DOI QR코드

DOI QR Code

Optimal Design of Semi-Active Mid-Story Isolation System using Supervised Learning and Reinforcement Learning

지도학습과 강화학습을 이용한 준능동 중간층면진시스템의 최적설계

  • Received : 2021.10.26
  • Accepted : 2021.11.03
  • Published : 2021.12.15

Abstract

A mid-story isolation system was proposed for seismic response reduction of high-rise buildings and presented good control performance. Control performance of a mid-story isolation system was enhanced by introducing semi-active control devices into isolation systems. Seismic response reduction capacity of a semi-active mid-story isolation system mainly depends on effect of control algorithm. AI(Artificial Intelligence)-based control algorithm was developed for control of a semi-active mid-story isolation system in this study. For this research, an practical structure of Shiodome Sumitomo building in Japan which has a mid-story isolation system was used as an example structure. An MR (magnetorheological) damper was used to make a semi-active mid-story isolation system in example model. In numerical simulation, seismic response prediction model was generated by one of supervised learning model, i.e. an RNN (Recurrent Neural Network). Deep Q-network (DQN) out of reinforcement learning algorithms was employed to develop control algorithm The numerical simulation results presented that the DQN algorithm can effectively control a semi-active mid-story isolation system resulting in successful reduction of seismic responses.

Keywords

Acknowledgement

본 논문은 2019년도 정부(과학기술정보통신부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임. (No. NRF-2019R1A2C1002385).

References

  1. Naeim, F. and Kelly, J.M., Design of Seismic Isolated Structures: from Theory to Practice. Wuley: New York. 1999.
  2. Kelly, J.M., "The current state of base isolation in the Unite States", Proc. Second World Conference on Structural Control, Kyoto, Japan, 1999, pp.1043-1052.
  3. Hur, M. W., "Construction of Isolation Device for DONG-IL High-Vill New City", Review of Architecture and Building Science, Vol. 54, No. 5, pp.81-86, 2010.
  4. Tsuneki, Y., Torii, S., Murakami, K. and Sueoka, T., "Middle-Story Isolated Structural System of High-Rise Building", Proceeding of The 14th World Conference on Earthquake Engineering, 2008.
  5. Mele, E. and Faiella, D., "Inter-story isolation systems (IIS) for tall buildings: design considerations", Structural Engineering, CTBUH Journal, Issue 2, pp. 34-41, 2018.
  6. Chey, M.H., Chase, J.G., Mander, J.B. and Carr, A.J., "Semi-active control of mid-story isolation building system", AKC 2009, Asia Korean Conference on Advanced Science & Technology, 2009.
  7. Kim, H.S. and Kang, J.W., "Simultaneous multi-objective optimization of semi-active intermediate isolation system and building structures", International Journal of Steel Structures, Vol. 21, pp. 604-612, 2021. https://doi.org/10.1007/s13296-021-00459-0
  8. Symans, M.D. and Constantinou, M.C., "Semi-active control systems for seismic protection of structures: a state-of-the-art review", Engineering Structures, Vol. 21, pp. 469-487, 1999. https://doi.org/10.1016/S0141-0296(97)00225-3
  9. Koo, J.H., "Using magneto-rheological dampers in semiactive tuned vibration absorbers to control structural vibrations", Ph.D. Dissertation, Virginia Polytechnic Institute and State University, USA, 2003.
  10. Yoshioka, H., Ramallo, J.C. and Spencer Jr., B.F., "Smart base isolation strategies employing magnetorheological dampers", Journal of Engineering Mechanics, Vol. 128, pp. 540-551, 2002. https://doi.org/10.1061/(asce)0733-9399(2002)128:5(540)
  11. Kim, H.S. and Kang, J.W., "Vibration control performance evaluation of hybrid mid-story isolation system for a tall building", Journal of Korean Association for Spatial Structures, Vol. 18, No. 3 pp. 37-44, 2018. https://doi.org/10.9712/KASS.2018.18.3.37
  12. Bathaei, A., Zahrai, S.M. and Ramezani, M., "Semi-active seismic control of an 11-DOF building model with TMD+MR damper using type-1 and -2 fuzzy algorithms", Journal of Vibration and Control, Vol. 24, No. 13, pp. 2938-2953, 2018. https://doi.org/10.1177/1077546317696369
  13. Raffaele, C., Marta, T., Giuseppina, P., Antonella, P. and Fabio, D.F., "Artificial Intelligence and Machine Learning Applications in Smart Production: Progress, Trends, and Directions", Sustainability, Vol. 12, No. 2, 2020.
  14. Wei, T., Wang, Y. and Zhu, Q., "Deep reinforcement learning for building HVAC control", 54th ACM/EDAC/IEEE Design Automation Conference (DAC), pp. 1-6, 2017.
  15. Sueoka, T., Torii, S. and Tsuneki, Y., "The Application of Response Control Design using Middle-Story Isolation System to High-Rise Builsing", The 13th World Conference on Earthquake Engineering, 2004.
  16. Kim, H.S. and Kang, J.W., "Vibration control performance evaluation of hybrid mid-story isolation system for a tall building", Journal of the Korean Association for Spacial Structures, Vol. 18, No. 3, pp. 37-44, 2018. https://doi.org/10.9712/KASS.2018.18.3.37
  17. Sues, R. H., Mau, S. T. and Wen, Y. K., "System identifcation of degrading hysteretic restoring forces", Journal of Engineering Mechanics, ASCE, Vol. 114, pp. 833-846, 1988. https://doi.org/10.1061/(ASCE)0733-9399(1988)114:5(833)
  18. Kim, H.S. and Parkg, K.S., "Research on hyperparameter of RNN for seismic response prediction of a structure with vibration control system)", Journal of the Korean Association for Spacial Structures, Vol. 20, pp. 51-58, 2020. https://doi.org/10.9712/KASS.2020.20.2.51
  19. Nagarajaiah, S. and Narasimhan, S., "Smart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systems", Journal of Structural Control and Health Monitoring, Vol. 12, pp. 589-604, 2006. https://doi.org/10.1002/stc.100
  20. Volodymyr, M., Koray, K., David, S., Andrei, A.R., Joel, V., Marc, G.B., Alex, G., Martin, R., Andreas, K.F., Georg, O., Stig, P., Charles, B., Amir, S., Ioannis, A., Helen, K., Dharshan, K., Daan, W., Shane, L. and Demis, H., "Human-level control through deep reinforcement learning", Nature, Vol. 518, pp. 529-533, 2015. https://doi.org/10.1038/nature14236