Wind-induced responses and dynamic characteristics of a super-tall building under a typhoon event

  • Hua, X.G. (Key Laboratory for Wind and Bridge Engineering of Hunan Province, College of Civil Engineering, Hunan University) ;
  • Xu, K. (Key Laboratory for Wind and Bridge Engineering of Hunan Province, College of Civil Engineering, Hunan University) ;
  • Wang, Y.W. (Department of Civil and Structural Engineering, Hong Kong Polytechnic University) ;
  • Wen, Q. (Hunan Provincial Key Laboratory of Structural Engineering for Wind Resistant and Vibration Control, Hunan University of Science and Technology) ;
  • Chen, Z.Q. (Key Laboratory for Wind and Bridge Engineering of Hunan Province, College of Civil Engineering, Hunan University)
  • 투고 : 2018.12.01
  • 심사 : 2019.10.13
  • 발행 : 2020.01.25

초록

Wind measurements were made on the Canton Tower at a height of 461 m above ground during the Typhoon Vincente, the wind-induced accelerations and displacements of the tower were recorded as well. Comparisons of measured wind parameters at upper level of atmospheric boundary layer with those adopted in wind tunnel testing were presented. The measured turbulence intensity can be smaller than the design value, indicating that the wind tunnel testing may underestimate the crosswind structural responses for certain lock-in velocity range of vortex shedding. Analyses of peak factors and power spectral density for acceleration response shows that the crosswind responses are a combination of gust-induced buffeting and vortex-induced vibrations in the certain range of wind directions. The identified modal frequencies and mode shapes from acceleration data are found to be in good agreement with existing experimental results and the prediction from the finite element model. The damping ratios increase with amplitude of vibration or equivalently wind velocity which may be attributed to aerodynamic damping. In addition, the natural frequencies determined from the measured displacement are very close to those determined from the acceleration data for the first two modes. Finally, the relation between displacement responses and wind speed/direction was investigated.

키워드

과제정보

연구 과제 주관 기관 : National Science Foundation of China

참고문헌

  1. AIJ 1996 (1996), AIJ Recommendations for Loads on Buildings, Architectural Institute of Japan; Tokyo, Japan.
  2. ASCE7-05 (2006), Minimum Design Loads for Buildings and Other Structures-ASCE, American Society of Civil Engineers (ASCE); New York, USA.
  3. Au, S.K., Zhang, F.L. and To, P. (2012), "Field observations on modal properties of two tall buildings under strong wind", J. Wind Eng. Ind. Aerod., 101, 12-23. https://doi.org/10.1016/j.jweia.2011.12.002
  4. Ballio, G., Maberini, F. and Solari, G. (1992), "A 60-year old, 100m high steel tower: limit states under wind action", J. Wind Eng. Ind. Aerod., 43(1-3), 2089-2100. https://doi.org/10.1016/0167-6105(92)90639-R
  5. Banks, D. and Meroney, R.N. (2001), "The applicability of quasisteady theory to pressure statistics beneath roof-top vortices", J. Wind Eng. Ind. Aerod., 89, 569-598. https://doi.org/10.1016/S0167-6105(00)00092-1
  6. Bashor R. Bobby S., Kijewski-Correa T. and Kareem A. (2012), "Full-scale performance evaluation of tall buildings under wind", J. Wind Eng. Ind. Aerod., 104, 88-97. https://doi.org/10.1016/j.jweia.2012.04.007
  7. Bortoluzzi, D., Casciati, S., Elia, L. and Faravelli, L. (2015), "Design of a TMD solution to mitigate wind-induced local vibration in an existing timber footbridge", Smart Struct. Syst., Int. J., 16(3), 459-478. https://doi.org/10.12989/sss.2015.16.3.459
  8. Brownjohn, J.M. (2007), "Structural health monitoring of civil structures", Philosoph. Transact.: Series A: Mathe., Phys., Eng. Sci., 365(1851), 589-622.
  9. Brownjohn, J.M. and Pan, T.C. (2008), "Identifying loading and response mechanisms from ten years performance monitoring of a tall building", J Perform. Constr. Fac.-ASCE, 22, 24-34. https://dx.doi.org/10.1061/(ASCE)0887-3828(2008)22:1(24)
  10. Campbells, S., Kwok, K.C.S. and Hitchock, P.A. (2005), "Dynamic characteristics and wind-induced response of two high-rise residential buildings during typhoons", J. Wind Eng. Ind. Aerod., 93(6), 461-482. https://dx.doi.org/10.1016/j.jweia.2005.03.005
  11. Cao, S.Y., Tamura, Y., Kikuchi, N., Saito, M., Nakayama, I. and Matsuzaki, Y. (2009). "Wind characteristics of a strong typhoon", J. Wind Eng. Ind. Aerod., 97(1), 11-21. https://doi.org/10.1016/j.jweia.2008.10.002
  12. Caracoglia, L. and Jones, N.P. (2009), "Analysis of full-scale wind and pressure measurements on a low-rise building", Eng. Struct., 97(5-6), 157-173. https://dx.doi.org/10.1016/j.jweia.2009.06.001
  13. Chen, W.H., Lu, Z.R. and Lin, W. (2011), "Theoretical and experimental modal analysis of the Guangzhou New TV Tower". Eng. Struct., 33(12), 3628-3646. https://doi.org/10.1016/j.engstruct.2011.07.028
  14. Choi, C.K. (1983), Wind loading in Hong Kong: commentary on the code of practice on wind effects Hong Kong, Hong Kong Institute of Engineers, Hong Kong, China.
  15. Davenport, A.G. (1962), "The Spectrum of horizontal gustiness near the ground in high winds", Q. J. Roy. Meteor. Soc., 87, 194-211. https://doi.org/10.1002/qj.49708837618
  16. Davenport, A.G. (1975), "Perspectives on the full-scale measurement of wind effect", J. Wind Eng. Ind. Aerod., 1(1), 23-54. https://doi.org/10.1016/0167-6105(75)90005-7
  17. Ellis, B.R. (1996), "Full-scale measurements of dynamic characteristics of buildings in UK", J. Wind Eng. Ind. Aerod., 59(2-3), 365-382. https://doi.org/10.1016/0167-6105(96)00017-7
  18. Fu, J.Y., Li, Q.S. and Wu, J.R. (2008), "Field measurements of boundary layer wind characteristics and wind-induced responses of super-tall buildings", J. Wind Eng. Ind. Aerod., 96(8-9), 1332-1358. https://doi.org/10.1016/j.jweia.2008.03.004
  19. GB 50009 (2012), Load Code for the design of building structures, Beijing, Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD); Beijing, China.
  20. Guo, Y.L., Kareem, A., Ni, Y.Q. and Liao, W.Y. (2012), "Performance evaluation of Canton Tower under winds based on full-scale data", J. Wind Eng. Ind. Aerod., 104-106, 116-128. https://doi.org/10.1016/j.jweia.2012.04.001
  21. Harris, R.I. (1968), "On the spectrum and auto-correlation function of gustiness in high winds", An E.R.A. technical report no.5273; Electrical Research Association.
  22. He, Y., Han, X., Li, Q.S., Zhu, H.P. and He, Y. (2018), "Monitoring of wind effects on 600 m high Ping-An Finance Center during Typhoon Haima", Eng. Struct., 167, 308-326. https://dx.doi.org/10.1016/j.engstruct.2018.04.021
  23. Holmes, J.D. (2001), Wind Loadings of Structures, Spon Press, Taylor & Francis Group, Australia.
  24. Hong Kong Observatory (2012), An overview of tropical cyclones in July 2012; Hong Kong Observatory, Hong Kong, China. http://gb.weather.gov.hk/informtc/tc2012/tc1207c_uc.htm
  25. Irwin, P.A. (2008), "Bluff body aerodynamics in wind engineering", J. Wind Eng. Ind. Aerod., 96(6-7), 701-702. https://doi.org/10.1016/j.jweia.2007.06.008
  26. Irwin, P.A. (2009), "Wind engineering challenges of the new generation of super-tall buildings", J. Wind Eng. Ind. Aerod., 97(7-8), 328-334. https://doi.org/10.1016/j.jweia.2009.05.001
  27. Ishizaki, H. (1983), "Wind profiles, turbulence intensities and gust factors for design in typhoon-prone regions", J. Wind Eng. Ind. Aerod., 13(1-3), 55-66. https://doi.org/10.1016/0167-6105(83)90128-9
  28. ISO6897 (1984), Guidelines for the evaluation of the response of occupants of fixed structures, especially buildings and off-shore structures, to low-frequency horizontal motion (0.063 to 1Hz), ISO.
  29. Jeary, A.P. (1992), "Establishing non-linear damping characteristics of structures from non-stationary time-histories", The Structural Engineer, 70(4), 62-66. http://www.istructe.org/webtest/files/8b/8bb58868-a1b8-4dc7-892a-f258b311ee53.pdf
  30. Kareem, A. and Gurley, K. (1996), "Damping in structures: its evaluation and treatment of uncertainty", J. Wind Eng. Ind. Aerod., 59(2-3), 131-157. https://doi.org/10.1016/0167-6105(96)00004-9
  31. Kareem, A., Kijewski, T. and Tamura, Y. (1999), "Mitigation of motions of tall buildings with specific examples of recent applications", Wind Struct., Int. J., 2(3), 201-251. https://doi.org/10.12989/was.1999.2.3.201
  32. Kijewski-Correa, T., Kilpatrick, J. and Kareem, A. (2006), "Validating wind-induced response of tall buildings: Synopsis of the chicago full-scale monitoring program", J. Struct. Eng., 132(10), 1509-1523. https://dx.doi.org/10.1061/(ASCE)0733-9445(2006)132:10(1509)
  33. Li, Q.S., Xiao, Y.Q., Wong, C.K. and Jeary, A.P. (2004), "Field measurements of typhoon effects on a super tall building", Eng. Struct., 26(2), 233-244. https://doi.org/10.1016/j.engstruct.2003.09.013
  34. Li, Q.S., Xiao, Y.Q., Wu, J.R., Fu, J.Y. and Li, Z.N. (2008), "Typhoon effects on super-tall buildings", J. Sound Vib., 313(3-5), 581-602. https://doi.org/10.1016/j.jsv.2007.11.059
  35. Lu, Z., Wang, D.C., Masri, S.F. and Lu, X.L. (2016), "An experimental study of vibration control of wind-excited high-rise buildings using particle tuned mass dampers", Smart Struct. Syst., Int. J., 18(1), 93-115. https://doi.org/10.12989/sss.2016.18.1.093
  36. Ni, Y.Q., Xia, Y., Liao, W.Y. and Ko, J.M. (2009), "Technology innovation in developing the structural health monitoring system for Guangzhou New TV Tower", Struct. Control Hlth., 16(1), 73-98. https://doi.org/10.1002/stc.303
  37. Porterfield, M. and Jones, N.P. (2001), "Development of a field measurement instrumentation system for low-rise construction", Wind Struct., Int. J., 4(3), 247-260. https://doi.org/10.12989/was.2001.4.3.247
  38. Simiu, E. and Scanlan, R.H. (1996), Wind Effects on Structures (Third Edition), A Wiley-inter science publication, New York, USA.
  39. Siringoringo, D.M. and Fujino, Y. (2017), "Wind-induced responses and dynamic characteristics of an asymmetrical baseisolated building observed during typhoons", J. Wind Eng. Ind. Aerod., 167, 183-197. https://doi.org/10.1016/j.jweia.2017.04.020
  40. Solari, G. and Piccardo, G. (2001), "Probabilistic 3-D turbulence for gust buffeting of structures", Probabil. Eng. Mech., 16(1), 73-86. https://doi.org/10.1016/S0266-8920(00)00010-2
  41. Sun, H.X., Zuo, L., Wang, X.Y., Peng, J. and Wang, W.X. (2019), "Exact $H_2$ optimal solutions to inerter-based isolation systems for building structures", Struct. Control Hlth., 26(6), 1-21. https://doi.org/10.1002/stc.2357
  42. Tamura, Y. and Suganuma, S. (1996), "Evaluation of amplitudedependent damping and natural frequency of buildings during strong winds", J. Wind Eng. Ind. Aerod., 59(2-3), 115-130. https://doi.org/10.1016/0167-6105(96)00003-7
  43. Tamura, Y., Yoshida, A., Ishibashi, R., Matsui, M. and Pagnini, L.C. (2002), "Measurement of wind-induced response of buildings using RTK-GPS and integrity monitoring", The Second International Symposium on Advances in Wind and Structures (AWAS'02), Busan, Korea, August.
  44. Tao, T.Y., Wang, H. and Li, A.Q. (2016), "Stationary and nonstationary analysis on the wind characteristics of a tropical storm", Smart Struct. Syst., Int. J., 17(6), 1067-1085. https://doi.org/10.12989/sss.2016.17.6.1067
  45. Von Karman, T. (1948), "Progress in the statistical theory of turbulence", Proceedings of the National Academy of Sciences of the United States of America, 34(11), 530-539. https://dx.doi.org/10.1073%2Fpnas.34.11.530 https://doi.org/10.1073/pnas.34.11.530
  46. Xu, Y.L. and Zhan, S. (2001), "Field measurements of Di Wang Tower during Typhoon York", J. Wind Eng. Ind. Aerod., 89(1), 73-93. https://doi.org/10.1016/S0167-6105(00)00029-5
  47. Ye, X.W., Yuan, L. and Xi, P.S. (2018), "SHM-based probabilistic representation of wind properties: statistical analysis and bivariate modeling", Smart Struct. Syst., Int. J., 21(5), 591-600. https://doi.org/10.12989/sss.2018.21.5.591
  48. Zhang, J.W. and Li, Q.S. (2018), "Field measurements of wind pressures on a 600 m high skyscraper during a landfall typhoon and comparison with wind tunnel test", J. Wind Eng. Ind. Aerod., 175, 391-407. https://doi.org/10.1016/j.jweia.2018.02.012
  49. Zhu, L.D., Ding, Q.S. and Chen, W. (2006), "Wind tunnel test of aeroelastic full model of Guangzhou New TV Tower. Report", State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, China.

피인용 문헌

  1. Field measurement-based wind-induced response analysis of multi-tower building with tuned mass damper vol.32, pp.2, 2020, https://doi.org/10.12989/was.2021.32.2.143