References
- Choi, Y.H. and Kweon, J.H.(2005). Investigation of Membrane Fouling in Microfiltration by Characterization of Flocculent Aggregates, J. Korean Soc. Environ. Eng., 28(3), 337-344.
- Gregory, J. (1998). Colloidal interactions, Matel. Sci. Forum, 25-26, 125-144. https://doi.org/10.4028/www.scientific.net/MSF.25-26.125
- Gregory, J. and Duan, J. (2001). Hydrolysing metal salts as coagulants, Pure Appl. Chem., 73(12), 2017-2026. https://doi.org/10.1351/pac200173122017
- Guigui, C., Rouch, J.C., Durand-Bourlier, L., Bonnelye, V. and Aptel, P. (2002). Impact of coagulation conditions on the in-line coagulation/UF process for drinking water production, Desalination, 147, 95-100. https://doi.org/10.1016/S0011-9164(02)00582-9
- Ha, G.R., Kim, H.S., Oh. Y.G., Kim, C.H., Quang, C.X.. Tam, P.T.T. and Lee, Y. H. (2007). Determination of optimal coagulant dosage in pre-coagulation/submerged MF for reducing membrane fouling, J. Korean Soc. Environ. Eng., 2007(5), 2087-2091.
- James, C.V., Mark, A.T. and Uday, G.K. (1995). The use of membrane filtration in conjuction with coagulation processes for improved NOM removal, Desalination, 102, 57-61. https://doi.org/10.1016/0011-9164(95)00041-Y
- Jin, Y.C., Choi, Y.H. and Kweon, J.H. (2011). Impact of characteristics of polymeric Al coagulants PACl and alum on membrane flux and fouling of microfiltration, J. Korean Soc. Water Wastewater, 25(2), 231-240.
- Jung, C.W., Shim, H.S. and Sohn, I.S. (2007). Effect of metal salt coagulant on membrane fouling during coagulation-UF membrane process, Korean Chem. Eng. Res., 45(5), 523-528.
- Kang, J.S. Park, S.G., Lee, J.J. and Kim, H.S. (2018). Effects of membrane fouling formation by feed water quality and membrane flux in water treatment process using ceramic membrane, J. Korean Soc. Water Wastewater, 32(2), 77-87. https://doi.org/10.11001/jksww.2018.32.2.077
- Kang, J. S., Park, S.G., Song, J.Y., Jeong, A.Y., Lee, J.J. and Kim, H.S. (2017). Evaluation of membrane fouling characteristics due to manganese and chemical cleaning efficiency in microfiltration membrane process, J. Korean Soc. Water Wastewater, 31(6), 539-549. https://doi.org/10.11001/jksww.2017.31.6.539
- Kim, J.H., Mun, B.S., Jang, H.J., Kim, J.H., and Kim, B.S.(2013). Increase of recovery ratio by two stage membrane process(the pressurized PVDF membrane followed by submerged PE membrane), Membr. J., 23(1), 45-53.
- Korea Environment Corporation. (2017). Development of membrane filtration water treatment facility technical inspection manual.
- Lee, B.G., Lee, K.S., Lee, K.K. and Kang, S.H. (2007). Characteristics of long term Period MF Membrane Pilot Plant Operation for Replacement of Sand Filtration, J. Korean Soc. Water Environ., B-3, 163-171.
- Lee, B.H., Kim, J.G. and Lee, K.H. (2000). Membrane fouling by iron and manganese in hollow-fiber microfiltration, J. Korean Soc. Civ. Eng., 7, 591-597.
- Lee, J.D., Lee, S.H., Jo, M.H., Park, P.K., Lee, C.H. and Kwak, J.W. (2000). Effect of coagulation conditions on membrane filtration characteristics in coagulation-microfiltration process for water treatment, Environ. Sci. Technol., 34, 17, 3780-3788. https://doi.org/10.1021/es9907461
- Lee, S.H., Kweon, J.H., Choi, Y.H. and Ahn, K.H. (2004). Effects of characteristics of flocculant aggregates on membrane fouling in microfiltration with coagulation pretreatment, J. Korean Soc. Water Wastewater, 18(6), 785-793.
- Lee, Y.T. and Oh, J.K. (1999). A study on the optimization of process and operation condition for membrane system in tap water treatment, Membr. J., 9(4), 193-201.
- Ministry of Environment. (2014). The study for applicability evaluation and the developmental direction of membrane water treatment facilities.
- Pernitsky, D.J. and Edzwald, J.K. (2003). Solubility of polyaluminuium coagulants, J. Water Supply Res. Technol., 52(6), 395-406. https://doi.org/10.2166/aqua.2003.0036
- Song, Y.K., Jung, C.W., Hwangbo, B.H. and Shon, I.S. (2001). Characteristics of Al(lll) hydrolysis species distribution on coagulation process, Korean Chem. Eng. Res., 44(5), 547-554.