The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy

저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향

  • Park, Young-Sang (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) ;
  • Son, ByeongJin (Daegu Catholic University) ;
  • Son, Jaebum (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) ;
  • Lee, Hoyul (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) ;
  • Jeong, Yoosoo (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) ;
  • Song, Chanho (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) ;
  • Jung, Euisung (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation)
  • 박영상 ((재)대구경북첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 손병진 (대구가톨릭대학교) ;
  • 손재범 ((재)대구경북첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 이호열 ((재)대구경북첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 정유수 ((재)대구경북첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 송찬호 ((재)대구경북첨단의료산업진흥재단 첨단의료기기개발지원센터) ;
  • 정의성 ((재)대구경북첨단의료산업진흥재단 첨단의료기기개발지원센터)
  • Received : 2021.10.11
  • Accepted : 2021.12.22
  • Published : 2021.12.31

Abstract

Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

Keywords

Acknowledgement

본 연구는 산업통상자원부와 한국산업기술진흥원의 "스마트특성화 기반구축사업(P0017662 고기능인체결합 의료기기 산업육성 플랫폼 구축사업)"의 지원을 받아 수행된 연구결과임.

References

  1. Park YS, Kwon O, Cho HS, Son J. U-Healthcare Patch Type Wireless Body Temperature Monitoring System. Journal of Biomedical Engineering Research. 2020;41(1):55-61. https://doi.org/10.9718/JBER.2020.41.1.55
  2. Islam SR, Kwak D, Kabir MH, Hossain M, Kwak KS. The internet of things for health care: a comprehensive survey. IEEE access 3, 2015;678-708. https://doi.org/10.1109/ACCESS.2015.2437951
  3. Pang Z. Technologies and Architectures of the Internet-of-Things (IoT) for Health and Well-being (Doctoral dissertation, KTH Royal Institute of Technology). 2013.
  4. Polonelli T, Brunelli D, Girolami A, Demmi GN, Benini L. A multi-protocol system for configurable data streaming on IoT healthcare devices. 2019 IEEE 8th International Workshop on Advances in Sensors and Interfaces (IWASI). 2019; pp. 112-117.
  5. Lee HJ, Lee SH, Ha KS, Jang HC, Chung WY, Kim JY, Yoo DH. Ubiquitous healthcare service using Zigbee and mobile phone for elderly patients. International journal of medical informatics. 2009;78(3):193-198. https://doi.org/10.1016/j.ijmedinf.2008.07.005
  6. Lee JS, Su YW, Shen CC. A comparative study of wireless protocols: Bluetooth, UWB, ZigBee, and Wi-Fi. In IECON 2007-33rd Annual Conference of the IEEE Industrial Electronics Society. 2007;pp. 46-51.
  7. Khriji S, El Houssaini D, Kammoun I, Kanoun O. Precision Irrigation: An IoT-Enabled Wireless Sensor Network for Smart Irrigation Systems. In Women in Precision Agriculture. Springer, Cham. 2021;107-129.
  8. Baek HJ, Cho J. Development of a Ring-type Wearable Healthcare Device. The Transactions of The Korean Institute of Electrical Engineers. 2018;67(7):892-897. https://doi.org/10.5370/KIEE.2018.67.7.892
  9. Lin ZM, Chang CH, Chou NK, Lin YH. Bluetooth Low Energy (BLE) based blood pressure monitoring system. In 2014 International Conference on Intelligent Green Building and Smart Grid (IGBSG). 2014;1-4.
  10. GLS_SPEC_V10. Bluetooth SIG. 2012. pp. 9
  11. HRS_SPEC_V10. Bluetooth SIG. 2011. pp. 9
  12. HTS_SPEC_V10. Bluetooth SIG. 2011. pp. 9
  13. 의료기기 품목 및 품목별 등급에 관한 규정. 식품의약품안전처고시 제2021-24호: 식품의약품안전처; 2021.
  14. 의료기기 기준규격. 식품의약품안전처고시 제2021-3호: 식품의약품안전처; 2021.
  15. 무선심전계시스템 동등제품공고. 식품의약품안전처; 2017.
  16. Gomez C, Oller J, Paradells J. Overview and evaluation of bluetooth low energy: An emerging low-power wireless technology. Sensors. 2012;12(9):11734-11753. https://doi.org/10.3390/s120911734
  17. 무선 설비적합성평가시험방법. 방송통신표준심의회; 2020.
  18. Kim G. A Study of BLE Mesh Network Scheduling Algorithm Using A Smartplug. Turkish Journal of Computer and Mathematics Education (TURCOMAT). 2021;12(6):456-451.
  19. 유헬스케어 의료기기 시스템 허가심사 가이드라인. 식품의약품안전처; 2016.
  20. 유헬스케어 의료기기 품목별 허가심사 가이드라인. 식품의약품안전처; 2016.