원전 Mixing Tee에서의 고주기 열피로 평가

Evaluation of High Cycle Thermal Fatigue on Mixing Tee in Nuclear Power Plant

  • 이선기 (동신대학교 에너지기계설비전공)
  • 투고 : 2020.02.17
  • 심사 : 2020.03.23
  • 발행 : 2020.06.30

초록

In nuclear power plants, there is a risk of thermal fatigue in equipment and piping affecting system soundness because the temperature change of the system accompanies in every operation and shutdown. Therefore, in order to prevent the excess of the fatigue limit during the lifetime of plants, the fatigue limit of each piping material is determined in the designing stage. However, there are many cases where equipment or piping is locally subjected to thermal fatigue that is not considered in the design, resulting in damage to the equipment and piping, and failure during operation. Currently, local thermal fatigue generation mechanisms that are not taken into account in the design stage are gradually being identified. In this paper, the effects of the fluid temperature fluctuations on the piping soundness due to the mixing of hot and cold water, one of the local thermal fatigue generating mechanisms, were evaluated.

키워드

참고문헌

  1. EPRI, 2001, "Interim Thermal Fatigue Management Guideline (MRP-24)", EPRI TR-1000701
  2. EPRI, 1994, "Thermal Stratification, Cycling and Striping(TASCS)", EPRI TR-103581
  3. Westinghouse Report, 1989, "Evaluation of Thermal Stratification for the VOGTLE Unit 2 Pressurizer Surge Line", WCAP-12218
  4. NRC, 1988, "Thermal stress in piping connected to reactor coolant system", NRC Bulletin 88-08
  5. Sun-Ki Lee, 2016, "Review for Thermal Stratification on Piping System in Korea Nuclear Power Plant", Trans. of the KPVP, Vol.12 No.02, pp.1-8
  6. Hag-Ki Yeom, Man-Heung Park, Sang-Nung Kim, 1996, "The Unsteady 2-D Numerical Analysis in a Horizontal Pipe with Thermal Stratification Phenomena", Journal of the Korean Nuclear Society, Vol.28 No.1, pp.27-35
  7. H. K. Yeom, M. H. Park, 1996, "Unsteady Thermal Stratified Flow and Heat Transfer in a Horizontal Feedwater Pipe", KSME Journal(B), Vol.20 No.2, pp.680-688
  8. J. C. Jo, Y. I. Kim, B. K. Min, K. M. Oh, S. K. Choi, 1998, " Numerical Analysis of Thermally Stratified Flow in the Pressurizer Surge Line", Korea Nuclear Engineering and Technology Proceeding, pp.133
  9. J. C. Jo, S. J. Cho, Y. I. Kim, J. Y. Park, S. J. Kim, S. K. Choi, 2001, "Prediction of Transient Temperature Distributions in the Wall of Curved Piping System Subjected to Internally Thermal Stratification Flow", KSME Proceeding, pp.474-481
  10. Jong Chull Jo, Hoon-Ki Choi, 2002, "Numerical Analysis of Conjugate Heat Transfer in a Curved Piping System Subjected to Internal Stratified Laminar Flow", Journal of Compute Fluids Eng., Vol.7 No.3, pp.35-43
  11. Jong Chull Jo, Byung Soon Jim, Hoon Ki Choi, 2002, " Three Dimensional Heat Transfer Analysis of a Thermally Stratified Pipe Flow", Proceeding of The Second National Congress on Fluids Engineering, pp.103-106
  12. S. K. Lee, H. Lee, T. R. Kim, B. N. Kim, 1998, "Evaluation of Thermal Stratification on Surge Line in Kori Nuclear Power Plant Unit 4", Korea Nuclear Engineering and Technology Proceeding, pp.857-863
  13. Dho-In Song, Young-Don Choi, Min-Su Park, 2001, "Experimental Research for Identification of Thermal Stratification Phenomena in the Nuclear Power Plnat Emergency Core Coolant System(ECCS)", KSME Proceeding, pp.735-740
  14. Seong-Min Han, Yong Don Choi, Min Soo Park, 2006, "Study of Thermal Stratification into Leaking Flow in the Nuclear Power Plant, Emergency Core Coolant System", Korea Air-Conditioning and Refrigeration Engineering, Vol.18 No.3, pp.202-210
  15. Jeong Soon Park, Young Hwan Choi, Kuk Hee Lim, Sun Hye Kim, 2010, "Thermal Cycling Screening Criteria to RCS Branch Lines in Domestic Nuclear Power Plant", Trans. of the KPVP, Vol.6 No.2 pp.54-60
  16. Sun-Hye Kim, Jae-Boong Choi, Jung-Soon Park, Young-Hwan Choi, Jin-Ho Lee, 2013, "A Coupled CFD-FEM Analysis on the Safety Injection Piping Subjected to Thermal Stratification", Nuclear Engineering and Technology, Vol.45 No.2, pp.237-248 https://doi.org/10.5516/NET.09.2012.038
  17. Man-Heung Park, Kwang-Chu Kim, Seung-Chul Lee, 2006, "A Study on the Mitigation Schemes of Thermal Stratification Phenomenon in a Branch Piping", Korea Air-Conditioning and Refrigeration Engineering, Vol.18 No.7, pp.603-611
  18. M. H. Park, K. C. Kim, K. H. Kim, 2003, "An Analysis on Thermal Stratification in Residual Heat Removal System Piping of Nuclear Power Plant", KSME Proceeding, pp.1597-1602
  19. Sun-Ki Lee, Sang-Kook Lee, Wook-Ryun Lee, Hwan-Hee Lee, Tae-Ryong Kim, 2004, "Evaluation of High Cycle Thermal Fatigue Caused by Mixing Flow at RHR System", Korea Nuclear Engineering and Technology Proceeding, pp.1-15
  20. JSME, 2003, "Assessment guide lines for high cycle thermal fatigue of piping system", JSME S 017