Acknowledgement
The work presented in this paper was sponsored by the National Research Foundation of Korea (NRF) grants (No. 2018R1C1B5045037). The options, findings, and conclusions in this paper are those of the authors and do not necessarily represent those of the sponsors.
References
- National Research Institute of Cultural Heritage (2014), Conservation Management of Stone Cultural Heritage using Nondestructive Technology, National Research Institute of Cultural Heritage, Daejeon, Korea.
- Korea Institute of Construction Safety Technology (1998), Structural Safety Diagnosis for the Stone Pagoda of the Mireuk Temple Site, Jeonbuk.
- Yang, H.J., Lee, C.H., Choi, S.W. and Lee, M.S. (2006), "Petrological Characteristics and Provenance Presumption for Rock Properties of the Stone Pagoda in Mireuksaji Temple Site, Iksan, Korea", J. Geological Soc. Korea, 42(2), 293-306 (in Korean).
- Kim, S.D., Yi, J.E., Lee, D.S. and Lee, C.H. (2011), "Homogeneity Investigation of Replace Stone for Restoration of the Mireuksaji Stone Pagoda in Iksan, Korea", J. Conservation Sci., 27(2), 211-222 (in Korean).
- Zambas, C., Ioannidou, M. and Papanicolaou A. (1986), "The use of titanium reinforcement for the restoration of marble architectural members of Acropolis Monuments", Proceedings of IIC Congress, Bologna, 138-141. https://doi.org/10.1179/sic.1986.31.Supplement-1.138.
- Zambas, C. (1992), "Structural repairs to the monuments of the Acropolis - The Parthenon", Proceedings of the Institution of Civil Engineers, 166-176. https://doi.org/10.1680/icien.1992.21497.
- Kocaturk, T. and Erdogan, Y.S. (2016), "Earthquake behavior of M1 minaret of historical Sultan Ahmed Mosque (Blue Mosque)", Struct. Eng. Mech., 59(3), 539-558. https://doi.org/10.12989/sem.2016.59.3.539.
- Demir, A., Nohutcu, H., Ercan, E., Hokelekli, E. and Altintas, G. (2016), "Effect of model calibration on seismic behaviour of a historical mosque", Struct. Eng. Mech., 60(5), 749-760. https://doi.org/10.12989/sem.2016.60.5.749.
- Nohutcu, H, Hokelekli, E. Ercan, E., Demir A. and Altintas, G. (2017), "Collapse mechanism estimation of a historical slender minaret", Struct. Eng. Mech., 64(5), 653-660. https://doi.org/10.12989/sem.2017.64.5.653.
- Hamdy, G. A., Kamal, Osama A., El-Hariri, M. O. R. and El-Salakawy, T. S. (2018), "Nonlinear analysis of contemporary and historic masonry vaulted elements externally strengthened by FRP", Struct. Eng. Mech., 65(5), 611-619. https://doi.org/10.12989/sem.2018.65.5.611
- ACI Committee 318 (2014), Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary, American Concrete Institute (ACI), Farmington Hills, MI, USA.
- ASTM C78/C78M-18 (2018), Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading), ASTM International, West Conshohocken, PA, USA.
- ASTM C1194-18 (2018), Standard Test Method for Compressive Strength of Architectural Cast Stone, ASTM International, West Conshohocken, PA, USA.
- KS F 2519 (2015), Standard Test Method for Compressive Strength of Nature Building Stone, Korean Standard Association, Seoul, Korea.
- EN 1992-1-1 (2004), Eurocode 2: Design of concrete structures - Part 1-1: General Rules and Rules for Buildings, European Committee for Standardization.
- ASTM E8/E8M-16a (2016), Standard Test Methods for Tension Testing of Metallic Materials, ASTM International, West Conshohocken, PA, USA.
- Selwitz, C. (1992), Epoxy Resins in Stone Conservation, Research in Conservation 7, Getty Conservation Institute, Marina del Rey, CA, USA.