The authors address the problem of ameliorating or updating existing educational buildings. This building typology is quite sensitive to social and media pressure, mainly when accidents have occurred nearby. When a building is classified as unsatisfactory, the current code requirements oblige one to re-design the building with significant penalty factors in the resistance values. Often the only solution is to destroy the existing facility and to build a new one. When attempting to preserve the existing building, higher levels of safety are demanded by the society and this can only be achieved by innovative system architectures. The authors propose and discuss a prototype that can be easily adopted to retrofit small educational buildings as the ones common in small municipalities. The higher performance is pursued by a special design of the control scheme, with new control devices and special control laws.

Keywords

References

  1. Casciati, S. (2018), "Computational issues toward the amelioration and retrofit of educational buildings", Proceedings of the 10th International Conference on Engineering Computational Technology, Sitges, Spain.
  2. Casciati, F. and Casciati, S. (2018), "Amelioration and retrofitting of educational buildings", Earthq. Eng. Eng. Vib., 17, 47-51. https://doi.org/10.1007/s11803-018-0424-2
  3. Casciati, F. and Faravelli, L. (1991), Fragility Analysis of Complex Structural Systems, Research Studies Press, Taunton, UK.
  4. Casciati, S., Chassiakos, A.G. and Masri, S.F. (2014), "Toward a paradigm for civil structural control", Smart Struct. Syst., Int. J., 14(5), 981-1004. https://doi.org/10.12989/sss.2014.14.5.981
  5. Erhorn-Kluttig, H., Erhorn, H., Kempe, S., Hofl, E.C., Gorres, J. and Thomsen, K.E. (2016), "EU Project "School of the Future"- Refurbishment of School Buildings Toward Zero Emission with High-Performance Indoor Environment", ASHRAE Transactions, 122: Part 1.
  6. Fornero, G. (2006), Il pensiero contemporaneo: dall'Ermeneutica alla Filosofia Analitica, Istituto Geografico De Agostini, Novara. [In Italian]
  7. Hancilar, U., Cakti, E., Erdik, M., Franco, G.E. and Deodatis, G. (2014), "Earthquake vulnerability of school buildings: Probabilistic structural fragility analyses", Soil Dyn. Earthq. Eng., 67, 169-178. https://doi.org/10.1016/j.soildyn.2014.09.005
  8. Kolovsky, M.Z. (1999), Nonlinear Dynamics of Active and Passive Systems of Vibration Protection, Springer, Vienna, Austria.
  9. Martelli, A. (2019), Personal Communication.
  10. Myrtle, R.C., Masri, S.F., Nigbor, R.L. and Caffreya, J.P. (2005), "Classification and prioritization of essential systems in hospitals under extreme events", Earthq. Spectra, 21(3), 779-802. https://doi.org/10.1193/1.1988338
  11. Shrestha, H.D., Pribadi, K.S., Kusumastuti, D. and Lim, E. (2008), Manual on "Retrofitting of Existing Vulnerable School Buildings - Assessment to Retrofitting Part I, Save the Children.
  12. Shrestha, H.D., Pribadi, K.S., Kusumastuti, D. and Lim, E. (2009), Manual on "Retrofitting of Existing Vulnerable School Buildings - Assessment to Retrofitting Part II, Save the Children.
  13. Smyth, A.W., Deodatis, G., Franco, G., He, Y. and Gurvich, T. (2004), "Evaluating earth-quake retrofitting measures for schools: a demonstration cost-benefit analysis. Ad hoc experts' group meeting on earthquake safety in schools", OECD Program on Educational Building and GeoHazards International, Paris, France.
  14. Syrmakezis, C.A., Mavrouli, O.A. and Antonopoulos, A.K. (2006), "Rehabilitation of hospital buildings using passive control systems", Smart Struct. Syst., Int. J., 2(4), 305-312. https://doi.org/10.12989/sss.2006.2.4.305
  15. Tesfamariam, S. and Wang, Y. (2012), "Risk-based seismic retrofit prioritization of reinforced concrete civic infrastructure: case study for State of Oregon schools and emergency facilities", Natural Hazards Review, 13(3), 188-195. https://doi.org/10.1061/(ASCE)NH.1527-6996.0000060