A new equation based on PGA to provide sufficient separation distance between two irregular buildings in plan

  • Loghmani, Adel (Civil Engineering Department, Semnan Branch, Islamic Azad University) ;
  • Mortezaei, Alireza (Seismic Geotechnical and High Performance Concrete Research Centre, Civil Engineering Department, Semnan Branch, Islamic Azad University) ;
  • Hemmati, Ali (Seismic Geotechnical and High Performance Concrete Research Centre, Civil Engineering Department, Semnan Branch, Islamic Azad University)
  • 투고 : 2019.10.10
  • 심사 : 2019.12.26
  • 발행 : 2020.05.25

초록

Past earthquakes experience shows that serious damage or collapse of buildings have dramatically accrued when sufficient separation distance has not been provided between two adjacent structures. The majority of past studies related to the pounding topic indicate that obtaining the gap size between two buildings is able to prevent collision and impact hazards during seismic excitations. Considering minimization of building collisions, some relationships have been suggested to determine the separation distance between adjacent buildings. Commonly, peak lateral displacement, fundamental period and natural damping as well as structural height of two adjacent buildings are numerically considered to determine the critical distance. Hence, the aim of present study is to focus on all mentioned parameters and also utilizing the main characteristic of earthquake record i.e. PGA to examine the lateral displacement of irregular structures close to each other and also estimate the sufficient separation distance between them. Increasing and decreasing the separation distance is inherently caused economical problems due to the land ownership from a legal perspective and pounding hazard as well. Therefore, a new equation is proposed to determine the optimum critical distance. The accuracy of the proposed formula is validated by different models and various earthquake records.

키워드

참고문헌

  1. Anagnostopoulos, S.A. (1998), "Pounding of buildings in series during earthquakes." Earthq. Eng. Struct. Dyn., 16(3), 443-456. https://doi.org/10.1002/eqe.4290160311
  2. Building and Housing Research Center (2017), "Iranian code of practice for seismic resistant design of buildings (Standard No. 2800 - 4th edition)" Permanent Committee of Revising the Code of Practice for Seismic Resistant Design of Buildings, BHRC.
  3. Dogruel, S. (2005), "Application of genetic algorithms for optimal aseismic design of passively damped adjacent structures", Individual Study, State University of New York at Buffalo, U.S.A.
  4. Falborski, T., Jankowski, R. and Kwiecien, A. (2012), "Experimental study on polymer mass used to repair damaged structures", Key Eng. Mat., 488, 347-350. Trans Tech Publications. https://doi.org/10.4028/www.scientific.net/KEM.488-489.347
  5. Favvata, M.J., Karayannis, C.G. and Liolios, A.A. (2009), "Influence of exterior joint effect on the inter-story pounding interaction of structures", Struct. Eng. Mech., 33(2), 113-136. https://doi.org/10.12989/sem.2009.33.2.113.
  6. Filiatrault, A., Wagner, P. and Cherry, S. (1995), "Analytical prediction of experimental building pounding", Earthq. Eng. Struct. Dyn., 24(8), 1131-1154. https://doi.org/10.1002/eqe.4290240807.
  7. Garcia, D.L. (2004), "Separation between adjacent non-linear structures for prevention of seismic pounding", In the Proceedings of 13th World Conference on Earthquake Engineering, Vancouver, Canada.
  8. Hao, H. and Shen, J. (2001), "Estimation of relative displacement of two adjacent asymmetric structures", Earthq. Eng. Struct. Dyn., 30(1), 81-96. https://doi.org/10.1002/1096-9845(200101)30:1%3C81::AID-EQE997%3E3.0.CO;2-E.
  9. International Code Council (2003), International Building Code (IBC), Birmingham, U.S.A.
  10. Jankowski, R. and Mahmoud, S. (2015), "Earthquake-Induced Structural Pounding", Springer, Basel, Switzerland.
  11. Jeng, V. and Tzeng, W.L. (2000), "Assessment of seismic pounding hazard for Taipei City", Eng. Struct., 22(5), 459-471. https://doi.org/10.1016/S0141-0296(98)00123-0
  12. Karayannis, C.G. and Favvata, M.J. (2005), "Earthquake-induced interaction between adjacent reinforced concrete structures with non-equal heights", Earthq. Eng. Struct. Dyn., 34(1), 1-20. https://doi.org/10.1002/eqe.398.
  13. Karayannis, C.G. and Naoum, M.C. (2018), "Torsional behavior of multistory RC frame structures due to asymmetric seismic interaction", Eng. Struct., 163, 93-111. https://doi.org/10.1016/j.engstruct.2018.02.038.
  14. Kasai, K. and Maison, B.F. (1997), "Building pounding damage during the 1989 Loma Prieta earthquake", Eng. Struct., 19(3), 195-207. https://doi.org/10.1016/S0141-0296(96)00082-X.
  15. Khatami, S.M., Naderpour, H., Barros, R.C. and Jankowski, R. (2019), "Verification of formulas for periods of adjacent buildings used to assess minimum separation gap preventing structural pounding during earthquakes", Advan. Civil Eng., https://doi.org/10.1155/2019/9714939.
  16. Komodromos, P. (2008), "Simulation of the earthquake-induced pounding of seismically isolated buildings", Comput. Struct., 86(7-8), 618-626. https://doi.org/10.1016/j.compstruc.2007.08.001.
  17. Komodromos, P., Polycarpou, P.C., Papaloizou, L. and Phocas, M.C. (2007), "Response of seismically isolated buildings considering poundings", Earthq. Eng. Struct. Dyn., 36(12), 1605-1622. https://doi.org/10.1002/eqe.692.
  18. Lopez-Garcia, D. and Soong, T.T. (2009), "Evaluation of current criteria in predicting the separation necessary to prevent seismic pounding between nonlinear hysteretic structural systems", Eng. Struct., 31(5), 1217-1229. https://doi.org/10.1016/j.engstruct.2009.01.016.
  19. Mohsenian, V. and Mortezaei, A. (2018), "Evaluation of seismic reliability and multi level response reduction factor (R-factor) for eccentric braced frames with vertical links", Earthq. Struct., 14(6), 537-549. https://doi.org/10.12989/eas.2018.14.6.537.
  20. Mortezaei, A. and Ronagh, H.R. (2013), "Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step", Nat. Haz. Earth Syst. Sci., 13(6), 1579-1593. https://doi.org/10.5194/nhess-13-1579-2013.
  21. Naderpour, H., Barros, R.C. and Khatami, S.M. (2017), "Prediction of critical distance between two MDOF systems subjected to seismic excitation in terms of artificial neural networks", Periodica Polytechnica Civil Eng., 61(3), 516-529. https://doi.org/10.3311/PPci.9618.
  22. NBC (2003), "National building code", Technical Standard of Building E.030. Earthquake resistant design. Ministry of housing, Peru.
  23. Penzien, J. (1997), "Evaluation of building separation distance required to prevent pounding during strong earthquakes", Earthq. Eng. Struct. Dyn., 26(8), 849-858. https://doi.org/10.1002/(SICI)10969845(199708)26:8%3C849::AID-EQE680%3E3.0.CO;2-M
  24. Polycarpou, P.C., Komodromos, P. and Polycarpou, A.C. (2013), "A nonlinear impact model for simulating the use of rubber shock absorbers for mitigating the effects of structural pounding during earthquakes", Earthq. Eng. Struct. Dyn., 42(1), 81-100. https://doi.org/10.1002/eqe.2194.
  25. Pratesi, F., Sorace, S. and Terenzi, G. (2014), "Analysis and mitigation of seismic pounding of a slender R/C bell tower", Eng. Struct., 71, 23-34. https://doi.org/10.1016/j.engstruct.2014.04.006.
  26. Standard, B. (2005), "Eurocode 8: Design of structures for earthquake resistance Part 1".
  27. Valles, R.E. and Reinhorn, A.M. (1997), "Evaluation, prevention and mitigation of pounding effects in buildings structures", National Center of Earthquake Engineering Research, Technical Report.
  28. Warnotte, V. (2008), "Mitigation of pounding between adjacent buildings in earthquake situation", Ph. Dissertation, University of Liege.
  29. Yang, Z., Xu, Y.L. and Lu, X.L. (2003), "Experimental seismic study of adjacent buildings with fluid dampers", J. Struct. Eng., 129(2), 197-205. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:2(197).