DOI QR코드

DOI QR Code

Fire Resistant Performance of High Strength RC Member with Fire Resistant Panel using PP Fiber and Steel Fiber

PP섬유 및 강섬유를 혼입한 내화패널을 부착한 고강도 철근콘크리트 부재의 내화성능 평가 및 개선

  • Received : 2018.04.29
  • Accepted : 2020.05.28
  • Published : 2020.12.30

Abstract

In this study, the fire resistant panels using blast furnace slag and fiber(pp, steel, hybrid) was constructed and tested to prevent the spalling of high strength concrete. Structural performance of reinforced concrete beams with fire resistant panel was evaluated such as load-displacement, failure mode, maximum load carrying capacity, and ductility, after exposure to fire test. In Specimen BSS-F, maximum load carrying capacity was decreased by 21% in comparison with specimen BSS. It was also happened shear failure at the final tests. Test results showed that Specimen BSBPP-F series, BSBS-F series, and BSBPS-F series was increased the maximum load carrying capacity by 10~28% and the ductility capacity by 59~363% respectively in comparison with the Specimen BSS-F. Specimen with the fire resistant panel showed stable behavior and it was found that maximum load carrying capacity was increased.

Keywords

Acknowledgement

본 연구는 2016년도 중소벤처기업부의 기술개발사업 지원에 의한 연구임. (과제번호: C0397935, 2015R1C1A1A02037741)

References

  1. Han, C. G., Chae, M. S., Lee, B. Y., & Yang, S. H. (1999). Study on the Spalling Resistance of High-Performance Cement Mortar with Polypropylene Fiber Content, Journal of the Architectural Institute of Korea, 15(12), 89-96
  2. Ju, M. K., Park, C. W., Oh, J. H., Seo, S. G., & Shim, J.W. (2016). Investigation of Material Characteristics of Reinforced Concrete Beam After Exposure to Fire Test, Journal of the Korea Institute for Structural Maintenance and Inspection, 20(3), 33-41 https://doi.org/10.11112/jksmi.2016.20.3.033
  3. Lim, J. W., Seo, S. Y., & Song, S. K. (2017). Experiment for the Improvement of Fire Resistance Capacity of Reinforced Concrete Flexural Member Strengthened with Carbon Fiber Reinforced Polymer, 33(12), 19-27 https://doi.org/10.5659/JAIK_SC.2017.33.12.19
  4. Ha, G. J. (2010). Improvement and Evaluation of Repair-Retrofit Performance of Reinforced Concrete Beam using High Ductile Fiber-Reinforced Mortar with Ground Granulated Blast Furnace Slag, Journal of Regional Association of Architectural Institute of Korea, 12(4), 261-270
  5. Youm, K. S., & Jeon, H. G. (2010). Fire Resistance Performance of High Strength Concrete Columns with Fireproof Gypsum Board, Journal of the Korea Concrete Institute, 22(2), 229-235 https://doi.org/10.4334/JKCI.2010.22.2.229
  6. Han, C. G., Ham, M. C., Kim, W. K., & Lee, J. S. (2009). Effect of Admixture Types and PP Fiber on the Development of Spalling Resistance of High Strength Concrete, Journal of the Architectural Institute of Korea, 25(11), 105-112
  7. Concrete Structure Design Specification (2012). Korea Concrete Institute.
  8. ACI Committee 216. (2017). Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies, American Concrete Institute
  9. Ministry of Land, Infrastructure and Transport (2012). Standard for Fire Resistance Structures (No. 2012-625).
  10. Concrete Center (2004). Concrete and Fire, The Concrete Center