DOI QR코드

DOI QR Code

Design of the Structural Connection for Lightweight Structure Application

경량구조 적용을 위한 구조 접합부 설계

  • Received : 2019.12.18
  • Accepted : 2020.03.27
  • Published : 2020.06.30

Abstract

The structural connection design for lightweight structure application is presented in this paper. Modeling of the welding zone and the bolted connection are suggested. For reliability verification of the established models, nonlinear analysis is performed and comparisons are made with the experimental data showing good agreement. Through comparison study, suitable welding method for structure materials is investigated. Also, stability analysis is performed by fracture load simulation for different number and position of bolts. Finally, based on the structural connection models, the lightweight structure is modeled and structural analysis was performed. Stability analysis of structural connection for lightweight structure design, through combination of welding and bolting process, showed a 31.4% decrease in the maximum stress compared to the structure without the structural connections. Importance of structural connection design is highlighted for lightweight structure stability analysis.

본 논문에서는 경량구조 적용을 위한 구조 접합부 설계를 제시하였다. 압력에 대한 구조 안정성 연구를 위하여 용접부 접합부와 볼트 접합부에 대한 모델을 설계하였다. 확립된 모델의 신뢰성 검증을 위하여, 비선형 해석을 수행하였고, 실험결과와 비교하였을 때 유사한 결과를 확인하였다. 또한 비교연구를 통하여 구조설계 재료와 적합한 용접방법을 선택하였으며, 볼트의 개수와 위치에 따른 파단하중 시뮬레이션을 진행하여 응력에 따른 안정성을 분석하였다. 마지막으로, 접합부 모델을 기반으로 경량 구조를 모델링하고 구조 해석을 수행하였다. 그 결과, 용접부와 볼트체결을 적용하여 설계된 구조가 접합부를 적용하지 않은 구조에 비해 최대응력이 31.4% 감소함을 확인하였다. 이 결과를 토대로, 경량구조의 안정성 해석 시 접합부 모델링의 필요성을 확인하였다.

Keywords

References

  1. Ahn, J. H., You, J. M., Huh, J., Kim, I. T. and Jeong, Y. S. (2017), Residual clamping force of bolt connections caused by sectional damage of nuts, Journal of Constructional Steel Research, Vol. 136, pp. 204-214 doi:10.1016/j.jcsr.2017.05.019
  2. Choi, S. M., Lee, S. H. and Kim, J. H. (2004), A Study on the Ductility Capacity of Tension Joint with High-Strength Bolted Split-Tee, proceeding of the Architectural Institute of Korea Structure & Construction, Vol. 24, No. 2, pp. 43-46.
  3. Cho, S. S. and Shin, C. (2010), Finite Element Analysis of Mechanical Behavior of Bolt Tightened in Plastic Region, Transactions of the Korean Society of Automotive Engineers, Vol. 18, No. 3, pp. 37-42.
  4. Debski, H., Teter, A., Kubiak, T. and Samborski, S. (2016), Local buckling, post-buckling and collapse of thin-walled channel section composite columns subjected to quasi-static compression, Composite Structures, Vol. 136, pp. 593-601 doi:10.1016/j.compstruct.2015.11.008
  5. Hanamici, M.. (2017), High Strength Hexagon Bolts (JIS B1186)from https://id.scribd.com
  6. Ishigami, A., Roy, M. J., Walsh, J. N. and Withers. P. J. (2017), The effect of the weld fusion zone shape on residual stress in submerged arc welding, International Journal of Advanced Manufacturing Technology, Vol. 90, No. 9-12, pp. 3451-3464 doi:10.1007/s00170-016-9542-z
  7. Jam, J. E. and Ghaziani, N. O. (2011), Numerical and experimental investigation of bolted joints, International Journal of Engineering, Science and Technology, Vol. 3, No. 8, pp. 285-296 doi:10.4314/ijest.v3i8.22
  8. Jin, D. and Park, S. H. (2012), Modeling Scheme for Weld-Jointed Parts for Precise Structural Analysis of Large-Scale Structures, Transactions of the Koreans Society of Mechanical Engineers A, Vol. 36, No. 10, pp. 1195-1203 doi:10.3795/KSME-A.2012.36.10.1195
  9. Kim, Y. H., Lee, S. H. and Choi, S. M. (2009), Evaluation of Ultimate Strength of Long-Span Single Story Buildings with P.E.B(Pre-Engineered Building) System, Journal of Architectural Institute of Korea Structure & Construction, Vol. 25, No. 10, pp. 11.
  10. Kim, S. J., Jang, S. K and Han, M. S. (2007), Evaluation of Mechanical Characteristic of Al Alloy for Ship's Welded with Various Welding Techniques, Korean Society of Marine Environment & Safety, Vol. 13, No. 3, pp. 223-228.
  11. Kim, S. J and Jeong, H. C. (2016), Development of Structural Steel and Trend of Welding Technology, Journal of Welding and Joining, Vol. 34, No. 1, pp. 7-20 doi:10.5781/JWJ.2016.34.1.7
  12. Kim, T. S., Jeong, H. Y., Kim, S. H. and Lee, Y. T.(2009), An Experimental Study on Ultimate Strength and Curling Behavior of Thin-walled Steel Bolted Connections with Variables of End Distance, Journal of Architectural Institute of Korea Structure & Construction, Vol. 25 No. 4, pp.49-56 doi:10.5659/JAIK_SC.2014.30.3.049
  13. Kweon, O. S., Yoo, Y. H., Kim, H. Y. and Min, S. H. (2012), An Experimental Study on Fire Safety Performance of Glass Wool Sandwich Panel, Journal of Korean Institute of Fire Science and Engineering, Vol. 26, No. 5, pp. 21-27 doi:10.7731/KIFSE.2012.26.5.021
  14. Li, Y., Song, R. and Lindt, J. W. V. D. (2014), Collapse Fragility of Steel Structures subjected to Earthquake mainshock-Aftershock Sequences, Journal of Structural Engineering, Vol. 140, No. 12 doi: 10.1061/(ASCE)ST.1943-541X.0001019
  15. Li, F., Quan, X., Jia, Y., Wang, B., Zhang, G. and Chen, S. (2017), The Experimental Study of the Temperature Effect on the Interfacial Properties of Fully Grouted Rock Bolt, Applied Sciences, Vol. 7, No. 4, pp. 327 doi:10.3390/app7040327
  16. Liu, W., Pan, H., Li, L., Lv, H., Wu, Z., Cao, F. and Zhu, J. (2017), Corrosion behavior of the high strength low alloy steel joined by vertical electrogas welding and submerged arc welding methods, Journal of Manufacturing Processes, Vol. 25, pp. 418-425 doi:10.1016/j.jmapro.2016.12.011