DOI QR코드

DOI QR Code

Seismic performance of high-strength steel framed-tube structures with bolted web-connected replaceable shear links

  • Lian, Ming (School of Civil Engineering, Xi'an University of Architecture & Technology) ;
  • Cheng, Qianqian (School of Civil Engineering, Xi'an University of Architecture & Technology) ;
  • Guan, Binlin (School of Civil Engineering, Xi'an University of Architecture & Technology) ;
  • Zhang, Hao (School of Civil Engineering, Xi'an University of Architecture & Technology) ;
  • Su, Mingzhou (School of Civil Engineering, Xi'an University of Architecture & Technology)
  • 투고 : 2020.04.04
  • 심사 : 2020.06.01
  • 발행 : 2020.11.10

초록

In steel framed-tube structures (SFTSs), the plastic hinges at beam-ends cannot be adequately improved because of the large cross sections of spandrel beams, which results in the lower ductility and energy dissipation capacities of traditional SFTSs. To address this drawback, high-strength steel fabricated SFTSs with bolted web-connected replaceable shear links (HSFTS-SLs) have been proposed. In this system, shear links use conventional steel and are placed in the middle of the deep spandrel beams to act as energy dissipative components. In this study, 2/3-scaled HSFTS-SL specimens were fabricated, and cyclic loading tests were carried out to study the seismic performance of both specimens. The finite element models (FEMs) of the two specimens were established and the numerical results were compared with the test results. The results showed that the specimens had good ductility and energy dissipation capacities due to the reliable deformation capacities. The specimens presented the expected failure modes. Using a shorter shear link can provide a higher load-carrying capacity and initial elastic lateral stiffness but induces lower ductility and energy dissipation capacity in HSFTS-SLs. The performance of the specimens was comparable to that of the original sub-structure specimens after replacing shear links. Additionally, the expected post-earthquake recoverability and resilience of the structures could be achieved by replacing shear links. The acceptable residual interstory drift that allows for easy replacement of the bolted web-connected shear link was 0.23%. The bolted web-connected shear links had reliable hysteretic responses and deformation capacities. The connection rotation had a notable contribution to total link rotation. The results of the numerical analysis run for the proposed FEMs were consistent with the test results. It showed that the proposed FEMs could be used to investigate the seismic performance of the HSFTS-SL.

키워드

과제정보

The authors are grateful for the partial financial support from the National Natural Science Foundation of China [Grant No. 51708444].

참고문헌

  1. AISC 358-16 (2016), Prequalified connections for special and intermediate steel moment frames for seismic applications; Chicago, USA.
  2. Alavi, A. and Rahgozar, R. (2018), "Optimal stiffness distribution in preliminary design of tubed-Ssystem Ttall buildings", Struct. Eng. Mech., 65(6), 731-739. https://doi.org/10.12989/sem.2018.65.6.731.
  3. Alavi, A., Rahgozar, P. and Rahgozar, R. (2018), "Minimum-weight design of high-rise structures subjected to flexural vibration at a desired natural frequency", Struct. Des. Tall Spec. Build. J., 27(15), e1515.1-e1515.11. DOI: 10.1002/tal.1515.
  4. ANSI/AISC 341-16 (2016). Seismic provision for structure steel buildings; Chicago, USA.
  5. Caprili, S., Mussini, N. and Salvatore, W. (2018). "Experimental and numerical assessment of EBF structures with shear links", Steel Compos. Struct., 28(2), 123-138. https://doi.org/10.12989/scs.2018.28.2.123.
  6. Chaboche, J. L. (1989). "Constitutive equations for cyclic plasticity and cyclic viscoplasticity", International Journal of Plasticity, 5(3), 247-302. DOI: 10.1016/0749-6419(89)90015-6.
  7. Dusicka, P., Itani, A.M. and Buckle, I.G. (2010), "Cyclic behavior of shear links of various grades of plate steel", J. Struct. Eng.,136(4), 370-378. DOI: 10.1061/(ASCE)ST.1943-541X.0000131.
  8. GB50011-2010 (2010), Code for seismic design of buildings; Beijing, China.
  9. GB50017-2017 (2017), Code for design of steel structures; Beijing, China.
  10. Ghobarah, A. (2001), "Performance-based design in earthquake engineering: state of development", Eng. Struct., 23(8), 878-884. DOI: 10.1016/S0141-0296(01)00036-0.
  11. JGJ 99-2015 (2015), Technical specification for steel structure of tall buildings; Beijing, China.
  12. JGJ 82-2011 (2011), Technical specification for high strength bolt connections of steel structures; Beijing, China.
  13. JGJ/T101-2015 (2015), Specification for seismic test of buildings; Beijing, China.
  14. Kamgar, R. and Rahgozar, R. (2015), "Determination of critical excitation in seismic analysis of structures", Earthq. Struct., 9(4), 875-891. https://doi.org/10.12989/eas.2015.9.4.875.
  15. Kamgar, R., Samea P. and Mohsen, K. (2017). "Optimizing parameters of tuned mass damper subjected to critical earthquake", Struct. Des. Tall Spec. Build., 27(10), e1460. DOI: 10.1002/tal.1460.
  16. Kamgar, R., Shojaee, S. and Rahgozar, R. (2015), "Rehabilitation of tall buildings by active control system subjected to critical seismic excitation", Asian J. Civil Eng., 16(6), 819-833.
  17. Kamgar, R. and Rahgozar, R. (2015), "Determination of optimum location for flexible outrigger systems in non-uniform tall buildings using energy method", Int. J. Optim. Civil Eng., 5(4), 433-444. DOI: 10.1109/ISAM.2009.5376959.
  18. Kamgar, R. and Rahgozar, R. (2017), "Determination of optimum location for flexible outrigger system in tall buildings with constant cross-section consisting of framed tube, shear core, belt truss and outrigger system using energy method", Int. J. Steel Struct., 17(1), 1-8. DOI: 10.1007/s13296-014-0172-8.
  19. Kamgar, R. and Rahgozar, P. (2019), "Reducing static roof displacement and axial forces of columns in tall buildings based on obtaining the best locations for multi-rigid belt truss outrigger systems", Asian J. Civil Eng., 20(6), 759-768. DOI: 10.1007/s42107-019-00142-0.
  20. Lian, M., Su, M. and Guo, Y. (2017), "Experimental performance of Y-shaped eccentrically braced frames fabricated with high strength steel", Steel Compos. Struct., 24(4), 441-453. https://doi.org/10.12989/scs.2017.24.4.441.
  21. Lian, M., Cheng, Q.Q., Zhang, H. and Su, M. Z. (2020), "Numerical study of the seismic behavior of steel frame-tube structures with bolted web-connected replaceable shear links", Steel Compos. Struct., 35(3), 305-325. https://doi.org/10.12989/scs.2020.35.3.305
  22. Malekinejad, M., Rahgozar, R., Malekinejad, A. and Rahgozar, P. (2016), "A continuous-discrete approach for evaluation of natural frequencies and mode shapes of high-rise buildings", Int. J. Adv. Struct. Eng., 8(3), 269-280. DOI: 10.1007/s40091-016-0129-6.
  23. Mansour, N., Christopoulos, C. and Tremblay, R. (2011). "Experimental validation of replaceable shear links for eccentrically braced steel frames", J. Struct. Eng., 137(10), 1141-1152. DOI: 10.1061/(ASCE)ST.1943-541X.0000350.
  24. McCormick, D., Aburano, H., Ikenaga, M. and Nakashima, M. (2008), "Permissible residual deformation level for building structures considering both safety and human elements", Procedings of the 14th World Conf. on Earthquake Engineering, Beijing.
  25. Moon, K.S. (2010), "Stiffness-based design methodology for steel braced tube structures: a sustainable approach", Steel Constr., 32(10), 3163-3170. DOI: 10.1016/j.engstruct.2010.06.004.
  26. Okazaki, T. and Engelhardt, M.D. (2007), "Cyclic loading behavior of EBF links constructed of ASTM A992 steel", J. Constr. Steel Res., 63, 751-765. DOI: 10.1016/j.jcsr.2006.08.004.
  27. Rahgozar, R., Mahmoudzadeh, Z., Malekinejad, M. and Rahgozar, P. (2015), "Dynamic analysis of combined system of framed tube and shear walls by Galerkin method using B-spline functions", Struct. Des. Tall Spec. Build., 24(8), 591-606. DOI: 10.1002/tal.1201.
  28. Rahgozar, P. (2020), "Free vibration of tall buildings using energy method and Hamilton's principle", Civil Eng. J., 6(5), 945-953. DOI: 10.28991/cej-2020-03091519.
  29. Shayanfar, M.A., Barkhordari, M.A. and Rezaeian, A.R. (2012). "Experimental study of cyclic behavior of composite vertical shear link in eccentrically braced frames", Steel Compos. Struct., 12(1), 13-29. https://doi.org/10.12989/scs.2012.12.1.013
  30. Shen, Y., Christopoulos, C., Mansour, N. and Tremblay, R. (2011). "Seismic design and performance of steel moment resisting frames with nonlinear replaceable links", J. Struct. Eng., 137(10), 1107-1117. DOI: 10.1061/(ASCE)ST.1943-541X.0000359.
  31. Shi, Y., Wang, M. and Wang, Y. (2012), "Experimental study of structural steel constitutive relationship under cyclic loading", J. Build Mater., 15(3), 293-300. DOI: 10.3969/j.issn.1007-9629.2012.03.001.
  32. Silvia, C., Nicola, M. and Walter, S. (2018). "Experimental and numerical assessment of EBF structures with shear links", Steel Compos. Struct., 28(2), 123-138. https://doi.org/10.12989/scs.2018.28.2.123.
  33. Tavakoli, R., Kamgar, R. and Rahgozar, R. (2019), "Seismic performance of outrigger braced system based on finite element and component mode synthesis methods", Iranian Jo. Science and Technology, Transactions of Civil Engineering, 1(1), 1-9. DOI: 10.1007/s40996-019-00299-3.