Here we review the evolutionary history of radiation therapy technology through the festschrift of articles in celebration of the 30th anniversary of Korean Society of Medical Physics (KSMP). Radiation therapy technology used in clinical practice has evolved over a long period of time. Various areas of science, such as medical physics, mechanical engineering, and computer engineering, have contributed to the continual development of new devices and techniques. The scope of this review was restricted to two areas; i.e., output energy production and functional development, because it is not possible to include all development processes of this technology due to space limitations. The former includes the technological transition process from the initial technique applied to the first model to the latest technique currently used in a variety of machines. The latter has had a direct effect on treatment outcomes and safety, which changed the paradigm of radiation therapy, leading to new guidelines on dose prescriptions, innovation of dose verification tools, new measurement methods and calculation systems for radiation doses, changes in the criteria for errors, and medical law changes in all countries. Various complex developments are covered in this review. To the best of our knowledge, there have been few reviews on this topic and we consider it very meaningful to provide a review in the festschrift in celebration of the 30th anniversary of the KSMP.

키워드

참고문헌

  1. Case JT, Buschke F. History of radiation therapy. Progress in radiation therapy. New York: Grune & Stratton; 1958:13-41.
  2. Lederman M. The early history of radiotherapy: 1895-1939. Int J Radiat Oncol Biol Phys. 1981;7:639-648. https://doi.org/10.1016/0360-3016(81)90379-5
  3. Holsti LR. Development of clinical radiotherapy since 1896. Acta Oncol. 1995;34:995-1003. https://doi.org/10.3109/02841869509127225
  4. Senn N. Case of spleno-medullary leukemia successfully treated by use of roentgen ray. Med Rec N Y. 1903;63:281-282.
  5. Thames HD Jr. Early fractionation methods and the origins of the NSD concept. Acta Oncol. 1988;27:89-103. https://doi.org/10.3109/02841868809090329
  6. Quimby EH. The history of dosimetry in roentgen therapy. Am J Roentgenol Radium Ther. 1945;54:688-703.
  7. Buschek F. Radiation therapy: the past, the present, the future. Paper presented at: Fifty-first Annual Meeting of the American Radium Society; 1969 Apr 27-30; Pennsylvania, USA. p. 236.
  8. Kim KE. Past Footprints. Seoul: The Department of Radiation Oncology, Yonsei University College of Medicine; 2009:46-53.
  9. Webb S, Evans PM. Innovative techniques in radiation therapy: editorial, overview, and crystal ball gaze to the future. Semin Radiat Oncol. 2006;16:193-198. https://doi.org/10.1016/j.semradonc.2006.04.001
  10. Brahme A, Roos JE, Lax I. Solution of an integral equation encountered in rotation therapy. Phys Med Biol. 1982;27: 1221-1229. https://doi.org/10.1088/0031-9155/27/10/002
  11. Palta JR, Mackie R, Chen Z. Intensity-modulated radiation therapy- the state of the art. Madison: Medical Physics Publishing; 2003:1-23.
  12. Royal College of Radiologists. Development and implementation of conformal radiotherapy in the United Kingdom. London: Royal College of Radiologist; 2002.
  13. Sternick ES. The theory and practice of intensity modulated radiation therapy. Madison: Advanced Medical Publishing; 1997.
  14. Cho B. Intensity-modulated radiation therapy: a review with a physics perspective. Radiat Oncol J. 2018;36:1-10. https://doi.org/10.3857/roj.2018.00122
  15. Thwaites DI, Tuohy JB. Back to the future: the history and development of the clinical linear accelerator. Phys Med Biol. 2006;51:R343-R362. https://doi.org/10.1088/0031-9155/51/13/R20
  16. Miller CW. An 8 MeV linear accelerator for x-ray therapy. Manchester: Metropolitan-Vickers Electrical Co.; 1955.
  17. Miller CW. Linear accelerators in clinical service. Manchester: Metropolitan-Vickers Electrical Co.; 1956.
  18. Karzmark CJ, Pering NC. Electron linear accelerators for radiation therapy: history, principles and contemporary developments. Phys Med Biol. 1973;18:321-354. https://doi.org/10.1088/0031-9155/18/3/001
  19. Hansen WW. A type of electrical resonator. J Appl Phys. 1938;9:654-663. https://doi.org/10.1063/1.1710371
  20. Boot H, Randall JT. Historical notes on the cavity magnetron. IEEE Trans Electron Devices. 1976;23:724-729. https://doi.org/10.1109/T-ED.1976.18476
  21. Varian RH, Varian SF. A high frequency oscillator and amplifier. J Appl Phys. 1939;10:321. https://doi.org/10.1063/1.1707311
  22. Knapp EA, Knapp BC, Potter JM. Standing wave high energy linear accelerator structures. Rev Sci Instrum. 1986;39: 979-991. https://doi.org/10.1063/1.1683583
  23. Maxim PG, Tantawi SG, Loo BW Jr. PHASER: A platform for clinical translation of FLASH cancer radiotherapy. Radiother Oncol. 2019;139:28-33. https://doi.org/10.1016/j.radonc.2019.05.005
  24. Vozenin MC, Baumann M, Coppes RP, Bourhis J. FLASH radiotherapy international workshop. Radiother Oncol. 2019;139:1-3. https://doi.org/10.1016/j.radonc.2019.07.020
  25. Vozenin MC, De Fornel P, Petersson K, Favaudon V, Jaccard M, Germond JF, et al. The advantage of FLASH radiotherapy confirmed in mini-pig and cat-cancer patients. Clin Cancer Res. 2019;25:35-42. https://doi.org/10.1158/1078-0432.CCR-17-3375
  26. Favaudon V, Caplier L, Monceau V, Pouzoulet F, Sayarath M, Fouillade C, et al. Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice. Sci Transl Med. 2014;6:245ra93. https://doi.org/10.1126/scitranslmed.3008973
  27. Beyreuther E, Brand M, Hans S, Hideghety K, Karsch L, Lessmann E, et al. Feasibility of proton FLASH effect tested by zebrafish embryo irradiation. Radiother Oncol. 2019; 139:46-50. https://doi.org/10.1016/j.radonc.2019.06.024
  28. Skouboe S, Ravkilde T, Bertholet J, Hansen R, Worm ES, Muurholm CG, et al. First clinical real-time motion-including tumor dose reconstruction during radiotherapy delivery. Radiother Oncol. 2019;139:66-71. https://doi.org/10.1016/j.radonc.2019.07.007