "Rehabilitation of reinforced concrete frame connections using corrugated steel jacketing", ACI Struct. J., 4(3), 283-294.
  11. Hadi, M. and Tran, T.M. (2016), "Seismic rehabilitation of reinforced concrete beam-column joints by bonding with concrete covers and wrapping with FRP composites", Mater. Struct., 49(1-2), 467-485. https://doi.org/10.1617/s11527-014-0511-4.
  12. Issa, C.A., Gerges, N.N. and Fawaz, S. (2014), "The effect of concrete vertical construction joints on modulus of rupture", Case Studies Construct. Mater., 1, 25-32. https://doi.org/10.1016/j.cscm.2013.12.001.
  13. IS 13920 (2016), Ductile detailing of reinforced concrete structures subjected to seismic forces- Code of Practice. Bureau of Indian Standard, New Delhi.
  14. IS 456 (2000), Plain and reinforced concrete - Code of Practice. Bureau of Indian Standard, New Delhi.
  15. IS 1608 (1995), Mechanical testing of metals - tensile testing, Bureau of Indian Standard, New Delhi.
  16. IS 432: Part 1 (1982), Specification for mild steel and medium tensile steel bars and hard-drawn steel wire for concrete reinforcement: Part I Mild steel and medium tensile steel bars, Bureau of Indian Standard, New Delhi.
  17. IS 10262 (2009), Guidelines for Concrete Mix Design Proportioning (CED 2: Cement and Concrete), Bureau of Indian Standard New Delhi, India.
  18. Joshi, M.K., Murty, C.V.R. and Jaisingh, M.P. (2005), "Cyclic behaviour of precast RC connections", Indian Concrete J., 79(11), 43-50.
  19. Kakaletsis, D.J., David, K.N. and Karayannis, C.G. (2011), "Effectiveness of some conventional seismic retrofitting techniques for bare and infilled R/C frame", Struct. Eng. Mech., 39(4), 499-520. https://doi.org/10.12989/sem.2011.39.4.499
  20. Karayannis, C.G. and Sirkelis, G.M. (2018), "Strengthening and rehabilitation of RC beam-column joints using C-FRP jacketing and epoxy resin injection", J. Earthq. Eng. Struct. Dyn., 18(37), 769-790. https://doi.org/10.1002/eqe.785.
  21. Karayannis, C.G, Chalioris, C.E. and Sirkelis, G.M. (2008), "Local retrofit of exterior RC beam-column joints using thin RC jackets-An experimental study", Earthq. Eng. Struct. Dyn., 37, 727-746. https://doi.org/10.1002/eqe.783
  22. Karayannis, C.G. and Golias, E. (2018), "Full scale tests of RC joints with minor to moderate seismic damage repaired using C-FRP sheets", Earthq. Struct., 15(6), 617-627. https://doi.org/10.12989/eas.2018.15.6.617.
  23. Lu, Z., Huang, J., Dai, S., Liu, J. and Zhang, M. (2019), "Experimental study on a precast beam-column joint with double grouted splice sleeves", Eng. Struct., 199, 109589. https://doi.org/10.1016/j.engstruct.2019.109589.
  24. Li, B., Kulkarni, S.A. and Leong, C.L. (2009), "Seismic performance of precast hybrid-steel concrete connections", J. Earthq. Eng., 13(5),667-689. https://doi.org/10.1080/13632460902837793.
  25. Marthong, C., Dutta, A. and Deb, S.K. (2016), "Effect of cyclic loading frequency on the behaviour of exterior RC beamcolumn joints", J. Earthq. Eng., 20(7), 1126-1147. https://doi.org/10.1080/13632469.2016.1138164.
  26. Marthong, C. (2019), "Rehabilitation of exterior RC beam-column connections using epoxy resin injection and FRP wrapping", Struct. Eng. Mech., 72(6), 723-736. https://doi.org/10.12989/eas.2019.16.3.253.
  27. Marthong, C. (2019), "Behavior of repaired RAC beam-column joints using steel welded wire mesh jacketed with cement mortar", Advan. Concrete Construct., 8(2), 91-100. https://doi.org/10.12989/acc.2019.8.2.091.
  28. Marthong, C. (2019), "Rehabilitation of exterior RC beam-column connections using epoxy resin injection and galvanized steel wire mesh", Earthq. Struct., 16(3), 253-263. https://doi.org/10.12989/eas.2019.16.3.253.
  29. Kataoka, M.N., Ferreira, M.A. and El Debs, A.L.H. (2015), "Study on the behavior of beam-column connection in precast concrete structure", Comput. Concrete, 16(1), 163-178. https://doi.org/10.12989/cac.2015.16.1.163.
  30. Naeim, F. and Kelly, J.M. (1999), Design of seismic isolated structures from theory to practice, John Willey & Sons, Inc.
  31. Parastesh, H., Hajirasouliha, I. and Ramezani, R. (2014), "A new ductile moment-resisting connection for precast concrete frames in seismic regions: An experimental investigation", Eng. Struct., 70, 144-157. https://doi.org/10.1016/j.engstruct.2014.04.001.
  32. Park, Y.J. and Ang, A.H.S. (1985), "Mechanistic seismic damage model for reinforced concrete", J. Struct. Eng., 111(4), 722-739. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:4(722)
  33. Roy, B. and Laskar, A.I. (2017), "Cyclic behaviour of in-situ exterior beam-column subassemblies with cold joint in column", Eng. Struc., 132, 822-833. https://doi.org/10.1016/j.engstruct.2016.12.001.
  34. Roy, B. and Laskar, A.I. (2018a), "Beam-column subassemblies with construction joint in columns above and below the beam", Mag. Concrete Res, 70(2), 71-83. https://doi.org/10.1680/jmacr.17.00155.
  35. Roy, B. and Laskar, A.I. (2018), "Roy cyclic performance of beam-column subassemblies with construction joint in column retrofitted with GFRP", Struct., 14, 290-300. https://doi.org/10.1016/j.istruc.2018.04.002.
  36. Rattapon, K. and Chayanon, H. (2016), "Seismic performance of interior precast concrete beam-column connections with Tsection steel inserts under cyclic loading", Earthq. Eng. Vib., 17, 355-369. https://doi.org/10.1007/s11803-018-0446-9.
  37. Shannag, M.J. and Alhassan, M.A. (2005), "Seismic upgrade of interior beam-column sub-assemblages with high performance fiber reinforced concrete jackets", ACI, Struct. J., 102(1), 131-138. https://doi.org/10.1007/s11803-018-0446-9.
  38. Tsonos, A.G. (2002), "Seismic repair of reinforced concrete beamcolumn subassemblages of modern structures by epoxy injection technique", J. Struct. Eng. Mech., 14(5), 543-563. http://dx.doi.org/10.12989/sem.2002.14.5.543
  39. Tsonos, A.G. (2014), "An innovative solution for strengthening of old R/C structures and for improving the FRP strengthening method", J. Struct. Monit. Maint. 1(3), http://dx.doi.org/10.12989/smm.2014.1.3.323
  40. Vidjeapriya, R. and Jaya, K.P. (2013), "Experimental study on two simple mechanical precast beam-column connections under reverse cyclic loading", J. Perform. Construct. Facilities, 27, 402-414. https://doi.org/10.1061/(ASCE)CF.1943-5509.0000324
  41. Xue, W. and Yang, X. (2010), "Seismic test of precast concrete moment resisting frames and connections", PCI J., 55, 102-121. https://doi.org/10.15554/pcij.06012010.102.121
  42. William, M.S. and Sexsmith, R.G. (1995), "Seismic damage indices for concrete structures: a state-of-the-art review", Earthq. Spectra, 11(2), 319-349. https://doi.org/10.1193/1.1585817