초록

In a reinforced concrete building different shapes of column are adopted depending on the structural orientation and the architectural aspect. When there is an increase in loading due to changes in usage or revision in the design codes these columns need to be strengthened for enhanced performance during their service life. Strengthening materials such as carbon fiber and glass fiber polymer has been successfully used however, due to high cost application other alternative materials need to be explore. Galvanized steel wire mesh (GSWM) is one of the suitable materials locally available. High tensile strength, low weight, corrosion resistance, easy installation, minimum change in dimensions of the sections and cost effectives are the advantages of GSWM. Therefore, in this paper, four different shapes of column such as circular, square, rectangular and L were wrapped with different layers GSWM and jacketed with mortar. All the specimens were tested under axial compression. The objective of the study is to investigate the effectiveness of GSWM as a confining material for strengthening of column having varying shape. Test results shows that the axial strength enhanced with wrapping of GSWM jacket and a circular column presented the highest load carrying capacity and ductility as compared to the others. From the study of 22 column specimens, it is found that axial load is increased upto 20% and 19% when circular and square column are strengthened with one wrap of GSWM respectively, while a rectangular and L column required a wraps of two and three layers respectively in order to achieved the same load capacity as that of a circular column. Based on the present study, it is concluded that GSWM can be effectively used for strengthening of different shapes of concrete columns economically.

키워드

참고문헌

  1. ACI Committee 549 (2008), "Thin Reinforced Cementitious Products & Ferrocement", American Concrete Institute, Farmington Hills, MI.
  2. Vuggumudi, S. and Alagusundaramoorthy, P. (2018), "Strengthened RC rectangular columns under combined axial and lateral loading: Analytical study", Structure, 14, 88-94. https://doi.org/10.1016/j.istruc.2018.02.007
  3. Afshin, H., Shirazi, M.R.N. and Abedi, K. (2019), "Experimental and numerical study about seismic retrofitting of corrosion-damaged reinforced concrete columns of bridge using combination of FRP wrapping and steel profiles", Steel Compos. Struct., 30, 231-251. https://doi.org/10.12989/SCS.2019.30.3.231
  4. Bentayeb, F., Tahar, K.A. and Chateauneuf, A. (2008), "New technique for reinforcement of concrete columns confined by embedded composite grid", Constr. Build. Mater., 22, 1624-1633. https://doi.org/10.1016/j.conbuildmat.2007.06.015
  5. Campione, G., Fossetti, M, Giacchino, C, and Minafo, G. (2014), "RC columns externally strengthened with RC jackets", Mater. Struct., 47, 1715-1728. https://doi.org/10.1617/s11527-013-0146-x
  6. Chellapandian, S., Prakash, S. and Sharma, A. (2017), "Strength and ductility of innovative hybrid NSM reinforced and FRP confined short RC columns under axial compression", Compos. Struct., 176, 205-216. https://doi.org/10.1016/j.compstruct.2017.05.033
  7. Choi, J.H. (2008), "Seismic retrofit of reinforced concrete circular columns using stainless steel wire mesh composite", Can. J. Civil Eng., 35(2), 140-147. https://doi.org/10.1139/L07-079
  8. Ghobarah, A. and Said, A. (2002), "Shear strengthening of beam-column joints", Eng. Struct., 24(7), 881-888. https://doi.org/10.1016/S0141-0296(02)00026-3
  9. Chen, L. and Ozbakkaloglu, T. (2016), "Corner strengthening of square and rectangular concrete-filled FRP tubes", Eng. Struct., 117, 486-495. https://doi.org/10.1016/j.engstruct.2016.03.031
  10. Cheng, H., Sotelino, E.D. and Chen, W. (2002), "Strength estimation for FRP wrapped reinforced concrete columns", Steel Compos. Struct., 2(1), 1-20. https://doi.org/10.12989/scs.2002.2.1.001
  11. Campione, G. (2008), "Analytical model for high-strength concrete columns with square cross-section", Struct. Eng. Mech., 28(3), 295-316. https://doi.org/10.12989/sem.2008.28.3.295
  12. Elwan, S.K. and Rashed, A.S. (2011), "Experimental behavior of eccentrically loaded R.C. short columns strengthened using GFRP wrapping", Struct. Eng. Mech., 39(2), 207-221. https://doi.org/10.12989/sem.2011.39.2.207
  13. Hodhod, O.A., Hassan, W., Hilal, M.S. and Bahnasawy, H. (2005), "Strength and ductility of biaxially loaded high strength RC short square columns wrapped with GFRP jackets", Struct. Eng. Mech., 20(6), 727-745. https://doi.org/10.12989/sem.2005.20.6.727
  14. Hwang, Y. H. Yang, K.H. and Choi, Y.S. (2020), "Axial performance of RC columns with glass-fiber grids as peripheral hoops", J. Struct. Integrity Maint., 5(1), 31-39. https://doi.org/10.1080/24705314.2019.1708050
  15. Habib, A. Yildirim, U. and Eren, O. (2020), "Column repair and strengthening using RC jacketing: a brief state-of-the-art review", Innovative Infrastruct. Solutions, 5, 75, https://doi.org/10.1007/s41062-020-00329-4.
  16. He, A., Cai, J., Chen, Q., Liu, Z. and Xu, J. (2016), "Behaviour of steel-jacket retrofitted RC columns with preload effects", Thin-Wall. Struct., 109, 25-39. https://doi.org/10.1016/j.tws.2016.09.013
  17. Hadi, M.N.S. (2007), "Behavior of FRP strengthened concrete columns under eccentric compression loading", Compos. Struct., 77(1), 92-96. https://doi.org/10.1016/j.compstruct.2005.06.007
  18. Hadi, M.N.S. and Zhao, H., (2011), "Experimental study of high-strength concrete columns confined with different types of mesh under eccentric and concentric loads", J. Mater. Civil Eng., 23(6), 823-832. https://doi.org/10.1061/(ASCE)MT.1943-5533.0000234
  19. Hadi, M.N.S. (2006), "Behavior of FRP wrapped normal strength concrete column under eccentric loading", Compos. Struct., 72, 503-511. https://doi.org/10.1016/j.compstruct.2005.01.018
  20. IS 456 (2000), "Plain and reinforced concrete - Code of Practice", Bureau of Indian Standard New Delhi.
  21. IS 2386a (1963), "Methods of test for aggregates for concrete - Part 1: Particle size and shape", Bureau of Indian Standard New Delhi.
  22. IS 2386b (1963), "Methods of Test for aggregates for concrete - Part 3: Specific gravity, Density, Voids, Absorption and Bulking", Bureau of Indian Standard New Delhi.
  23. IS: 12269 (2013), "Ordinary Portland Cement, 53 Grade-Specification", Bureau of Indian Standard New Delhi.
  24. IS 10262 (2009), "Guidelines for concrete mix design proportioning (CED 2: Cement and Concrete)", Bureau of Indian Standard New Delhi.
  25. IS: 516 (1959), Method of Tests for Strength of Concrete. Bureau of Indian Standard, New Delhi.
  26. Kumar, V. and Patel, P.V. (2016a), "Strengthening of axially loaded concrete columns using stainless steel wire mesh (SSWM)-numerical investigation", Struct. Eng. Mech., 60(6), 979-999. https://doi.org/10.12989/sem.2016.60.6.979
  27. Kumar, V. and Patel, P.V. (2016b), "Strengthening of axially loaded circular concrete columns using stainless steel wire mesh (SSWM) - Experimental investigation", Constr. Build. Mater., 124, 186-198. https://doi.org/10.1016/j.conbuildmat.2016.06.109
  28. Kaish, A., Alam, M.R., Jamil, M., Zain, M.F. M. and Wahed, M.A. (2012a), "Improved ferrocement jacketing for restrengthening of square RC short column", Constr. Build. Mater., 36, 228-237. https://doi.org/10.1016/j.conbuildmat.2012.04.083
  29. Kaish, A., Jamil, M., Raman, S.N., Zain, M.F.M. and Alam, M.R. (2012), "An approach to improve conventional square ferrocement jacket for strengthening application of short square RC column", Mater. Struct., 49, 1025-1037.
  30. Kondraivendhan, B. and Pradhan Bulu (2009). "Effect of ferrocement confinement on behavior of concrete", Constr. Build. Mater., 23, 1218-1222. https://doi.org/10.1016/j.conbuildmat.2008.08.004
  31. Marthong, C. (2019b), "Behavior of repaired RAC beam-column joints using steel welded wire mesh jacketed with cement mortar", Adv. Concrete Constr., 8(2), 91-100. https://doi.org/10.12989/acc.2019.8.2.091
  32. Marthong, C. (2019a), "Rehabilitation of exterior RC beam-column connections using epoxy resin injection and galvanized steel wire mesh", Earthq. Struct., 16(3), 253-263. https://doi.org/10.12989/EAS.2019.16.3.253
  33. Narmashiri, K. and Mehramiz, G. (2016), "Strengthening pf steel pipe section sunjected to transverse loads using CFRP", Struct. Eng. Mech., 60(1), 163-173. https://doi.org/10.12989/sem.2016.60.1.163
  34. Naeim, F. and Kelly, J.M. (199), "Design of seismic isolated structures from theory to practice", John Wiley & Sons, Inc.
  35. Ortlepp, R. and Ortlepp, S. (2017), "Textile reinforced concrete for strengthening of RC columns: A contribution to resource conservation through the preservation of structures", Constr. Build. Mater., 132, 150-160. https://doi.org/10.1016/j.conbuildmat.2016.11.133
  36. Parvin, A. and Wang, W. (2001), "Behavior of FRP jacketed concrete columns under eccentric loading", J. Compos. Constr., 5(3), 146-152. https://doi.org/10.1061/(ASCE)1090-0268(2001)5:3(146)
  37. Raval, R. and Dave, U. (2013), "Behavior of GFRP wrapped RC column of different shapes", Procedia Eng., 51, 240-249. https://doi.org/10.1016/j.proeng.2013.01.033
  38. Sarafraz, M.E. (2019). "Flexural strengthening of RC columns with low longitudinal steel ratio using GFRP bars", Int. J. Concrete Struct. Mater., 13(42). https://doi.org/10.1186/s40069-019-0354-z.
  39. Shannag, M. J., and Alhassan, M., A. (2005). "Seismic upgrade of interior beam-column sub-assemblages with high performance fiber reinforced concrete jackets." ACI, Structural Journals, 102(1), 131-138.
  40. Shannag M.J. and Ziyyad, T.B. (2007), "Flexural response of ferrocement with fibrous cementitious matrices", Constr. Build. Mater., 1198-1205.
  41. Tarabia, A.M. and Albakry, H.F. (2014), "Strengthening of RC columns by steel angles and strips", Alexandria Eng. J., 53, 615-626. https://doi.org/10.1016/j.aej.2014.04.005
  42. Yoddumrong, P., Rodsin, K. and Katawaethwarag, S. (2020), "Seismic strengthening of low-strength RC concrete columns using low-cost glass fiber reinforced polymers (GFRPs)", Case Studies in Construction Materials, 13, e00383. https://doi.org/10.1016/j.cscm.2020.e00383
  43. Zhang, B., Yang, Y., Wei1, Y., Liu, R., Ding, C. and Zhang, K. (2015), "Experimental study on seismic behavior of reinforced concrete column retrofitted with prestressed steel strips", Struct. Eng. Mech., 55(6), 1139-1155. https://doi.org/10.12989/sem.2015.55.6.1139