Semi-active eddy current pendulum tuned mass damper with variable frequency and damping

  • Wang, Liangkun (Department of Disaster Mitigation for Structures, Tongji University) ;
  • Shi, Weixing (Department of Disaster Mitigation for Structures, Tongji University) ;
  • Zhou, Ying (Department of Disaster Mitigation for Structures, Tongji University) ;
  • Zhang, Quanwu (Department of Disaster Mitigation for Structures, Tongji University)
  • 투고 : 2018.11.22
  • 심사 : 2019.08.29
  • 발행 : 2020.01.25

초록

In order to protect a structure over its full life cycle, a novel tuned mass damper (TMD), the so-called semi-active eddy current pendulum tuned mass damper (SAEC-PTMD), which can retune its frequency and damping ratio in real-time, is proposed in this study. The structural instantaneous frequency is identified through a Hilbert-Huang transformation (HHT), and the SAEC-PTMD pendulum is adjusted through an HHT-based control algorithm. The eddy current damping parameters are discussed, and the relationship between effective damping coefficients and air gaps is fitted through a polynomial function. The semi-active eddy current damping can be adjusted in real-time by adjusting the air gap based on the linear-quadratic-Gaussian (LQG)-based control algorithm. To verify the vibration control effect of the SAEC-PTMD, an idealized linear primary structure equipped with an SAEC-PTMD excited by harmonic excitations and near-fault pulse-like earthquake excitations is proposed as one of the two case studies. Under strong earthquakes, structures may go into the nonlinear state, while the Bouc-Wen model has a wild application in simulating the hysteretic characteristic. Therefore, in the other case study, a nonlinear primary structure based on the Bouc-Wen model is proposed. An optimal passive TMD is used for comparison and the detuning effect, which results from the cumulative damage to primary structures, is considered. The maximum and root-mean-square (RMS) values of structural acceleration and displacement time history response, structural acceleration, and displacement response spectra are used as evaluation indices. Power analyses for one earthquake excitation are presented as an example to further study the energy dissipation effect of an SAECPTMD. The results indicate that an SAEC-PTMD performs better than an optimized passive TMD, both before and after damage occurs to the primary structure.

키워드

과제정보

연구 과제 주관 기관 : National Natural Science Foundation of China

참고문헌

  1. Casciati, F. and Ubertini, F. (2008), "Nonlinear vibration of shallow cables with semiactive tuned mass damper", Nonlinear Dyn., 53, 89-106. https://doi.org/10.1007/s11071-007-9298-y
  2. Chung, L., Wu, L., Lien, K., Chen, H. and Huang, H. (2013), "Optimal design of friction pendulum tuned mass damper with varying friction coefficient", Struct. Contr. Health Monit., 20, 544-559. https://doi.org/10.1002/stc.514
  3. Contreras, M., Pasala, D. and Nagarajaiah, S. (2014), "Adaptive length SMA pendulum smart tuned mass damper performance in the presence of real time primary system stiffness change", Smart Struct. Syst., Int. J., 13(2), 219-233. https://doi.org/10.12989/sss.2014.13.2.219
  4. Den Hartog, J.P. (1985), Mechanical Vibrations; McGraw-Hill/Dover: New York, NY, USA.
  5. Dinh, V., Biswajit. B. and Nagarajaiah, S. (2016), "Semi-active control of vibrations of spar type floating offshore wind turbines", Smart Struct. Syst., Int. J., 18(4), 683-705. https://doi.org/10.12989/sss.2016.18.4.683
  6. Domizio, M., Ambrosini, D. and Curadelli, O. (2015), "Performance of TMDs on nonlinear structures subjected to near-fault earthquakes", Smart Struct. Syst., Int. J., 16(4), 725-742. https://doi.org/10.12989/sss.2015.16.4.725
  7. Eason, R., Sun, C., Dick, A. and Nagarajaiah, S. (2013), "Attenuation of a linear oscillator using a nonlinear and a semiactive tuned mass damper in series", J. Sound Vib., 332, 154-166. https://doi.org/10.1016/j.jsv.2012.07.048
  8. Emiliano, M. and Alessandro, D. (2009), "Robust design of massuncertain rolling-pendulum TMDs for the seismic protection of buildings", Mech. Syst. Signal Pr., 23, 127-147. https://doi.org/10.1016/j.ymssp.2007.08.012
  9. Lin, G., Lin, C., Chen, B. and Soong, T. (2015), "Vibration control performance of tuned mass dampers with resettable variable stiffness", Eng. Struct., 83, 187-197. https://doi.org/10.1016/j.engstruct.2014.10.041
  10. Lu, X., Zhang, Q., Weng, D., Zhou, Z., Wang, S., Mahin, S.A., Ding, S. and Qian, F. (2017), "Improving performance of a super tall building using a new eddy-current tuned mass damper", Struct. Contr. Health Monit., 24, e1864. https://doi.org/10.1002/stc.1882
  11. Lu, Z., Huang, B., Zhang, Q. and Lu, X. (2018), "Experimental and analytical study on vibration control effects of eddy-current tuned mass dampers under seismic excitations", J. Sound Vib., 421, 153-165. https://doi.org/10.1016/j.jsv.2017.10.035
  12. Maiti, S., Bandyopadhyay, R. and Chatterjee, A. (2018), "Vibrations of an Euler-Bernoulli beam with hysteretic damping arising from dispersed frictional microcracks", J. Sound Vib., 412, 287-308. https://doi.org/10.1016/j.jsv.2017.09.025
  13. Nagarajaiah, S. (2009), "Adaptive passive, semi-active, smart tuned mass dampers: identification and control using empirical mode decomposition, Hilbert transform, and short-term Fourier transform", Struct. Contr. Health Monit., 16(7-8), 800-841. https://doi.org/10.1002/stc.349
  14. Nagarajaiah, S. and Sonmez, E. (2007), "Structures with semiactive variable stiffness single/multiple tuned mass dampers", J. Struct. Eng., 133(1), 67-77. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:1(67)
  15. Nagarajaiah, S. and Varadarajan, N. (2005), "Short time Fourier transform algorithm for wind response control of buildings with variable stiffness TMD", Eng. Struct., 27, 431-441. https://doi.org/10.1016/j.engstruct.2004.10.015
  16. Pasala, D. and Nagarajaiah, S. (2014), "Adaptive-length pendulum smart tuned mass damper using shape-memory-alloy wire for tuning period in real time", Smart Struct. Syst., Int. J., 13(2), 203-217. https://doi.org/10.12989/sss.2014.13.2.203
  17. Ramezani, M., Bathaei, A. and Zahrai, S. (2017), "Designing fuzzy systems for optimal parameters of TMDs to reduce seismic response of tall buildings", Smart Struct. Syst., Int. J., 20(1), 61-74. https://doi.org/10.12989/sss.2017.20.1.061
  18. Roffel, A., Lourenco, R., Narasimhan, S. and Yarusevych, S. (2011), "Adaptive compensation for detuning in pendulum tuned mass dampers", J. Struct. Eng., 137(2), 242-251. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000286
  19. Shi, W., Shan, J. and Lu, X. (2012), "Modal identification of Shanghai world financial center both from free and ambient vibration response", Eng. Struct., 36, 14-26. https://doi.org/10.1016/j.engstruct.2011.11.025
  20. Shi, W., Wang, L. and Lu, Z. (2018a), "Study on self-adjustable tuned mass damper with variable mass", Struct. Contr. Health Monit., 25(3), e2114. https://doi.org/10.1002/stc.2114
  21. Shi, W., Wang, L., Lu, Z. and Gao, H. (2018b), "Study on adaptive-passive and semi-active eddy current tuned mass damper with variable damping", Sustain., 10, 99. https://doi.org/10.3390/su10010099
  22. Spencer, B. and Nagarajaiah, S. (2003), "State of the art of structural control", J. Struct. Eng., 129(7), 845-856. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:7(845)
  23. Sun, C. (2018), "Semi-active control of monopile offshore wind turbines under multi-hazards", Mech. Syst. Signal Pr., 99, 285-305. https://doi.org/10.1016/j.ymssp.2017.06.016
  24. Sun, C. and Nagarajaiah, S. (2014), "Study on semi-active tuned mass damper with variable damping and stiffness under seismic excitations", Struct. Contr. Health Monit., 21(6), 890-906. https://doi.org/10.1002/stc.1620
  25. Sun, C., Eason, R., Nagarajaiah, S. and Dick, A. (2013), "Hardening Duffing oscillator attenuation using a nonlinear TMD, a semi-active TMD and multiple TMD", J. Sound Vib., 332, 674-686. https://doi.org/10.1016/j.jsv.2012.10.016
  26. Varadarajan, N. and Nagarajaiah, S. (2004), "Wind response control of building with variable stiffness tuned mass damper using empirical mode decomposition/Hilbert transform", J. Eng. Mech., 130(4), 451-458. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(451)
  27. Wang, J. and Lin, C. (2015), "Extracting parameters of TMD and primary structure from the combined system responses", Smart Struct. Syst., Int. J., 16(5), 937-960. https://doi.org/10.12989/sss.2015.16.5.937
  28. Wang, Z., Chen, Z. and Wang, J. (2012), "Feasibility study of a large-scale tuned mass damper with eddy current damping mechanism", Earthq. Eng. Eng. Vib., 11, 391-401. https://doi.org/10.1007/s11803-012-0129-x
  29. Wang, L., Shi, W. and Zhou, Y. (2018), "Study on self-adjustable variable pendulum tuned mass damper", Struct. Des. Tall Special Build., 28(1), e1561. https://doi.org/10.1002/tal.1561
  30. Wang, L., Shi, W., Li, X., Zhang, Q. and Zhou, Y. (2019), "An adaptive-passive retuning device for a pendulum tuned mass damper considering mass uncertainty and optimum frequency", Struct Control Health Monit., 26(7), e2377. https://doi.org/10.1002/stc.2377
  31. Waubke, H. and Kasess, C. (2017), "Gaussian closure technique for chain like structures with elasto-plastic elements described by the Bouc hysteresis", J. Sound Vib., 408, 73-86. https://doi.org/10.1016/j.jsv.2017.07.020

피인용 문헌