DOI QR코드

DOI QR Code

기존 벽식 철근 콘크리트조 대비 프리캐스트 콘크리트조 공동주택 외피의 단열성능 비교분석

Insulation Performance Comparison of Apartment Building Envelopes Composed of Reinforced Concrete and Precast Concrete

  • 주나영 (이화여자대학교 대학원) ;
  • 송승영 (이화여자대학교 대학원)
  • 투고 : 2021.10.13
  • 심사 : 2021.11.26
  • 발행 : 2021.12.30

초록

The aim of this study is to evaluate the actual insulation performance of the apartment building PC (precast concrete) envelope to which steel tying materials are additionally installed between structures and hollow-core slabs are applied. Through three-dimensional steady-state heat transfer simulation, the energy performance and condensation risk of each envelope composed of RC (reinforced concrete) and PC having the same legal U-factor and insulation method were compared and analyzed. As results, it was found that the effective U-factor and temperature difference ratio of the RC and PC envelopes were very similar, indicating that the energy performance and condensation risk were almost the same. The effective U-factor of both the RC and PC envelopes was about 30 to 90% higher than the legal U-factor, indicating a large heat loss due to thermal bridges. Therefore, in order to improve energy performance, it is necessary to remove thermal bridges in both the RC and PC envelopes.

키워드

과제정보

본 연구는 국토교통부/국토교통과학기술진흥원의 지원으로 수행되었음.(과제번호 21ORPS-B158109-02)

참고문헌

  1. Choi, B. H., & Song, S. Y.(2021). Insulation Performance Comparison of Curtain Wall Systems with Existing Pipe Frames and Truss-Shaped Insulation Frames, Energies 2021, 14(15), 4682.
  2. ISO 10211 : 2017, Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculation.
  3. ISO 10077-2 : 2017, Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2 : Numerical method for frames.
  4. ISO 13789 : 2017, Thermal performance of buildings - Transmission and ventilation heat transfer coefficients - Calculation method.
  5. KIAEBS S-11 : 2020, Calculation of Temperature Difference Ratio for Evaluation of Condensation Prevention performance in Apartment Buildings-Analysis Method.
  6. KIAEBS S-13 : 2020, Calculation method of thermal performance of thermal bridge vreaker applied to thermal bridge in building envelope.
  7. Korea Energy Agency(2018). Energy Saving Design Standards of Buildings.
  8. Korea Energy Agency(2020). Commentary of Energy Saving Design Standards of Buildings.
  9. Lee, S. H., Baik, H.., Baik, Y. S., Choi, J. H., & Jeong, M. Y.(2015). Development and Performance Evaluation of Exterior Insulation Precast Concrete Wall forCommercialization, Journal of the architectural Institute of Korea Planning & Design, 31(9), 2015.09, 129-136(8 pages). https://doi.org/10.5659/JAIK_PD.2015.31.9.129
  10. Mahardhikal, R. V., Defiana, I., & Noerwasito, R. k.(2014). Thermal Performance of Apartment(High-Rise) in Surabaya with Precast Concrete for the building Envelope, IPTEK, Journal of Preceeding Series, Vol 1.
  11. Ministry of Land, Infrastructure and Transport(MLIT) (2014) Detailed guidlines for Preventing Condensation in Apartment Buildings.
  12. Ministry of Land, Infrastructure and Transport(MLIT) (2016) Design Standard for Preventing Condensation in Apartment Buildings.
  13. Ministry of Land, Infrastructure and Transport(MLIT) (2020). Construction Standard of Energy Saving Environmental Friendly House.
  14. O'Hegarty, R., Clifford R. W. M., Grimes, M., Kinnane, O., & Newell, J.(2021). Development of thin precast concete sandwich panels: Challenges and outcomes, Construction and Building Material, Volume 267.
  15. Park, H. G., Hong, G. H., Kim, S. H., & Park, S. G.(2011). Development of a residential PC prefabricated building structure system, Korea Journal of Construction engineering and management 12(1), 11-16.