DOI QR코드

DOI QR Code

An Evaluation of Indoor Thermal Environment for Zero-Carbon Green Home according to the Operation Conditions in Summer

제로카본 그린홈의 여름철 운영조건에 따른 실내 열환경 평가

  • Yu, Jung yeon (Department of Living and Built Environment Research, Korea Institute of Civil Engineering and Building Technology) ;
  • Cho, Dong woo (Department of Living and Built Environment Research, Korea Institute of Civil Engineering and Building Technology) ;
  • Kim, Kee Han (Department of Architectural Engineering, University of Ulsan)
  • 유정연 (한국건설기술연구원, 국민생활연구본부) ;
  • 조동우 (한국건설기술연구원, 국민생활연구본부) ;
  • 김기한 (울산대학교 건축공학부)
  • Received : 2020.03.24
  • Accepted : 2020.04.23
  • Published : 2020.04.30

Abstract

The Korean government has a plan to mandate zero-energy buildings in 2020 for public and 2025 for private buildings. In order to design a zero-energy building, insulation and airtightness, which are the most basic elements of passive house technology, are required, and the government has been accomplished this through step-by-step strengthening of related standards. In passive house with high thermal insulation and airtightness performance, the heat introduced into the building through solar radiation can be stored for a long time to keep the inside warm during winter. On the other hand, during summer, heat introduced into the building cannot be easily released to outside, so it is necessary to actively block solar radiation and high temperature outdoor air to prevent an increase of indoor temperature. Therefore, this study aims to derive an appropriate operation condition of passive house to maintain the indoor temperature at an suitable level according to the ventilation methods and solar shading conditions. As a result, under the conditions that the outdoor temperature was 28℃ or less, the ventilation using a heat recovery ventilation system at daytime and natural ventilation at nighttime were selected for the most appropriate operation method. In addition, in the case of solar shading, it was found that blocking solar radiation at daytime using the blind and open the blind at nighttime to ensure natural ventilation were selected for the most appropriate solar shading condition.

Keywords

References

  1. Ministry of Land, Infrastructure and Transport, Green Buildings Construction Support Act, 2020.
  2. Ministry of Land, Infrastructure and Transport, Builidng Energy-saving Design Standard, 2018.
  3. Oh, D. S., The insulation and airtightness of passive house, The Magazine of Korean solar Energy Society, Vol. 16, No. 1, pp. 23-32, 2018.
  4. Park, K. T., A Study on the Characteristics of Ventilation Performance of Passive House, The Society of Air-conditioning and Refrigerating Engineers of Korea, Vol. 41, No. 4, pp. 38-46, 2012.
  5. Lee, H. S., Kim, S. H., and Choi, J. M., A Study on the Natural Cooling Effect by Ventilation Control Mode of Window at School Classroom, Journal of the Korean Solar Energy Society, Vol. 38, No. 4, pp. 67-76, 2018. https://doi.org/10.7836/KSES.2018.38.4.067
  6. Cho, J. K., Hong, M. H., and Yoo, C. W., Effective Openable Area and Position of Windows for High-rise Residences with (Single-sided) Natural Ventilation, Journal of the Architectural Institute of Korea Planning & Design, Vol. 26, No. 8, pp. 247-254, 2010.
  7. Yee, J. J. and Kim, S.K., Study on an Energy-efficient Outdoor Air Supply Operation Control Method of Apartment Heat Recovery Ventilation System, Journal of the Architectural Institute of Korea Planning & Design, Vol. 25, No. 6, pp. 295-302, 2009.
  8. Lee, Y. J., Leigh, S. B., and Lee, K. H., A Study on the Operational Strategy for Hybrid Ventilation System in Apartment Unit Focused on Indoor Air Quality, Journal of the Korea Institute of Ecological Architecture and Environment, Vol. 4, No. 3, pp. 203-210, 2004.
  9. Cho, D. W., Yu, J. Y., Jung, J. W., and Paik, J. H., Infrastructure Establishment and Practical Application for Zero Carbon Green Home, Korea Institute of Civil Engineering and Building Technology, 2014.
  10. Cho, D. W., The Study on the Operation for the Energy Consumption Certificate, Korea Institute of Civil Engineering and Building Technology, 2012.