References
- Wess G, Reusch C. Evaluation of five portable blood glucose meters for use in dogs. J Am Vet Med Assoc 2000;216:203-209. https://doi.org/10.2460/javma.2000.216.203
- Cohen TA, Nelson RW, Kass PH, Christopher MM, Feldman EC. Evaluation of six portable blood glucose meters for measuring blood glucose concentration in dogs. J Am Vet Med Assoc 2009;235:276-280. https://doi.org/10.2460/javma.235.3.276
- Domori A, Sunahara A, Tateno M, Miyama TS, Setoguchi A, Endo Y. The clinical utility of two human portable blood glucose meters in canine and feline practice. Vet Clin Pathol 2014;43:55-62. https://doi.org/10.1111/vcp.12115
- Tauk BS, Drobatz KJ, Wallace KA, Hess RS. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples. J Am Vet Med Assoc 2015;246:1327-1333. https://doi.org/10.2460/javma.246.12.1327
- Paul AE, Shiel RE, Juvet F, Mooney CT, Mansfield CS. Effect of hematocrit on accuracy of two point-of-care glucometers for use in dogs. Am J Vet Res 2011;72:1204-1208. https://doi.org/10.2460/ajvr.72.9.1204
- Lane SL, Koenig A, Brainard BM. Formulation and validation of a predictive model to correct blood glucose concentrations obtained with a veterinary point-of-care glucometer in hemodiluted and hemoconcentrated canine blood samples. J Am Vet Med Assoc 2015;246:307-312. https://doi.org/10.2460/javma.246.3.307
- Johnson BM, Fry MM, Flatland B, Kirk CA. Comparison of a human portable blood glucose meter, veterinary portable blood glucose meter, and automated chemistry analyzer for measurement of blood glucose concentrations in dogs. J Am Vet Med Assoc 2009;235:1309-1313. https://doi.org/10.2460/javma.235.11.1309
- Brito-Casillas Y, Figueirinhas P, Wiebe JC, Lopez-Rios L, Perez-Barreto D, Melian C, Wagner AM. ISO-based assessment of accuracy and precision of glucose meters in dogs. J Vet Intern Med 2014;28:1405-1413. https://doi.org/10.1111/jvim.12397
- Neeley WE. Simple automated determination of serum or plasma glucose by a hexokinase-glucose-6 -phosphate dehydrogenase method. Clin Chem 1972;18:509-515. https://doi.org/10.1093/clinchem/18.6.509
- Cohn LA, McCaw DL, Tate DJ, Johnson JC. Assessment of five portable blood glucose meters, a point-of-care analyzer, and color test strips for measuring blood glucose concentration in dogs. J Am Vet Med Assoc 2000;216:198-202. https://doi.org/10.2460/javma.2000.216.198
- Brunner GA, Ellmerer M, Sendlhofer G, Wutte A, Trajanoski Z, Schaupp L, Quehenberger F, Wach P, Krejs GJ, Pieber TR. Validation of home blood glucose meters with respect to clinical and analytical approaches. Diabetes Care 1998;21:585-590. https://doi.org/10.2337/diacare.21.4.585
- Trajanoski Z, Brunner GA, Gfrerer RJ, Wach P, Pieber TR. Accuracy of home blood glucose meters during hypoglycemia. Diabetes Care 1996;19:1412-1415. https://doi.org/10.2337/diacare.19.12.1412
- Chan JC, Wong RY, Cheung CK, Lam P, Chow CC, Yeung VT, Kan EC, Loo KM, Mong MY, Cockram CS. Accuracy, precision and user-acceptability of self blood glucose monitoring machines. Diabetes Res Clin Pract 1997;36:91-104. https://doi.org/10.1016/S0168-8227(97)00036-3
- Ginsberg BH. Factors affecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol 2009;3:903-913. https://doi.org/10.1177/193229680900300438
- Rebel A, Rice MA, Fahy BG. Accuracy of point-of-care glucose measurements. J Diabetes Sci Technol 2012;6:396-411. https://doi.org/10.1177/193229681200600228
- Gerber KL, Freeman KP. ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine. Vet Clin Pathol 2016;45:10-27. https://doi.org/10.1111/vcp.12310
- Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987;10:622-628. https://doi.org/10.2337/diacare.10.5.622
- Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care 2000;23:1143-1148. https://doi.org/10.2337/diacare.23.8.1143
- Freckmann G, Schmid C, Baumstark A, Rutschmann M, Haug C, Heinemann L. Analytical performance requirements for systems for self-monitoring of blood glucose with focus on system accuracy: relevant differences among ISO 15197:2003, ISO 15197:2013, and current FDA recommendations. J Diabetes Sci Technol 2015;9:885-894. https://doi.org/10.1177/1932296815580160
- International Organization for Standardization. ISO 15197:2013. In Vitro Diagnostic Test Systems - Requirements for Blood-Glucose Monitoring Systems for Self-Testing in Managing Diabetes Mellitus. Geneva, Switzerland, International Organization for Standardization, 2013.
- Kilpatrick ES, Rumley AG, Myint H, Dominiczak MH, Small M. The effect of variations in haematocrit, mean cell volume and red blood cell count on reagent strip tests for glucose. Ann Clin Biochem 1993;30:485-487. https://doi.org/10.1177/000456329303000513
- Karon BS, Griesmann L, Scott R, Bryant SC, Dubois JA, Shirey TL, Presti S, Santrach PJ. Evaluation of the impact of hematocrit and other interference on the accuracy of hospitalbased glucose meters. Diabetes Technol Ther 2008;10:111-120. https://doi.org/10.1089/dia.2007.0257
- Tang Z, Lee JH, Louie RF, Kost GJ. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch Pathol Lab Med 2000;124:1135-1140. https://doi.org/10.5858/2000-124-1135-EODHLO
- Wiener K. The effect of haematocrit on reagent strip tests for glucose. Diabet Med 1991;8:172-175. https://doi.org/10.1111/j.1464-5491.1991.tb01566.x
- Tonyushkina K, Nichols JH. Glucose meters: a review of technical challenges to obtaining accurate results. J Diabetes Sci Technol 2009;3:971-980. https://doi.org/10.1177/193229680900300446