DOI QR코드

DOI QR Code

Behavior of SFRC interior beam-column joints under cyclic loading

  • Received : 2020.04.23
  • Accepted : 2020.06.09
  • Published : 2020.09.25

Abstract

In this paper, the behavior of interior steel fiber reinforced concrete beam - column joints (BCJs) under cyclic loading is investigated. An experimental program including tests on twelve reinforced concrete (BCJs) specimens under cyclic loading was carried out. The test specimens are divided into two groups having different geometry: group (G1) (symmetrical BCJs specimens) and group (G2) (nonsymmetrical BCJs specimens). The parameters considered in this study are the steel fibers (SFs) content by volume of concrete (Vf), the spacing of shear reinforcement at the joint region, and the area of longitudinal flexural reinforcement. Test results show that the addition of 0.5% SFs with stirrups spacing S=Smax has effectively enhanced the overall performance of BCJs with respect to energy dissipation, ductility ratio, spreading and width of cracks. The failure of specimens is governed mainly by the formation of a plastic hinge at the face column and outside the beam-column junction. Secondary shear cracks were also observed in the beam-column junctions.

Keywords

References

  1. ACI 544.1R-96. (2002), State-of-the-Art Report on Fiber Reinforced Concrete.
  2. ACI Committee 352R-02. (2002), Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures. Reported by Joint ACI-ASCE Committee 352.
  3. ASTM C 78-2002. (2002), Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third- Point Loading). Annual Book of ASTM Standards, American Society for Testing and Materials.
  4. ASTM C496 / C496M-2004. (2004),Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens. ASTM International, West Conshohocken, PA.
  5. B.S. 1881 (1989), Method for determination of compressive strength of concrete cubes. British Standards Institution, Part 116.
  6. Banthia, N., Yan, C. and Bindiganavile, V. (2000), "Development and application of high-performance hybrid fiber- reinforced concrete", Proceedings of the 5th RILEM International Symposium on Fiber-Reinforced Concrete BEFIB, RILEM Bagneux, France.
  7. British Standards Institution, BS 5328 (1997), "Methods for specifying concrete mixes", Issue 2.
  8. Ganesh, K.D. and Prabavathy, S. (2015), "Experimental study on seismic performance in beam- column joint using hybrid fibers", Int. J. Sci. Eng. Appl., 4(3),134-137. https://doi.org/10.7753/IJSEA0403.1011
  9. Kang, S.B. and Tan, K.H. (2015), "Behaviour of precast concrete beam-column sub-assemblages subject to column removal", Eng. Struct., 93, 85-96. https://doi.org/10.1016/j.engstruct.2015.03.027
  10. Keerthana, J.D. and Reddy, C.S. (2014), "Experimental investigation on hybrid steel fiber reinforced concrete beam- column joints under cyclic loading", IJRST, 1, 6-11.
  11. Kim, J. and LaFave, J.M. (2009), "Joint shear behavior of reinforced concrete beam-column connections subjected to seismic lateral loading", NSEL Report Series Report No. NSEL-020, Department of Civil and Environmental Engineering, the University of Illinois at Urbana-Champaign.
  12. Kumar, S. (1988), "A Study of Reinforced Concrete Beam-Column Joints under Uni-Axial Bending", M. Tech, Dissertation, Inst. Of Technology, Benara Hindu University, Varanasi.
  13. Kumar, V., Nautiyalil, B.D. and Kumar, S. (1991), "A study of exterior beam-column joints", The Concrete J., 65, 2821-2836.
  14. Liang, X.W., Wang, Y.J., Tao, Y. and Deng, M.K. (2016), "Seismic performance of fiber-reinforced concrete interior beam-column joints", Eng. Struct., 126, 432-445. https://doi.org/10.1016/j.engstruct.2016.08.001
  15. Moehle, J.P., Hooper, J.D. and Lubke, C.D. (2008), "Seismic design of reinforced concrete special moment frames: A guide for practicing engineers",US Department of Commerce.
  16. Nguyen, X.H., Le, D.D., Nguyen, Q.H. and Nguyen, H.Q. (2020), "Seismic performance of RCS beam-column joints using fiber reinforced concrete", Earthq. Struct., 18(5), 599-607. https://doi.org/10.12989/EAS.2020.18.5.599
  17. Nimse, R.B., Joshi, D.D. and Patel, P.V. (2014), "Behavior of wet precast beam- column connections under progressive collapse scenario: an experimental study", IJASE, 6, 149-159.
  18. Oinam, R.M., Kumar, P.C.A. and Sahoo, D.R. (2019), "Cyclic performance of steel fiber-reinforced concrete exterior beam-column joints", Earthq. Struct., 16(5), 533-546. https://doi.org/10.12989/EAS.2019.16.5.533
  19. Paulay, T., Park, R. and Priestey, M.J.N. (1978), "Reinforced concrete beam-column joints under seismic actions", ACI J., 75, 585-593.
  20. Qi, J., Wang, J. and Feng, Y. (2019), "Shear performance of an innovative UHPFRC deck of composite bridge with coarse aggregate", Adv. Concrete Constr., 7(4), 219-229. https://doi.org/10.12989/acc.2019.7.4.219.
  21. Romanbabu, M.O., Choudhury, A.M. and Laskar, A.I. (2013), "Experimental study on beam- column joint with fibers under cyclic loading", IOSR Journal of Engineering, 3,13-23. https://doi.org/10.9790/3021-03721323
  22. Sara, M., Abbas, A. and Masoud, S. (2015), "Behavior of interior RC wide and conventional beam-column roof joints under cyclic load", Structural Engineering Division, Faculty of Civil and Environmental Engineering, Tarbiat Modares University, Tehran, Iran.
  23. Sarmiento, P.A., Torres, B., Ruiz, D.M., Alvarado, Y.A., Gasch, I. and Machuca, A.F. (2019), "Cyclic behavior of ultra-high performance fiber reinforced concrete beam-column joint", Struct. Concrete, 20(1), 348-360. https://doi.org/10.1002/suco.201800025
  24. SikaViscoCrete -5930. (2010), Product data sheet. Edition 6, 2010.Version no. 01.10
  25. Sohailuddin, S.S. and Shaikhm, M.G. (2013), "Finite element modeling of reinforced concrete beam column joint using ANSYS", Int. J. Struct. Civ. Eng. Res., 2, 22-31.
  26. Sorelli, L.G. (2003), Some Studies on the Assessment of the Toughness of Steel Fiber Reinforced Concrete with Emphasis on Hybrid Fiber Systems. Ph.D., Department of Civil Engineering of the University of Brescia, Brescia, Italy.
  27. Sorelli, L.G., Meda, A. and Plizzari, G.A. (2005), "Bending and uniaxial tensile tests on concrete reinforced with hybrid steel fibers", J. Mater. Civ. Eng., 17, 519-527. https://doi.org/10.1061/(ASCE)0899-1561(2005)17:5(519)
  28. Sorelli, L.G., Meda, A. and Plizzari, G.A. (2006), "Steel fiber concrete slabs on ground: A structural matter", ACI Struct. J., 103, 551-558.
  29. UFC 4-023-03 DoD (2016), "Design of buildings to resist progressive collapse. USA, http://dod.wbdg.org/.
  30. Xilin, L., Tonny, H., Urukap, Sen Li and Fangshu Lin (2012), "Seismic behavior of interior RC beam-column joints with additional bars under cyclic loading", Earthq. Struct., 3(1), 37-57. https://doi.org/10.12989/eas.2012.3.1.037
  31. Zhou, H. and Zhang, J. (2014), "Interaction of internal forces of interior beam-column joints of reinforced concrete frames under seismic action", Struct. Eng. Mech., 52(2), 427-443. https://doi.org/10.12989/sem.2014.52.2.427