References
- Cambra-Lopez, M., Aarnink, A. J. A., Zhao, Y., Calvet, S., & Torres, A. G., 2010, Airborne particulate matter from livestock production systems: A review of an air pollution problem. Environmental Pollution, 158(1), 1-17. https://doi.org/10.1016/j.envpol.2009.07.011
- CIGR, 1994, Airborne environment in animal housing. Concentrations in and emissions from farm buildings. Working Groupd Report Series No 94.1. Rennes.
- Dee, S., Otake, S., Oliveira, S., & Deen, J., 2009, Evidence of long distance airborne transport of porcine reproductive and respiratory syndrome virus and Mycoplasma hyopneumoniae. Veterinary Research, 40(4), 39. https://doi.org/10.1051/vetres/2009022
- Donham, K. J., 1991, Association of environmental air contaminants with disease and productivity in swine. American Journal of Veterinary Research, 52(10), 1723-1730.
- Donham, K., & Reynolds, S., 1995, Respiratory dysfunction in swine production facility workers: Dose-response relationships of environmental exposures and pulmonary function. American Journal of Industrial Medicine, 27, 405-418. https://doi.org/10.1002/ajim.4700270309
- Donham, K. J., 2000, The concentration of swine production: Effects on swine health, productivity, human health, and the environment. Vet. Clinics North America Food Animal Practice, 16(3), 559-598.
- Ellen, H. H., Bottcher, R. W., von Wachenfelt, E., & Takai, H., 2000, Dust levels and control methods in poultry houses. Journal of Agricultural Safety and Health, 6(4), 275-282. https://doi.org/10.13031/2013.1910
- Gustafsson, G., 1997, Investigations of factors affecting air pollutants in animal houses. Annals of Agriculture and Environmental Medicine, 4(2), 203-215.
- Gustafsson, G., 1999, Factors affecting the Release and Concentration of Dust in Pig Houses. Journal of AgricuItural Engineering Research, 74(4), 379-390.
- Hinz, T., & Linke, S.,1998, A Comprehensive Experimental Study of Airborne Pollutants in and Emissions from Livestock Buildings. Part 2: Results. Journal of Agricultural Engineering Research, 70(1), 119-129. https://doi.org/10.1006/jaer.1998.0282
- ISO, 1995, ISO 7708. Air Quality - Particle Size Fraction Definitions for Health-related Sampling.
- Iversen, M., KirychuK S., Drost, H., & Jacobson, L., 2000, Human health effects of dust exposure in animal confinement buildings. Journal of Agricultural Safety and Health, 6(4), 283-288. https://doi.org/10.13031/2013.1911
- Mitchell, B. W., Buhr, R. J., Berrang, M. E., Bailey, J. S., & Cox, N. A., 2002, Reducing airborne pathogens, dust and Salmonella transmission in experimental hatching cabinets using an electrostatic space charge system. Poultry Science, 81, 49-55.
- Otake, S., Dee, S., Corzo, C., Loiveira, S., & Deen, J., 2010, Long-distance airborne transport of infectious PRRSV and Mycoplasma hyopneumoniae from a swine population infected with muItiple viral variants. Veterinary Microbiology, 145, 198-208. https://doi.org/10.1016/j.vetmic.2010.03.028
- Qi, R, Manbeck, H. B., & Maghirang, R. G., 1992, Dust net generation rate in a poultry layer house. Transactions of the ASAE, 35(5), 1639-1645. https://doi.org/10.13031/2013.28778
- Radon, K, Weber, C., Iversen, M., Danuser, B., Pedersen, S., & Nowak, D., 2001, Exposure assessment and lung function in pig and poultry farmers Exposure assessment and lung function in pig and poultry farmers. Occupational and Environmental Medicine, 58, 405-410.
- Redwine, J. S., Lecey, R. E., Mukhtar, S., & Carey, J. B., 2002, Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas. Transactions of the ASAE, 45(4), 1101-1109.
- Reynolds, S. J., Donham, K. J., Whitten, P., Merchant, J. A, Burmeister, L. F., & Popendorf, W. J., 1996, Longitudinal evaluation of dose-response relationships for environmental exposures and pulmonary function in swine production workers. American Journal of Industrial Medicine, 29(1), 33-40. https://doi.org/10.1002/(SICI)1097-0274(199601)29:1<33::AID-AJIM5>3.0.CO;2-#
- Rosentrater, K., 2004, Laboratory analysis of an electrostatic dust collection system. In Agricultural Engineering International: the CIGR Journal of Scientific Research and Development (p. Manuscript BC 03 008).
- Robertson, J. F., 1992, Dust and ammonia in pig buildings. In Farm building progress (pp. 19-24). Aberdeen.
- Seedorf, J., 1997, Human health and dust related endotoxin concentrations in livestock buildings. In European AgricuItural Engineers Conference (pp. 733-740.).
- US EPA, 2001, Code of Federal Regulations. Appendix J to Pato 50 - Reference Method for the Determination of Particulate Matter as PM10 in the Atomsphere.
- Kwon, K, Lee, I. & Ha, T., 2016, Identification of key factors for dust generation in a nursery pig house and evaluation of dust reduction efficiency using a CFD technique. Biosystems Engineering, 151, 28-52. https://doi.org/10.1016/j.biosystemseng.2016.08.020
- Takai, H., Pedersen, S., Johnsen, J. O., Metz, J. H. M., Koerkamp, P. W. G. G., Unek, G. H., Phillips, V. R, Holden, M. R, Sneath, R. W., Short, J. L, White, R. P., Hartung, J., Seedorf, J., Schroder, M., Linkert, K. H., & Wathes, C. M., 1998, Concentrations and emissions of airborne endotoxins and microorganisms in livestock buildings in Northern Europe. Journal of Agricultural Engineering Research, 70(1), 59-77. https://doi.org/10.1006/jaer.1997.0280
- Vogelzang, P. F. J., van der Gulden, J. W. J., Folgering, H., Kolk J. J., Heederik, D., Preller, L, Tielen, M J. M., & Schyck, C. P., 1998, Endotoxin exposure as a major determinant of lung function decline in pig farmers. American Journal of Respiratory and Critical Care Medicine, 157(1), 15-18. https://doi.org/10.1164/ajrccm.157.1.9703087
- Vucemilo, M., Matkovic, K, Vinkovic, B., Macan, J., Varnai, V. M., Prester, L, Granic, K, & Orct, T., 2008, Effect of microclimate on the airborne dust and endotoxin concentration in a broiler house. Czech Journal of Animal Science, 53(2), 83-89. https://doi.org/10.17221/329-cjas
- Wathes, C. M., Sneath, R., & Philips, V. R., 2004, Particulate emissions from intensively houses livestock: sources and effects. In Engineering the Future. Leuven: AgEng.
- Wing, S., Horton, R. A., Marshall, S. W., Thu, K, Tajik, M., Schinasi, L., & Schiffman, S. S., 2008, Air pollution and odor in communities near industrial swine operations. Environmental Health Perspectives, 116(10), 1362-1368. https://doi.org/10.1289/ehp.11250
- Zucker, B. A., Trojan, S., & Muller, W., 2000, Airborne gram-negative bacterial flora in animal houses. Journal of Veterinary Medicine, Series B, 47(1), 37-46. https://doi.org/10.1046/j.1439-0450.2000.00308.x