과제정보
This research was supported by the National Natural Science Foundation of China under Grant 51767001.
참고문헌
- Chen, C., Du, W.J., Wang, H.F., Littler, T.: Sub-synchronous oscillations in power systems caused by grid-connected wind farms-a survey of mechanism studies. CSEE J. Power Energy Syst. 4(4), 495-503 (2018) https://doi.org/10.17775/CSEEJPES.2018.00560
- IEEE Subsynchronous Resonance Working Group: Terms, definitions and symbols for subsynchronous oscillations. IEEE Trans. Power Appar. Syst. PAS-104(6), 1326-1334 (1985) https://doi.org/10.1109/TPAS.1985.319152
- Li, P.H., Xiong, L.Y., Wang, J., Ma, M.L., Khan, M.W.: SSCI mitigation of series-compensated DFIG wind power plants with robust sliding mode controller using feedback linearization. J. Power Electron. 19(2), 569-579 (2019) https://doi.org/10.6113/JPE.2019.19.2.569
- Liang, X.D.: Emerging power quality challenges due to integration of renewable energy sources. IEEE Trans. Ind. Appl. 53(2), 855-866 (2017) https://doi.org/10.1109/TIA.2016.2626253
- Mitra, A., Chatterjee, D.: Active power control of DFIG-based wind farm for improvement of transient stability of power systems. IEEE Trans. Power Syst. 31(1), 82-93 (2016) https://doi.org/10.1109/TPWRS.2015.2397974
- Wang, Y., Meng, J., Zhang, X., Lie, X.: Control of PMSG-based wind turbines for system inertial response and power oscillation damping. IEEE Trans. Sustain. Energy 6(2), 565-574 (2015) https://doi.org/10.1109/TSTE.2015.2394363
- Luo, H., Lin, M.Y., Cao, Y., Guo, W., Hao, L., Wang, P.: A calculation method for the nonlinear crowbar circuit of DFIG wind generation based on frequency domain analysis. J. Power Electron. 16(5), 1884-1893 (2016) https://doi.org/10.6113/JPE.2016.16.5.1884
- Zhao, H.Y., Zheng, T., Li, Y., Du, J.F., Shi, P.: Control and analysis of Vienna rectifier used as the generator-side converter of PMSG-based wind power generation system. J. Power Electron. 17(1), 212-221 (2017)
- Liu, H.K., Xie, X.R., He, J.B., Xu, T., Wang, C., Zhang, C.Y.: Subsynchronous interaction between direct-drive PMSG based wind farms and weak AC networks. IEEE Trans. Power Syst. 32(6), 4708-4720 (2017) https://doi.org/10.1109/TPWRS.2017.2682197
- Fan, L., Miao, Z.: Mitigating SSR using DFIG-based wind generation. IEEE Trans. Sustain. Energy 3(3), 349-358 (2012) https://doi.org/10.1109/TSTE.2012.2185962
- Song, Y.P., Blaabjerg, F.: Overview of DFIG-based wind power system resonances under weak networks. IEEE Trans. Power Electron. 32(6), 4370-4394 (2017) https://doi.org/10.1109/TPEL.2016.2601643
- Huang, P.-H., Moursi, M., Xiao, W.D., Kirtlry, J.: Subsynchronous resonance mitigation for series-compensated DFIG-based wind farm by using two-degree-of-freedom control strategy. IEEE Trans. Power Syst. 30(3), 1442-1454 (2015) https://doi.org/10.1109/TPWRS.2014.2348175
- Ren, W., Larsen, E.: A refined frequency scan approach to subsynchronous control interaction (SSCI) study of wind farms. IEEE Trans. Power Syst. 31(5), 3904-3912 (2016) https://doi.org/10.1109/TPWRS.2015.2501543
- Liu, H.K., Xie, X.R., Zhang, C.Y., Li, Y., Liu, H., Hu, Y.H.: Quantitative SSR analysis of series-compensated DFIG-based wind farms using aggregated RLC circuit model. IEEE Trans. Power Syst. 32(1), 474-483 (2017) https://doi.org/10.1109/TPWRS.2016.2558840
- Peng, Y.J., Li, Y., Liu, F., Xu, Z.W., Cao, Y.J.: Frequency stabilization method for grid integration of large-scale centralized wind farm via VSC-HVDC technology. J. Power Electron. 18(2), 547-557 (2018) https://doi.org/10.6113/JPE.2018.18.2.547
- Shair, J., Xie, X.R., Wang, L.P., Liu, W., He, J.B., Liu, H.: Overview of emerging subsynchronous oscillations in practical wind power systems. Renew. Sustain. Energy Rev. 32, 159-168 (2019)
- Miao, Z.X.: Impedance-model-based SSR analysis for type 3 wind generator and series-compensated network. IEEE Trans. Energy Convers. 27(4), 984-991 (2012) https://doi.org/10.1109/TEC.2012.2211019
- Fan, L., Kavasseri, R., Miao, Z.L., Zhu, C.X.: Modeling of DFIG-based wind farms for SSR analysis. IEEE Trans. Power Del. 25(4), 2073-2082 (2010) https://doi.org/10.1109/TPWRD.2010.2050912
- Xie, X.R., Zhang, X., Liu, H.K., Liu, H., Li, Y.H., Zhang, C.Y.: Characteristic analysis of subsynchronous resonance in practical wind farms connected to series-compensated transmissions. IEEE Trans. Energy Convers. 32(3), 1117-1126 (2017) https://doi.org/10.1109/TEC.2017.2676024
- Wen, B., Boroyevich, D., Burgos, R., Mattavwlli, P., Shen, Z.Y.: Analysis of D-Q small-signal impedance of grid-tied inverters. IEEE Trans. Power Electron. 31(1), 675-687 (2016) https://doi.org/10.1109/TPEL.2015.2398192
- Wang, X., Blaabjerg, F., Liserre, M., Chen, Z., He, J.W., Li, Y.W.: An active damper for stabilizing power-electronics-based AC system. IEEE Trans. Power Electron. 29(7), 3318-3329 (2014) https://doi.org/10.1109/TPEL.2013.2278716
- Liu, Z., Liu, J., Bao, W., Zhao, Y.: Infinity-norm of impedance-based stability criterion for three-phase AC distributed power systems with constant power loads. IEEE Trans. Power Electron. 30(6), 3030-3043 (2015) https://doi.org/10.1109/TPEL.2014.2331419
- Bi, T.S., Li, J.Y., Zhang, P., Mitchell-Colgan, E., Xiao, S.W.: Study on response characteristics of grid-side converter controller of PMSG to sub-synchronous frequency component. IET Renew. Power Gener. 11(7), 966-972 (2017) https://doi.org/10.1049/iet-rpg.2016.0994
- Chae, B., Suh, Y., Kang, T.: Three-phase three switch buck-type rectifier based on current source converter for 5 MW PMSG wind turbines systems. J. Power Electron. 18(5), 1501-1512 (2018) https://doi.org/10.6113/JPE.2018.18.5.1501
- Xu, Y.H., Cao, Y.P.: Sub-synchronous oscillation in PMSGs based wind farms caused by amplification effect of GSC controller and PLL to harmonics. IET Renew. Power Gener. 12(7), 844-850 (2018) https://doi.org/10.1049/iet-rpg.2017.0740