Building regulations and codes for thermal insulation have been continuously strengthened in an effort to reduce energy use in buildings. The more stringent building energy regulations demand insulation materials with better performance for buildings. Phenolic foam insulation is one of the high-performance insulation materials for buildings. Its thermal conductivity is about 0.018 ~ 0.020 W/(m·K), which shows better thermal insulation performance than conventional insulation materials. Phenolic foam insulation is widely used in the building industry, as it can satisfy the revised building code for thermal performance and fire resistance. However, there have been concerns about the emission of harmful gas, such as formaldehyde from the phenolic foam insulation material. This paper evaluates the effect of phenolic foam insulation on the indoor air quality of a house through an experiment within an apartment unit. At first, the formaldehyde emission from the phenolic foam board, and all other materials used for the experiment were measured according to their test standards. Then, the indoor air quality of the apartment unit was investigated after applying all materials, including phenolic foam board as insulation.

Keywords

Acknowledgement

이 연구는 2018년도 정부(교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 이공학개인기초 후속연지원사업의 지원을 받아 수행한 연구과제입니다(NRF-2018R1D1A1A09083870).

References

  1. Korea Energy Agency, (2019). Commentary on the design criteria for energy conservation of buildings (건축물의 에너지절약 설계기준 해설서)
  2. National Law Information Center (2019). Enforcement Decree of the Building Act
  3. Park, T. S., & Kim, K. S. (2019). A Study on Physical Properties and Performance Standard of Phenolic Foam Insulation- Concentrated on Phenolic Foam Insulation for Construction, Proceeding of Spring Annual Conference Proceeding of the Architectural Institute of Korea, 39(1), 424-427
  4. JTBC, 인기 단열재서 발암물질 기준치 10배...정부는 '뒷짐'(2019). Retrieved March 18, 2020 from http://news.jtbc.joins.com/article/article.aspx?news_id=NB11885120
  5. Construction Technology News (2019). Retrieved March 18, 2020 from http://m.ctman.kr/news/17895
  6. Ministry of Environment (2017). Indoor air quality testing standards (실내공기질 공정시험기준)
  7. Korean Standards Association (2017). KS M 1998:2017 Determination of the emission rate of formaldehyde and volatile organic compounds in building interior products
  8. Living Environment Information Center, Retrieved March 18, 2020 from https://iaqinfo.nier.go.kr/means/building_materials_check.do
  9. Korea Construction Standards Center, National Construction Standard Specification (국가건설기준 표준시방서) KCS 41 42 00: 단열공사, 2018
  10. Ministry of Environment & National Insititute of Environmental Research, (2019). Manual for indoor air quality management (주택 실내공기질 관리를 위한 매뉴얼)
  11. Ministry of Environment, (2018). Recommended Standards for indoor air quality in new apartment house(실내공기질 관리법 시행규칙, 신축공동주택의 실내공기질 권고기준)
  12. Ministry of Land, Infrastructure and Transport (2018). Health-friendly housing construction standards (건강친화형 주택 건설기준)
  13. Jeon, J. Y. (2013). Indoor Air Quality Trends in Apartment Housing(공동주택의 실내공기질 동향), Korea Institute of Architectural Sustainable Environment and Building Systems, 7(3), 13-20
  14. Park, H. S., Kim, & Kim, H. T., & Hong, W. H. (2019). Measurement and Evaluation of Indoor Air Quality in Small-scale apartment in Daegu, Journal of the Architectural Institute of Korea, Structure and Construction, 35(10), 217-223
  15. Shim, H. S., & Choi, Y. J. (2008). Evaluation of the Indoor Air Quality in Occupied Apartment Unit after Remodeling, Journal of the Architectural Institute of Korea, Planning and Design Section, 24(12), 303-312