참고문헌
- Bode H, Seyfried CF. Mixing and detention time distribution in activated sludge tanks. Water Sci. Technol. 1985;17:197-208. https://doi.org/10.2166/wst.1985.0130
- Hynninen P, Luonsi A, Vuoriranta P. Reduction of pulp and paper industry effluent loading. Water Sci. Technol. 1986;18:109-125.
- Olivet D, Valls, Gordillo J, Freixo M, Sanchez A. Application of residence time distribution technique to the study of the hydrodynamic behaviour of a full-scale wastewater treatment plant plug-flow bioreactor. J. Chem. Technol. Biotechnol. 2005;80:425-432. https://doi.org/10.1002/jctb.1201
- Sanchez F, Viedma A, Kaiser A. Hydraulic characterization of an activated sludge reactor with recycling system by tracer experiment and analytical models. Water Res. 2016;101: 382-392. https://doi.org/10.1016/j.watres.2016.05.094
- Burrows L, Stokes A, West J, Forster C, Martin A. Evaluation of different analytical methods for tracer studies in aeration lanes of activated sludge plants. Water Res. 1999;33:367-374. https://doi.org/10.1016/S0043-1354(98)00249-8
- Karpinska AM, Bridgeman J. CFD-aided modelling of activated sludge systems-A critical review. Water Res. 2016;88:861-879. https://doi.org/10.1016/j.watres.2015.11.008
- Bai H, Stephenson A, Jimenez J, Jewell D, Gillis P. Modeling flow and residence time distribution in an industrial-scale reactor with a plunging jet inlet and optional agitation. Chem. Eng. Res. Des. 2008;86:1462-1476. https://doi.org/10.1016/j.cherd.2008.08.012
- Fu H, Ma L, Wang H. Experimental and numerical studies of residence time in SK direct contact heat exchanger for heat pump. Chem. Eng. Res. Des. 2018;135:94-102. https://doi.org/10.1016/j.cherd.2018.05.013
- Youssef Z, Ducept F, Bennaceur H, et al. Residence time distribution in a biomass pretreatment reactor: Experimentation and modeling. Chem. Eng. Res. Des. 2017;125:233-244. https://doi.org/10.1016/j.cherd.2017.07.015
- International Atomic Energy Agency. Radiotracer residence time distribution method for industrial and environmental applications. Vienna: IAEA; 2008.
- Jung SH, Jin JH, Kim JB. Radiotracer study on the efficiency of anaerobic sludge digester after cleaning up. J. Korean Soc. Environ. Eng. 2001;10:1641-1648.
- Othman N, Kamarudin S, Engku Chik E, Adnan M, Rosli M, Takriff M. Mathematical models of residence time distribution of integrated impeller mixing vessel using radiotracer. In: 6th International Conference on Process Systems Engineering (PSE ASIA), 25-27 June 2013; Kuala Lumpur.
- Othman N, Kamarudin SK. Radiotracer technology in mixing processes for industrial applications. Sci. World J. 2014;8:768604.
- Schraa O, Rieger L, Alex J. Development of a model for activated sludge aeration systems: Linking air supply, distribution, and demand. Water Sci. Technol. 2017;75:552-560. https://doi.org/10.2166/wst.2016.481
- Horan N, Parr J, Naylor P. Evaluation of tracers for the determination of the mixing characteristics of activated sludge reactors. Environ. Technol. 1991;12:603-608. https://doi.org/10.1080/09593339109385046
- Kasban H, Zahran O, Arafa H, El-Kordy M, Elaraby SM, El-Samie FA. Laboratory experiments and modeling for industrial radiotracer applications. Appl. Radiat. Isot. 2010;68:1049-1056. https://doi.org/10.1016/j.apradiso.2010.01.044
- Fogler HS. Essentials of chemical reaction engineering. Westford: Pearson Education; 2011.
- Levenspiel O. Chemical Reaction Engineering. 3rd ed. New York: John Wiley & Sons; 1999.
- Mjalli FS, Al-Asheh S, Alfadala H. Use of artificial neural network black-box modeling for the prediction of wastewater treatment plants performance. J. Environ. Manage. 2007;83:329-338. https://doi.org/10.1016/j.jenvman.2006.03.004
- Collivignarelli M, Bertanza G, Abba A, Damiani S. Troubleshooting in a full-scale wastewater treatment plant: What can be learnt from tracer tests. Int. J. Environ. Sci. Technol. 2018:1-12.
- Kjellstrand R, Mattsson A, Niklasson C, Taherzadeh MJ. Short circuiting in a denitrifying activated sludge tank. Water Sci. Technol. 2005;52:79-87.
- Khudenko B, Shpirt E. Hydrodynamic parameters of diffused air systems. Water Res. 1986;20:905-915. https://doi.org/10.1016/0043-1354(86)90180-6
- Knap M, Balbierz P. Modification of Rhodamine WT tracer tests procedure in activated sludge reactors. In: E3S Web of Conferences; 7 November 2017; EDP Sciences.
- Moreira R, Pinto AM, Mesnier R, Leclerc JP. Influence of inlet positions on the flow behavior inside a photoreactor using radiotracers and colored tracer investigations. Appl. Radiat. Isot. 2007;65:419-427. https://doi.org/10.1016/j.apradiso.2006.09.012
- Farooq M, Khan I, Din GU, Gul S, Palige J, Dobrowolski A. Radiotracer investigations of municipal sewage treatment stations. Nukleonika 2003;1:57-61.
- Gresch M, Braun D, Gujer W. Using reactive tracers to detect flow field anomalies in water treatment reactors. Water Res. 2011;45:1984-1994. https://doi.org/10.1016/j.watres.2010.11.017
- Fracz P, Wotzka D. Determination of hydrodynamic model based on tracer test performed in WWT plant in Kedzierzyn Kozle, Poland [dissertation]. Ponzan: Poznan Univ. of Technology; 2016.
- Kappeler J, Gujer W. Estimation of kinetic parameters of heterotrophic biomass under aerobic conditions and characterization of wastewater for activated sludge modelling. Water Sci. Technol. 1992;25:125-139. https://doi.org/10.2166/wst.1992.0118
- Mustafa IH, Ibrahim G, Elkamel A, Elahwany A. Heterogeneous modeling, identification and simulation of activated sludge processes. American J. Environ. Sci. 2009;5:352-363. https://doi.org/10.3844/ajessp.2009.352.363
- Raggul N, Saraswathi R. Microbial analysis and parametric optimization of activated sludge process in paper and pulp mill effluent plant: A case study. Desal. Water Treat. 2016;57: 12518-12535. https://doi.org/10.1080/19443994.2015.1054889
- Sarkar M, Sangal VK, Bhunia H, et al. Radiotracer investigation of a pulp and paper mill effluent treatment plant. Nukleonik 2017;62:289-294. https://doi.org/10.1515/nuka-2017-0042
- Sarkar M, Sangal VK, Sharma VK, et al. Radiotracer investigation and modeling of an activated sludge system in a pulp and paper industry. Appl. Radiat. Isot. 2017;130:270-275. https://doi.org/10.1016/j.apradiso.2017.10.016
- Teefy S. Tracer studies in water treatment facilities: A protocol and case studies. Denver (CO): American Water Works Association; 1996.
- Karches T, Buzas K. Investigation of residence time distribution and local mean age of fluid to determine dead-zones in Flow Field. Int. J. Comput. Meth. Exp. Measure. 2013;1:132-141. https://doi.org/10.2495/CMEM-V1-N2-132-141
- Biemer JJ. Antimicrobial susceptibility testing by the Kirby-Bauer disc diffusion method. Ann. Clin. Lab. Sci. 1973;3:135-140.
- Bonev B, Hooper J, Parisot J. Principles of assessing bacterial susceptibility to antibiotics using the agar diffusion method. J. Antimicrob. Chemoth. 2008;61:1295-1301. https://doi.org/10.1093/jac/dkn090
- Leclerc J, Schweich D, Bernard A, Detrez C. DTS: A Software package for flow simulation in reactors. Oil & Gas Science and Technology - Rev. IFP, 1995;50:641-656.
- APHA. Standard Methods for the Examination of Water and Wastewater 14 ed. APHA American Public Health Association, 1976.
- Abu-Reesh IM, Abu-Sharkh BF. Comparison of axial dispersion and tanks-in-series models for simulating the performance of enzyme reactors. Ind. Eng. Chem. Res. 2003;42:5495-5505. https://doi.org/10.1021/ie030131j
- Makinia J, Wells SA. Evaluation of empirical formulae for estimation of the longitudinal dispersion in activated sludge reactors. Water Res. 2005;39:1533-1542. https://doi.org/10.1016/j.watres.2005.01.028
- De Clercq J, Coen F, Vanderhaegen B, et al. Detailed spatio-temporal solids concentration profiling during batch settling of activated sludge using a radiotracer. Water Res. 2005;39: 2125-2135. https://doi.org/10.1016/j.watres.2005.03.023
피인용 문헌
- Identification and Localization of Hydrodynamic Anomalies in a Real Wastewater Treatment Plant by an Integrated Approach: RTD-CFD Analysis vol.7, pp.2, 2020, https://doi.org/10.1007/s40710-020-00437-4