DOI QR코드

DOI QR Code

Mechanically fastened shear connectors in prefabricated concrete slabs - experimental analysis

  • Gluhovic, Nina (Department of Materials and Structures, Faculty of Civil Engineering University of Belgrade) ;
  • Markovic, Zlatko (Department of Materials and Structures, Faculty of Civil Engineering University of Belgrade) ;
  • Spremic, Milan (Department of Materials and Structures, Faculty of Civil Engineering University of Belgrade) ;
  • Pavlovic, Marko (Department of Engineering Structures, Faculty of Civil Engineering and Geosciences, Delft University of Technology)
  • 투고 : 2019.03.18
  • 심사 : 2020.07.22
  • 발행 : 2020.08.25

초록

Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen's layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.

키워드

과제정보

This investigation is supported by the Serbian Ministry of Education, Science and Technological Development through the TR-36048 project. The authors are grateful to Hilti Corporation in Schaan, Liechtenstein and Laboratory of Materials at the University of Belgrade, Faculty of Civil Engineering for their technical support.

참고문헌

  1. ANSI/AISC 360-05 (2005), An American National Standard - Specification for structural steel buildings, American Institute of Steel Construction; Chicago, Illinois.
  2. Arrayago, I., Real, E. and Gardner, L. (2015), "Description of stress-strain curves for stainless steel alloys", Materials & Design, 87, 540-552. doi: 10.1016/J.MATDES.2015.08.001.
  3. Ataei, A., Moradi M., Valipuor, R.H. and Bradford, A.M. (2018), "Finite element modelling of demountable precast reinforced concrete deck slabs with external confining system", J. Constr. Steel Res., 151, 204-215. doi: 10.1016/j.jcsr.2018.09.023.
  4. Beck, H., Siemers, M. and Reuter, M. (2011), Steel Construction Calendar 2011 - Powder-Actuated Fasteners and Fastening Screws in Steel Construction, Ernst & Sohn.
  5. Crisinel, M. (1990), "Partial-interaction analysis of composite beams with profiled sheeting and non-welded shear connectors", J. Constr. Steel Res., 15, 65-98. https://doi.org/10.1016/0143-974X(90)90043-G
  6. EN 10002-1 (2001), Metallic materials - Tensile testing - Part 1: Method of test at ambient temperature, European Committee for Standardization; Brussels, Belgium.
  7. EN 10025-2 (2004), Hot rolled products of structural steels. Part 2: Technical delivery conditions for non-alloy structural steels, European Committee for Standardization; Brussels, Belgium.
  8. EN 10130:2006 (2006), Cold rolled low carbon steel flat products for cold forming - Technical delivery conditions, European Committee for Standardization; Brussels, Belgium.
  9. Eurocode (2010), Basis of structural design, European Committee for Standardization; Brussels, Belgium.
  10. Eurocode 2 (2004), Design of Concrete Structures. Part 1-1: General rules and rules for buildings, European Committee for Standardization; Brussels, Belgium.
  11. Eurocode 4 (2004), Design of composite steel and concrete structures. Part 1-1: General rules and rules for buildings, European Committee for Standardization; Brussels, Belgium.
  12. ETA-15/0876 (2016), European Technical Assessment, Deutsches Institut fur Bautechnik, Berlin.
  13. Feidaki, E., Vasdravellis, G., He, J. and Wang, S. (2019), "Steelyielding demountable shear connector for composite floors with precast hollow-core slab units", J. Struct. Eng., 145(8), 1-17, doi: 10.1061/(ASCE)ST.1943-541X.0002356.
  14. Fontana, M. and Bärtschi, R. (2002), "New types of shear connectors with powder-actuated fasteners", Institute of Structural Engineering Swiss Federal Institute of Technology, Zurich
  15. Goldspiegel, F., Mocellin, K. and Michel, P. (2019), "Numerical modelling of high-speed nailing process to join dissimilar materials: Metal sheet formulation to simulate nail insertion stage", J. Mater. Process. Technol. 267, 414-433. doi: 10.1016/j.jmatprotec.2018.10.022.
  16. Johnson, R.P. and Molenstra, I.N. (1991), "Partial shear connection in composite beams for buildings", Proceedings of the Institution of Civil Engineers, 91(4), 679-704. doi: 10.1680/iicep.1991.17485.
  17. Le, V.P.N., Bui, D.V., Chu, T.H.V., Kim, I.T., Ahn, J.H. and Dao, D.K. (2017), "Behavior of steel and concrete composite beams with a newly puzzle shape of crestbond rib shear connector: an experimental study", Struct. Eng. Mech., 60(6), 1001-1019. doi: 10.12989/sem.2016.60.6.1001.
  18. McComb, C. and Tehrani, F.M. (2015), "Enhancement of shear transfer in composite deck with mechanical fasteners", Eng. Struct., 88, 251-261. doi: 10.1016/j.engstruct.2015.01.046.
  19. Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X. (2016), "Bolted and welded connectors for the rehabilitation of composite beams", J. Constr. Steel Res., 125, 61-73. doi: 10.1016/j.jcsr.2016.06.003.
  20. Pavlovic, M., Markovic, Z., Veljkovic, M. and Budevac, D. (2013), "Bolted shear connectors vs. headed studs behaviour in push-out tests", . doi: doi.org/10.1016/j.jcsr.2013.05.003.
  21. Rehman, N., Lam, D., Dai, X. and Ashour, A.F. (2016), "Experimental study on demountable shear connectors in composite slabs with profiled decking", J. Constr. Steel Res., 122, 178-189. doi: 10.1016/j.jcsr.2016.03.021.
  22. Spremic, M., Pavlovic, M., Markovic, Z., Veljkovic, M. and Budjevac, D. (2018), "FE validation of the equivalent diameter calculation model for grouped headed studs", Steel Compos. Struct., 26(3), 375-386. doi: 10.12989/scs.2018.26.3.375.
  23. Standard specifications for steel and composite structures (2009), JSCE Japan Society of Civil Engineers, Tokyio, Japan.
  24. Suwaed, A.S.H. and Karavasilis, T.L. (2017), "Novel demountable shear connector for accelerated disassembly, repair, or replacement of precast steel-concrete composite bridges", J. Bridge Eng., 22(9), 1-18. doi: 10.1061/(ASCE)BE.1943-5592.0001080.
  25. Tahir, M., Shek, P.N. and Tan, C.S. (2009), "Push-off tests on pin-connected shear studs with composite steel-concrete beams", Constr. Build. Mater., 23(9), 3024-3033. doi:10.1016/j.conbuildmat.2009.04.008.
  26. Vianna, J. da C., Andrade, de S.A.L., Vellasco, P.C.G. da S. and Costa-Neves, L.F. (2013), "Experimental study of perfobond shear connectors in composite construction", J. Constr. Steel Res., 81, 62-75. doi: 10.1016/j.jcsr.2012.11.002.
  27. Wang, Y.H., Yu, J., Liu, J.P., and Chen, Y.F. (2019), "Shear behavior of shear stud groups in precast concrete decks", Eng. Struct., 187, 73-84. doi: 10.1016/j.engstruct.2019.02.002.