DOI QR코드

DOI QR Code

Analysis of hysteresis rule of energy-saving block and invisible multi-ribbed frame composite wall

  • Lin, Qiang (Shool of Civil Engineering, Huaqiao University) ;
  • Li, Sheng-cai (Shool of Civil Engineering, Huaqiao University) ;
  • Zhu, Yongfu (Minnan University of Science and Technology, Fujian Engineering Research Center for Construction and Management of Green Buildings)
  • Received : 2020.02.18
  • Accepted : 2020.09.29
  • Published : 2021.01.25

Abstract

The energy-saving block and invisible multi-ribbed frame composite wall (EBIMFCW) is a new type of load-bearing wall. The study of this paper focus on it is hysteresis rule under horizontal cyclic loading. Firstly, based on the experimental data of the twelve specimens under horizontal cyclic loading, the influence of two important parameters of axial compression ratio and shear-span ratio on the restoring force model was analyzed. Secondly, a tetra-linear restoring force model considering four feature points and the degradation law of unloading stiffness was established by combining theoretical analysis and regression analysis of experimental data, and the theoretical formula of the peak load of the EBIMFCW was derived. Finally, the hysteretic path of the restoring force model was determined by analyzing the hysteresis characteristics of the typical hysteresis loop. The results show that the curves calculated by the tetra-linear restoring force model in this paper agree well with the experimental curves, especially the calculated values of the peak load of the wall are very close to the experimental values, which can provide a reference for the elastic-plastic analysis of the EBIMFCW.

Keywords

Acknowledgement

The authors are very grateful to the National Natural Science Foundation of China (No. 51578253), the Scientific and Technological Planning Guiding Project of Fujian Province (2020Y0087), the Scientific and Technological Planning Project of Quanzhou City (No. 2018C083R), and the Subsidized Project for Postgraduates' Innovative Fund in Scientific Research of Huaqiao University (No. 18011086004) for the financial support of this work.

References

  1. Abdalla, J.A. and Hawileh, R.A. (2013), "Artificial Neural Network Predictions of Fatigue Life of Steel Bars Based on Hysteretic Energy", J. Comput. Civil Eng., 27(5), 489-496. https://doi.org/10.1061/(ASCE)CP.1943-5487.0000185.
  2. Borri, A., Castori, G. and Grazini, A. (2009), "Retrofitting of masonry building with reinforced masonry ring-beam", Construct. Build. Mater., 23, 1892-1901. https://doi.org/10.1016/j.conbuildmat.2008.09.012.
  3. Bhattacharya, S., Nayak, S. and Dutta, S.C. (2014), "A critical review of retrofitting methods for unreinforced masonry structures", J. Disaster Risk Reduction, 7, 51-67. http://dx.doi.org/10.1016/j.ijdrr.2013.12.004.
  4. Bolhassani, M., Hamid, A.A., Johnson, C. and Schultz, A.E. (2016), "Shear strength expression for partially grouted masonry walls", Eng. Struct., 127, 475-494. http://dx.doi.org/10.1016/j.engstruct.2016.09.001.
  5. Bolhassani, M., Hamid, A.A. and Moon, F.L. (2016), "Enhancement of lateral in-plane capacity of partially grouted concrete masonry shear walls", Eng. Struct., 108, 59-76. http://dx.doi.org/10.1016/j.engstruct.2015.11.017.
  6. Chen, Z.P., Xu, J.J., Chen, Y.L., Su, Y.S. (2016), "Seismic behavior of T-shaped steel reinforced high strength concrete short-limb shear walls under low cyclic reversed loading", Structural Engineering and Mechanics, 57(4), 681-701. https://doi.org/10.12989/sem.2016.57.4.681.
  7. ElDin, H.M., Ashour, A. and Galal, K. (2019), "Seismic performance parameters of fully grouted reinforced masonry squat shear walls", Eng. Struct., 187, 518-527. https://doi.org/10.1016/j.engstruct.2019.02.069.
  8. GB50003-2011, Code for design of masonry structures, China Architecture and Building Press; Beijing, China.
  9. Martinez, M. and Atamturktur, S. (2019), "Experimental and numerical evaluation of reinforced dry-stacked concrete masonry walls", J. Build. Eng., 22, 181-191. https://doi.org/10.1016/j.jobe.2018.12.007.
  10. Marques R. and B. Lourenco P. (2019), "Structural behaviour and design rules of confined masonry walls: Review and proposals", Construct. Build. Mater., 217, 137-155. https://doi.org/10.1016/j.conbuildmat.2019.04.266.
  11. Nayak, S. and Dutta, S.C. (2016), "Failure of masonry structures in earthquake: A few simple cost effective techniques as possible solutions", Eng. Struct., 106, 53-67. http://dx.doi.org/10.1016/j.engstruct.2015.10.014.
  12. Parulekar, Y.M., Reddy, G.R., Singh, R.K., Gopalkrishnan, N., Ramarao, G.V. (2016), "Seismic performance evaluation of mid-rise shear walls: experiments and analysis", Struct. Eng. Mech., 59(2), 291-312. https://doi.org/10.12989/sem.2016.59.2.291.
  13. Roy, S., Khan, M.S.R. and Ahmad, S.I. (2013), "Comparative Cost Analysis of Possible Seismic Retrofitting Schemes for Multi-Story Unreinforced Masonry Building", Procedia Eng., 54, 584-590. https://doi.org/10.1016/j.proeng.2013.03.053.
  14. Su, Q.W., Zhao, S.C. and Ye, L.P. (2015), "Research on seismic evaluation of masonry structures", J. Build. Struct., 35(1), 111-116. https://doi.org/10.14006/j.jzjgxb.2014.01.015.
  15. Sisti, R., Corradi, M. and Borri A. (2016), "An experimental study on the influence of composite materials used to reinforce masonry ring beams", Construct. Build. Mater., 122, 231-241. http://dx.doi.org/10.1016/j.conbuildmat.2016.06.120.
  16. S. Dhomane P., B. Katpelwar S. and M. Chavhan A. (2017), "Overview of Seismic Retrofitting Building", IARJSET, 4(3), 11-13. https://doi.org/10.17148/IARJSET.
  17. Saqan, E.I., Rasheed, H.A.A. and Alkhrdaji, T. (2018), "Evaluation of the seismic performance of reinforced concrete frames strengthened with CFRP fabric and NSM bars", Compos. Struct., 184, 839-847. http://dx.doi.org/10.1016/j.compstruct.2017.10.069.
  18. Sayin, B., Yildizlar, B., Akcay, C. and Gunes, B. (2019), "The retrofitting of historical masonry buildings with insufficient seismic resistance using conventional and non-conventional techniques", Eng. Failure Anal., 97, 454-463. https://doi.org/10.1016/j.engfailanal.2019.01.031.
  19. Tran, CTN. and Li, B. (2018), "Seismic performance of RC short columns with light transverse reinforcement", Struct. Eng. Mech., 67(1), 93-104. https://doi.org/10.12989/sem.2018.67.1.093.
  20. Voon, K.C. and Ingham, J.M. (2006), "Experimental in-plane shear strength investigation of reinforced concrete masonry walls", Eng. Struct., 132(3), 400-408. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:3(400).
  21. Zheng, N.N., Li, Y.M. and Pan, Y. (2011), "Seismic Behavior of Low Masonry Structure with Core-Tie-Columns", J. Southwest Jiatong U., 46(1), 24-30. https://doi.org/10.3969/j.issn.0258-2724.2011.01.004.
  22. Zheng, N.N., Li, Y.M. and Liu F.Q. (2013), "Pseudo-static test study on seismic behavior of masonry wall restrained by core-tie-columns", China Civil Eng. J., 46(s1), 202-207. https://doi.org/10.15951/j.tmgcxb.2013.s1.047.
  23. Zhao, J. and Dun, H.H. (2014), "A restoring force model for steel fiber reinforced concrete shear walls", Eng. Struct., 75, 469-476. http://dx.doi.org/10.1016/j.engstruct.2014.06.013.