참고문헌
- Adrian, P.E. (2018), "A simple procedure to evaluate the wind-induced acceleration in tall buildings: an application to Mexico", Wind Struct., 27(5), 337-345. https://doi.org/10.12989/was.2018.27.5.337.
- Architectural Institute of Japan (2004), Guidelines for the evaluation of habitability to building vibration, Maruzen, Tokyo, Japan.
- Architectural Institute of Japan (2015), "Recommendations for loads on buildings", Maruzen, Tokyo, Japan.
- Architectural Institute of Japan (2017), "Guidebook of recommendations for loads on buildings2-wind induced response and load estimation/practical guide of CFD for wind resistant design", Maruzen, Tokyo, Japan.
- Architectural Institute of Korea (2016), "Korean building code and commentary, Kimoondang, Seoul, Republic of Korea.
- Cook, N.J. (1985), "The Designer's guide to Wind loading of Building Structure", Cambridge University Press, Shaftesbury Rd, Cambridge, U.K.
- Counihan, J. (1975), "Adiabatic atmospheric boundary layers: A review and analysis of data from the period", Atmos. Environ., 9(10), 871-905, https://doi.org/10.1016/0004-6981(75)90088-8.
- Cui, W. and Caracoglia, L. (2017), "Examination of experimental variability in HFFB testing of a tall building under multi-directional winds", J. Wind Eng. Ind. Aerod., 171, 34-49. https://doi.org/10.1016/j.jweia.2017.09.001.
- Ding, Q. and Zhu, L. (2017), "Aeroelastic model test of a 610 m-high TV tower with complex shape and structure", Wind Struct., 25(4), 361-379. https://doi.org/10.12989/was.2017.25.4.361.
- Ha, Y.C. and Kim, D.W. (2002), "The directional wind speeds for a short return period in korea evaluated by the joint probability distribution of the wind directions and speeds", J. Architect. Institute Korea Struct. Constr., 18(6), 31-38.
- Helliwell, N.C. (1971), "On wind effects on buildings and structures, wind over London", Proceedings of 3th International Conference. Tokyo, Japan.
- International Organization for Standardization (2007), "Bases for design of structures - serviceability of buildings and walkways against vibrations".
- Jacson, P.S. (1981), "On the displacement height in the logarithmic velocity profile", J. Fluid Mech., 111, 15-25. https://doi.org/10.1017/S0022112081002279.
- Japan Association for Wind Engineering (2007), Wind Engineering Handbook - Structure, Disaster Prevention, Environment, Energy, Asakura, Tokyo, Japan.
- Johann, F.A., Carlos, M.E. and Ricardo, F.L. (2015), "Wind-induced motion on tall buildings: A comfort criteria overview", J. Wind Eng. Ind. Aerod., 142, 26-42. https://doi.org/10.1016/j.jweia.2015.03.001.
- Kang, D.B. and Ko, K.N. (2018), "An application of the probability plotting positions for the lnleast method for estimating the parameters of weibull wind speed distribution", J. Korean Solar Energy Soc., 38(5), 11-25. https://doi.org/10.7836/kses.2018.38.5.011.
- Kim, S.O. (2017), "Prediction of wind damage risk based on estimation of probability distribution of daily maximum wind speed", Agr. Forest Meteorol, 19(3), 130-139. https://doi.org/10.5532/KJAFM.2017.19.3.130.
- Kwok, K.C., Hitchcock, P.A. and Burton, M.D. (2009), "Perception of vibration and occupant comfort in wind-excited tall buildings", J. Wind Eng. Ind. Aerod., 97(7-8), 368-380. https://doi.org/10.1016/j.jweia.2009.05.006.
- Lamb, S. and Kwok, K.C. (2017), "The fundamental human response to wind-induced building motion", J. Wind Eng. Ind. Aerod., 165, 79-85. https://doi.org/10.1016/j.jweia.2017.03.002.
- Murukami, S., Iwasa, Y. and Morikawa, Y. (1983), "Investigation of statistical characteristics of wind at ground level and criteria for assessing wind-induced discomfort", T. Architect. Institute Jpn., 325, 74-84. https://doi.org/10.3130/aijsaxx.325.0_74
- National Research Council Canada (2015), "National building code of Canada", Associate Committee on the National Building Code, Ottawa, Canada.
- Nist (2014), "Database-Assisted Design for Wind: Concepts, Software, and Example for High-Rise Reinforced Concrete Structures", CreateSpace Independent Publishing Platform, Scotts Valley, United States of America.
- Pagnini, L.C. and Solari, G. (1998), "Serviceability criteria for wind-induced acceleration and damping uncertainties", J. Wind Eng. Ind. Aerod., 74-76(1), 1067-1078. https://doi.org/10.1016/S0167-6105(98)00098-1.
- Shin, J.Y., Ahn, H.j., Jeong, C.S. and Ahn, J.H. (2018), "Frequency analysis of annual maximum wind speed in korea using mixture distribution", J. Korea Soc. Hazard Mitigation, 18(7), 61-69. https://doi.org/10.9798/KOSHAM.2018.18.7.61.
- Sutton, O.G. (1950), Atmospheric Turbulence, Methuen, London and Weley, U.K.
- The Wind Engineering Institute of Korea (2010), Wind-Resistant Engineering, Kimoondang, Seoul, Republic of Korea.
- Xu, A., Xie, Z.N., Fu, J.Y., Wu, J.R. and Tuan, A. (2014), "Evaluation of wind loads on super-tall buildings from field-measured wind-induced acceleration response", Struct. Des. Tall Spec. Build., 23(9), 641-663. https://doi.org/10.1002/tal.1065.
- You, J.Y., Chae, M.J. and You, K.P. (2018), "Assessment of the wind environment in apartment complexes having piloti on the lower levels", J. Architect. Institute Korea, 20(1), 181-188. https://www.earticle.net/Article/A326138.
- Zhang, Y., Habashi, W.G. and Khurram, R.A. (2015), "Predicting wind-induced vibrations of high-rise buildings using unsteady CFD and modal analysis", J. Wind Eng. Ind. Aerod., 136, 165-179. https://doi.org/10.1016/j.jweia.2014.11.008.